An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of carbamazepine in human serum and plasma

被引:1
作者
Schierscher, Tobias [2 ]
Salzmann, Linda [2 ]
Singh, Neeraj [3 ]
Bachmann, Martina [3 ]
Bauland, Friederike [4 ]
Geistanger, Andrea [3 ]
Risch, Lorenz [2 ]
Geletneky, Christian [3 ]
Seger, Christoph [2 ]
Taibon, Judith [1 ]
机构
[1] Roche Diagnost GmbH, Nonnenwald 2, D-82377 Penzberg, Germany
[2] Dr Risch Ostschweiz AG, Buchs, Switzerland
[3] Roche Diagnost GmbH, Penzberg, Germany
[4] Chrestos Concept GmbH & Co KG, Essen, Germany
关键词
carbamazepine; ID-LC-MS/MS; qNMR; reference measurement procedure; traceability; standardization; 10 ANTIEPILEPTIC DRUGS; NMR QNMR SPECTROSCOPY; ABSOLUTE CONTENT; CARBAMAZEPINE-10,11-EPOXIDE; MS; METABOLITES; SAMPLES;
D O I
10.1515/cclm-2023-0943
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: An isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) was developed and validated to accurately measure serum and plasma concentrations of carbamazepine. Methods: Quantitative nuclear magnetic resonance (qNMR) spectroscopy was used to determine the absolute content of the reference material, ensuring its traceability to SI units. The separation of carbamazepine from potential interferences, whether known or unknown, was achieved using a C18 column. A protein precipitation protocol followed by a high dilution step was established for sample preparation. Assay validation and determination of measurement uncertainty were performed in accordance with the guidelines of the Clinical and Laboratory Standards Institute, the International Conference on Harmonization (ICH), and the Guide to the Expression of Uncertainty in Measurement (GUM). In order to demonstrate equivalence to the already existing RMP a method comparison study was performed. Results: The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of carbamazepine within the range of 0.800-18.0 mu g/mL. Intermediate precision and repeatability (n=60 measurements) was found to be <1.6 % and <1.3 % over all concentration levels and independent from the matrix. The relative mean bias ranged from -0.1 to 0.6 % for native serum and from -0.3 to -0.1 % for Li-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment were found to be <1.8 % and <1.3 %, respectively. Method comparison showed a good agreement between the Joint Committee of Traceability in Laboratory Medicine (JCTLM) listed RMP and the candidate RMP resulting in a Passing-Bablok regression equation with a slope of 1.01 and an intercept of -0.01. The bias in the patient cohort was found to be 0.9 %. Conclusions: We present a novel LC-MS/MS-based candidate RMP for carbamazepine in human serum and plasma which provides a traceable and reliable platform for the standardization of routine assays and evaluation of clinically relevant samples.
引用
收藏
页码:1301 / 1313
页数:13
相关论文
共 50 条
[21]   Isotope-dilution-LC-MS/MS candidate reference measurement procedure for cefepime in human serum [J].
Schaeffler, Judith ;
Vogeser, Michael ;
Habler, Katharina .
JOURNAL OF MASS SPECTROMETRY AND ADVANCES IN THE CLINICAL LAB, 2024, 33 :43-48
[22]   Quantification of cyclizine and norcyclizine in human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) [J].
Jensen, Berit Packert ;
Vella-Brincat, Jane Winifred Ann ;
Begg, Evan James .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (9-10) :605-609
[23]   Measurement of dehydroepiandrosterone sulphate (DHEAS): A comparison of Isotope-Dilution Liquid Chromatography Tandem Mass Spectrometry (ID-LC-MS/MS) and seven currently available immunoassays [J].
Buttler, Rahel M. ;
Kruit, Adrian ;
Blankenstein, Marinus A. ;
Heijboer, Annemieke C. .
CLINICA CHIMICA ACTA, 2013, 424 :22-26
[24]   Evaluation of a bracketing calibration-based isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for 17α-hydroxyprogesterone in human plasma [J].
Zhang, Qiaoxuan ;
Zhang, Lu ;
Lin, Haibiao ;
Cai, Zhiliang ;
Yan, Jun ;
Wang, Qiqin ;
Han, Liqiao ;
Wang, Jianbing ;
Ke, Peifeng ;
Zhuang, Junhua ;
Huang, Xianzhang .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (27) :7095-7104
[25]   Evaluation and clinical application of a bracketing calibration-based isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for serum theophylline [J].
Du, Yuanyuan ;
Yan, Qiaofang ;
Zhan, Min ;
Zhang, Qiaoxuan ;
Huang, Di ;
Zhang, Pengwei ;
Yan, Jun ;
Wang, Jianbing ;
Huang, Xianzhang ;
Han, Liqiao .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (22) :4897-4906
[26]   An isotope dilution LC-MS/MS-based candidate reference method for the quantification of androstenedione in human serum and plasma [J].
Gradl, Katrin ;
Taibon, Judith ;
Singh, Neeraj ;
Albrecht, Eva ;
Geistanger, Andrea ;
Pongratz, Stephan ;
Hutzler, Stefan ;
Mayer, Magdalena ;
Kleinschmidt, Christine ;
Geletneky, Christian ;
Hofmann, Verena ;
Koeppl, Daniel ;
Rauh, Manfred ;
Kobold, Uwe .
CLINICAL MASS SPECTROMETRY, 2020, 16 :1-10
[27]   ESTIMATION OF MELOXICAM IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY (LC-MS/MS) [J].
Ganesh, Mani ;
Hemalatha, Pushparaj ;
Peng, Mei Mei ;
Sakthimanigandan, Kalaimani ;
Jang, Hyun Tae .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2013, 36 (07) :867-880
[28]   Candidate reference measurement procedure for determination of urea in serum by liquid chromatography-tandem mass spectrometry [J].
Han, Liqiao ;
Huang, Xiaoting ;
Zhang, Lu ;
Zhang, Qiaoxuan ;
Wang, Jianbing ;
Lin, Haibiao ;
Yan, Jun ;
Zhuang, Junhua ;
Huang, Xianzhang .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 162 :124-129
[29]   Clinical application of an optimized reference measurement procedure for serum digoxin using bracketing calibration method by ID-LC-MS/MS [J].
Yan, Qiaofang ;
Huang, Fei ;
Wang, Chuyang ;
Zhan, Min ;
Zhang, Qiaoxuan ;
Huang, Di ;
Yan, Jun ;
Lin, Haibiao ;
Huang, Xianzhang ;
Han, Liqiao .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (29) :6909-6918
[30]   Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry [J].
Susan S.-C. Tai ;
Bei Xu ;
Michael J. Welch ;
Karen W. Phinney .
Analytical and Bioanalytical Chemistry, 2007, 388 :1087-1094