An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of carbamazepine in human serum and plasma

被引:1
|
作者
Schierscher, Tobias [2 ]
Salzmann, Linda [2 ]
Singh, Neeraj [3 ]
Bachmann, Martina [3 ]
Bauland, Friederike [4 ]
Geistanger, Andrea [3 ]
Risch, Lorenz [2 ]
Geletneky, Christian [3 ]
Seger, Christoph [2 ]
Taibon, Judith [1 ]
机构
[1] Roche Diagnost GmbH, Nonnenwald 2, D-82377 Penzberg, Germany
[2] Dr Risch Ostschweiz AG, Buchs, Switzerland
[3] Roche Diagnost GmbH, Penzberg, Germany
[4] Chrestos Concept GmbH & Co KG, Essen, Germany
关键词
carbamazepine; ID-LC-MS/MS; qNMR; reference measurement procedure; traceability; standardization; 10 ANTIEPILEPTIC DRUGS; NMR QNMR SPECTROSCOPY; ABSOLUTE CONTENT; CARBAMAZEPINE-10,11-EPOXIDE; MS; METABOLITES; SAMPLES;
D O I
10.1515/cclm-2023-0943
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: An isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) was developed and validated to accurately measure serum and plasma concentrations of carbamazepine. Methods: Quantitative nuclear magnetic resonance (qNMR) spectroscopy was used to determine the absolute content of the reference material, ensuring its traceability to SI units. The separation of carbamazepine from potential interferences, whether known or unknown, was achieved using a C18 column. A protein precipitation protocol followed by a high dilution step was established for sample preparation. Assay validation and determination of measurement uncertainty were performed in accordance with the guidelines of the Clinical and Laboratory Standards Institute, the International Conference on Harmonization (ICH), and the Guide to the Expression of Uncertainty in Measurement (GUM). In order to demonstrate equivalence to the already existing RMP a method comparison study was performed. Results: The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of carbamazepine within the range of 0.800-18.0 mu g/mL. Intermediate precision and repeatability (n=60 measurements) was found to be <1.6 % and <1.3 % over all concentration levels and independent from the matrix. The relative mean bias ranged from -0.1 to 0.6 % for native serum and from -0.3 to -0.1 % for Li-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment were found to be <1.8 % and <1.3 %, respectively. Method comparison showed a good agreement between the Joint Committee of Traceability in Laboratory Medicine (JCTLM) listed RMP and the candidate RMP resulting in a Passing-Bablok regression equation with a slope of 1.01 and an intercept of -0.01. The bias in the patient cohort was found to be 0.9 %. Conclusions: We present a novel LC-MS/MS-based candidate RMP for carbamazepine in human serum and plasma which provides a traceable and reliable platform for the standardization of routine assays and evaluation of clinically relevant samples.
引用
收藏
页码:1301 / 1313
页数:13
相关论文
共 50 条
  • [1] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of levetiracetam in human serum and plasma
    Kobel, Anja
    Schierscher, Tobias
    Singh, Neeraj
    Salzmann, Linda
    Liesch, Franziska
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1967 - 1977
  • [2] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of topiramate in human serum and plasma
    Salzmann, Linda
    Spescha, Tino
    Singh, Neeraj
    Kobel, Anja
    Fischer, Vanessa
    Schierscher, Tobias
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1942 - 1954
  • [3] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of zonisamide in human serum and plasma
    Schierscher, Tobias
    Salzmann, Linda
    Singh, Neeraj
    Wild, Janik
    Fischer, Vanessa
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (07) : 1288 - 1300
  • [4] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of gabapentin in human serum and plasma
    Salzmann, Linda
    Wild, Janik
    Singh, Neeraj
    Schierscher, Tobias
    Liesch, Franziska
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1955 - 1966
  • [5] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of primidone in human serum and plasma
    Schierscher, Tobias
    Salzmann, Linda
    Singh, Neeraj
    Fischer, Vanessa
    Kobel, Anja
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (07) : 1327 - 1338
  • [6] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of lamotrigine in human serum and plasma
    Salzmann, Linda
    Spescha, Tino
    Singh, Neeraj
    Schierscher, Tobias
    Bachmann, Martina
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1930 - 1941
  • [7] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of phenobarbital in human serum and plasma
    Schierscher, Tobias
    Salzmann, Linda
    Singh, Neeraj
    Bachmann, Martina
    Kobel, Anja
    Wild, Janik
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (07) : 1314 - 1326
  • [8] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of aldosterone in human serum and plasma
    Taibon, Judith
    Santner, Tobias
    Singh, Neeraj
    Ibrahim, Sara Cheikh
    Babitzki, Galina
    Koeppl, Daniel
    Gaudl, Alexander
    Geistanger, Andrea
    Ceglarek, Uta
    Rauh, Manfred
    Geletneky, Christian
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1902 - 1916
  • [9] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of methotrexate in human serum and plasma
    Engel, Anett
    Ruhe, Lena
    Singh, Neeraj
    Wright, Jo Anne
    Liesch, Franziska
    Bauland, Friederike
    Ostermann, Annika I. I.
    Sumalowitsch, Tamara
    Schweinsberg, Vincent J. T.
    Geistanger, Andrea
    Hegel, Johannes Kolja
    Geletneky, Christian
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1917 - 1929
  • [10] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of carbamazepine-10,11-epoxide in human serum and plasma
    Schierscher, Tobias
    Singh, Neeraj
    Kobel, Anja
    Wild, Janik
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (07) : 1339 - 1351