Breast cancer screening with digital breast tomosynthesis: Is independent double reading still required?

被引:2
作者
Weigel, Stefanie [1 ,2 ,3 ,6 ,7 ]
Hense, Hans-Werner [4 ]
Weyer-Elberich, Veronika [5 ]
Gerss, Joachim [5 ]
Heindel, Walter [1 ]
机构
[1] Univ Munster, Clin Radiol, Munster, Germany
[2] Univ Munster, Reference Ctr Mammog Munster, Munster, Germany
[3] Univ Hosp Munster, Munster, Germany
[4] Univ Munster, Inst Epidemiol & Social Med, Munster, Germany
[5] Univ Munster, Inst Biostat & Clin Res, Munster, Germany
[6] Univ Munster, Clin Radiol, Fac Med, Albert Schweitzer Campus 1,Bldg A1, D-48149 Munster, Germany
[7] Univ Munster, Reference Ctr Mammog Munster, Fac Med, Albert Schweitzer Campus 1,Bldg A1, D-48149 Munster, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2024年 / 196卷 / 08期
关键词
breast cancer; digital breast tomosynthesis; independant double reading; screening; MAMMOGRAPHY;
D O I
10.1055/a-2216-1109
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The European guidelines recommend independent double reading in mammography screening programs. The prospective randomized controlled trial TOSYMA tested the superiority of digital breast tomosynthesis and synthetic mammography (DBT+SM) over digital mammography (DM) for invasive breast cancer detection. This sub-analysis compares the true-positive readings of screening-detected breast cancers resulting from independent double readings in the two trial arms. Materials and methods: The 1:1 randomized TOSYMA trial was executed in 17 screening units between 07/2018 and 12/2020. This sub-analysis included 49,762 women in the test arm (DBT+SM) and 49,796 women in the control arm (DM). The true-positive reading results (invasive breast cancers and ductal carcinoma in situ) from 83 readers were determined and merged in a double reading result. Results: DBT+SM screening detected 416 women with breast cancer and DM screening detected 306. Double readings of DBT+SM examinations led to a single true-positive together with a single false-negative result in 26.9 % of cancer cases (112/416), and in 22.2 % of cases (68/306) in the DM examinations. The cancer detection rate with discordant reading results was 2.3 per 1,000 women screened with DBT+SM and 1.4 per 1,000 with DM. Discordant reading results occurred most often for invasive breast cancers [DBT+SM 75.9 % (85/112), DM 67.6 % (46/68)], category T1 [DBT+SM 67.9 % (76/112), DM 55.9 % (38/68)], and category 4a [DBT+SM: 67.6 % (73/112); DM: 84.6 % (55/68)]. Conclusion: The higher breast cancer detection rate with DBT screening includes a relevant percentage of breast cancers that were only detected by one reader in an independent double reading. As in digital mammography, independent double reading continues to be justified in screening with digital breast tomosynthesis.
引用
收藏
页码:834 / 842
页数:9
相关论文
共 22 条
  • [1] Digital Breast Tomosynthesis: Concepts and Clinical Practice
    Chong, Alice
    Weinstein, Susan P.
    McDonald, Elizabeth S.
    Conant, Emily F.
    [J]. RADIOLOGY, 2019, 292 (01) : 1 - 14
  • [2] Ciatto S, 1995, J Med Screen, V2, P99
  • [3] D'Orsi C.J., 2003, Breast imaging reporting and data system (BI-RADS) breast imaging atlas
  • [4] Breast cancer screening with digital breast tomosynthesis: comparison of different reading strategies implementing artificial intelligence
    Dahlblom, Victor
    Dustler, Magnus
    Tingberg, Anders
    Zackrisson, Sophia
    [J]. EUROPEAN RADIOLOGY, 2023, 33 (05) : 3754 - 3765
  • [5] DOrsi CJ, 2013, ACR BIRADS ATLAS BRE
  • [6] Digital breast tomosynthesis plus synthesised mammography versus digital screening mammography for the detection of invasive breast cancer (TOSYMA): a multicentre, open-label, randomised, controlled, superiority trial
    Heindel, Walter
    Weigel, Stefanie
    Gerss, Joachim
    Hense, Hans-Werner
    Sommer, Alexander
    Krischke, Miriam
    Kerschke, Laura
    [J]. LANCET ONCOLOGY, 2022, 23 (05) : 601 - 611
  • [7] Heindel W, 2021, RADIOLOGE, V61, P126, DOI 10.1007/s00117-020-00803-1
  • [8] Screening-detected Breast Cancers: Discordant Independent Double Reading in a Population-based Screening Program
    Hofvind, Solveig
    Geller, Berta M.
    Rosenberg, Robert D.
    Skaane, Per
    [J]. RADIOLOGY, 2009, 253 (03) : 652 - 660
  • [9] Artificial intelligence-supported screen reading versus standard double reading in the Mammography Screening with Artificial Intelligence trial (MASAI): a clinical safety analysis of a randomised, controlled, non-inferiority, single- blinded, screening accuracy study
    Lang, Kristina
    Josefsson, Viktoria
    Larsson, Anna-Maria
    Larsson, Stefan
    Hogberg, Charlotte
    Sartor, Hanna
    Hofvind, Solveig
    Andersson, Ingvar
    Rosso, Aldana
    [J]. LANCET ONCOLOGY, 2023, 24 (08) : 936 - 944
  • [10] Breast-Cancer Screening - Viewpoint of the IARC Working Group
    Lauby-Secretan, Beatrice
    Scoccianti, Chiara
    Loomis, Dana
    Benbrahim-Tallaa, Lamia
    Bouvard, Veronique
    Bianchini, Franca
    Straif, Kurt
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2015, 372 (24) : 2353 - 2358