Haemodynamic changes with varying chest compression rates in asphyxiated piglets

被引:10
作者
Bruckner, Marlies [1 ,2 ]
Neset, Mattias [2 ,3 ]
O'Reilly, Megan [2 ,4 ]
Lee, Tze-Fun [2 ]
Cheung, Po-Yin [2 ,4 ]
Schmoelzer, Georg M. [2 ,4 ]
机构
[1] Med Univ Graz, Dept Pediat & Adolescent Med, Graz, Austria
[2] Univ Alberta, Fac Engn, Ctr Studies Asphyxia & Resuscitat, Neonatal Res Unit, Edmonton, AB, Canada
[3] Univ Alberta, Edmonton, AB, Canada
[4] Univ Alberta, Dept Pediat, Edmonton, AB, Canada
来源
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION | 2023年 / 108卷 / 02期
关键词
resuscitation; neonatology; CARDIOPULMONARY-RESUSCITATION;
D O I
10.1136/archdischild-2021-323271
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background Current neonatal resuscitation guidelines recommend that chest compressions (CCs) be delivered at a rate of 90/min. The aim of the study was to investigate the haemodynamic effects of different CC rates in a neonatal piglet model. Methods Six asphyxiated piglets were randomised to CC with rates of 60/min, 90/min, 120/min, 150/min and 180/min for 1 min at each rate. CCs superimposed with sustained inflations were performed with an automated CC machine. Results Six newborn piglets (age 0-3 days, weight 2.0-2.3 kg) were included in the study. Overall, there was a gradual increase in stroke volume, minimum and maximum rate of left ventricle pressure change (dp/dt(min) and dp/dt(max)), and carotid blood flow until CC rate of 150/min, with a level-off effect at a CC rate of 180/min. However, cardiac output continued to increase with the highest being at a CC rate of 180/min. Conclusion Rate of CC was associated with changes in haemodynamic parameters during cardiopulmonary resuscitation. CC rate of 150-180/min during CC resulted in the highest cardiac output and arterial blood pressure. In this paper, the authors found that incremental increases in the rate of chest compressions up to 180/min improved cardiac output in asphyxiated piglets receiving cardiopulmonary resuscitation with sustained inflations.
引用
收藏
页码:200 / 203
页数:4
相关论文
共 6 条
[1]   Neonatal CPR: Room at the top-A mathematical study of optimal chest compression frequency versus body size [J].
Babbs, Charles F. ;
Meyer, Andrew ;
Nadkarni, Vinay .
RESUSCITATION, 2009, 80 (11) :1280-1284
[2]   Effects of varying chest compression depths on carotid blood flow and blood pressure in asphyxiated piglets [J].
Bruckner, Marlies ;
O'Reilly, Megan ;
Lee, Tze-Fun ;
Neset, Mattias ;
Cheung, Po-Yin ;
Schmoelzer, Georg M. .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2021, 106 (05) :F553-F556
[3]   CARDIAC-OUTPUT DURING CARDIOPULMONARY RESUSCITATION AT VARIOUS COMPRESSION RATES AND DURATIONS [J].
FITZGERALD, KR ;
BABBS, CF ;
FRISSORA, HA ;
DAVIS, RW ;
SILVER, DI .
AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 241 (03) :H442-H448
[4]   Cardiopulmonary Resuscitation With Chest Compressions During Sustained Inflations A New Technique of Neonatal Resuscitation That Improves Recovery and Survival in a Neonatal Porcine Model [J].
Schmoelzer, Georg M. ;
O'Reilly, Megan ;
LaBossiere, Joseph ;
Lee, Tze-Fun ;
Cowan, Shaun ;
Qin, Sharon ;
Bigam, David L. ;
Cheung, Po-Yin .
CIRCULATION, 2013, 128 (23) :2495-2503
[5]   Chest Compressions During Sustained Inflation During Cardiopulmonary Resuscitation in Newborn Infants Translating Evidence From Animal Studies to the Bedside [J].
Schmolzer, Georg M. .
JACC-BASIC TO TRANSLATIONAL SCIENCE, 2019, 4 (01) :116-121
[6]   Neonatal Life Support 2020 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations [J].
Wyckoff, Myra H. ;
Wyllie, Jonathan ;
Aziz, Khalid ;
de Almeida, Maria Fernanda ;
Fabres, Jorge ;
Fawke, Joe ;
Guinsburg, Ruth ;
Hosono, Shigeharu ;
Isayama, Tetsuya ;
Kapadia, Vishal S. ;
Kim, Han-Suk ;
Liley, Helen G. ;
McKinlay, Christopher J. D. ;
Mildenhall, Lindsay ;
Perlman, Jeffrey M. ;
Rabi, Yacov ;
Roehr, Charles C. ;
Schmolzer, Georg M. ;
Szyld, Edgardo ;
Trevisanuto, Daniele ;
Velaphi, Sithembiso ;
Weiner, Gary M. .
CIRCULATION, 2020, 142 :S185-S221