Three-dimensional Motion Analysis of Sacroiliac Joint Mobility: A Reliability Study

被引:0
作者
Parchekouhi, Ahmad Bahramian [1 ]
Karimi, Noureddin [2 ]
Yousefi, Mohammad [3 ]
Ghomsheh, Farhad Tabatabai [4 ]
Rahnama, Leila [5 ]
机构
[1] Univ Social Welf & Rehabil Sci, Physiotherapy, Tehran, Iran
[2] Univ Social Welf & Rehabil Sci, Dept Physiotherapy, Tehran, Iran
[3] Univ Birjand, Fac Sport Sci, Sports Biomech, Birjand, Iran
[4] Univ Social Welf & Rehabil Sci, Pediat Neurorehabil Res, Ergon Dept, Tehran, Iran
[5] Calif State Univ Los Angeles, Sch Kinesiol, Los Angeles, CA 90032 USA
关键词
3D motion analysis; Forward flexion test; Reliability; Sacroiliac joint; MOVEMENTS; ACCURACY; VALIDITY; SYSTEM; TESTS;
D O I
10.32592/ircmj.2023.25.1.2440
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Sacroiliac joint (SIJ) movement has been investigated in many studies using a motion analysis system; however, the reliability of this method has not been well defined yet. Objectives: This study aimed to investigate the reliability of measuring the three-dimensional (3D) movement of the SIJ through the motion analysis system. Methods: A total of 10 healthy participants performed three forward flexions from a standing position twice in one session with an interval of 30 minutes. The movements were captured by the VICON motion analysis system, and the motion of the sacrum relative to each innominate was estimated in three plans of movement. The test-retest reliability was calculated with the average of three trials using the intraclass correlation coefficient (ICC) with a 95% confidence interval (CI). Results: The measurements demonstrated good to excellent reliability (ICC: from 0.61 to 0.97) that was achieved for the SIJ motion variables. Conclusion: The outcomes of this study showed that the 3D motion analysis can be used for the evaluation of SIJ mobility due to its acceptable reliability.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Reliability of Cusp Angulation Using Three-Dimensional Digital Models: A Preliminary In Vitro Study
    Liu, Xinggang
    Chen, Xiaoxian
    METHODS OF INFORMATION IN MEDICINE, 2022, 61 (03/04) : 90 - 98
  • [42] Biomechanics of the Cricoarytenoid Joint: Three-Dimensional Imaging and Vector Analysis
    Storck, Claudio
    Juergens, Philipp
    Fischer, Claude
    Wolfensberger, Markus
    Honegger, Flurin
    Sorantin, Erich
    Friedrich, Gerhard
    Gugatschka, Markus
    JOURNAL OF VOICE, 2011, 25 (04) : 406 - 410
  • [43] Validity and reliability of smartphone applications for measurement of hip rotation, compared with three‐dimensional motion analysis
    Phob Ganokroj
    Nuchanun Sompornpanich
    Pichitpol Kerdsomnuek
    Bavornrat Vanadurongwan
    Pisit Lertwanich
    BMC Musculoskeletal Disorders, 22
  • [44] Can the reliability of three-dimensional running kinematics be improved using functional joint methodology?
    Pohl, Michael B.
    Lloyd, Chandra
    Ferber, Reed
    GAIT & POSTURE, 2010, 32 (04) : 559 - 563
  • [45] Contribution of the three-dimensional model to the reliability allocation of multiphase systems
    Saadi, Saadia
    Djebabra, Mebarek
    Roudies, Ounsa
    Boulagouas, Wafa
    INTERNATIONAL JOURNAL OF QUALITY & RELIABILITY MANAGEMENT, 2019, 36 (07) : 1038 - 1052
  • [46] Multibracket appliance: impression defaults and their reduction by blocking-out - a three-dimensional study
    Wriedt, Susanne
    Foersch, Moritz
    Muhle, Jan Daniel
    Schmidtmann, Irene
    Wehrbein, Heinrich
    CLINICAL ORAL INVESTIGATIONS, 2016, 20 (02) : 365 - 372
  • [47] Assessment of Biomechanical Changes After Sacroiliac Joint Fusion by Application of the 3-Dimensional Motion Analysis Technique
    Jeong, Je Hoon
    Leasure, Jeremi M.
    Park, Jon
    WORLD NEUROSURGERY, 2018, 117 : E538 - E543
  • [48] The accuracy and reliability of 3D printed aortic templates: a comprehensive three-dimensional analysis
    Rynio, Pawel
    Wojtun, Maciej
    Wojcik, Lukasz
    Kawa, Milosz
    Falkowski, Aleksander
    Gutowski, Piotr
    Kazimierczak, Arkadiusz
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (02) : 1385 - 1396
  • [49] The Reliability of Two- and Three-Dimensional Cephalometric Measurements: A CBCT Study
    Li, Chenshuang
    Teixeira, Hellen
    Tanna, Nipul
    Zheng, Zhong
    Chen, Stephanie Hsiang Yi
    Zou, Min
    Chung, Chun-Hsi
    DIAGNOSTICS, 2021, 11 (12)
  • [50] A Photogrammetric Method for the Measurement of Three-Dimensional Cervical Range of Motion
    Li, Rui
    Jiang, Qi
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (02) : 685 - 695