Three-dimensional Motion Analysis of Sacroiliac Joint Mobility: A Reliability Study

被引:0
|
作者
Parchekouhi, Ahmad Bahramian [1 ]
Karimi, Noureddin [2 ]
Yousefi, Mohammad [3 ]
Ghomsheh, Farhad Tabatabai [4 ]
Rahnama, Leila [5 ]
机构
[1] Univ Social Welf & Rehabil Sci, Physiotherapy, Tehran, Iran
[2] Univ Social Welf & Rehabil Sci, Dept Physiotherapy, Tehran, Iran
[3] Univ Birjand, Fac Sport Sci, Sports Biomech, Birjand, Iran
[4] Univ Social Welf & Rehabil Sci, Pediat Neurorehabil Res, Ergon Dept, Tehran, Iran
[5] Calif State Univ Los Angeles, Sch Kinesiol, Los Angeles, CA 90032 USA
关键词
3D motion analysis; Forward flexion test; Reliability; Sacroiliac joint; MOVEMENTS; ACCURACY; VALIDITY; SYSTEM; TESTS;
D O I
10.32592/ircmj.2023.25.1.2440
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Sacroiliac joint (SIJ) movement has been investigated in many studies using a motion analysis system; however, the reliability of this method has not been well defined yet. Objectives: This study aimed to investigate the reliability of measuring the three-dimensional (3D) movement of the SIJ through the motion analysis system. Methods: A total of 10 healthy participants performed three forward flexions from a standing position twice in one session with an interval of 30 minutes. The movements were captured by the VICON motion analysis system, and the motion of the sacrum relative to each innominate was estimated in three plans of movement. The test-retest reliability was calculated with the average of three trials using the intraclass correlation coefficient (ICC) with a 95% confidence interval (CI). Results: The measurements demonstrated good to excellent reliability (ICC: from 0.61 to 0.97) that was achieved for the SIJ motion variables. Conclusion: The outcomes of this study showed that the 3D motion analysis can be used for the evaluation of SIJ mobility due to its acceptable reliability.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Three-dimensional shoulder kinematics: Upright four-dimensional computed tomography in comparison with an optical three-dimensional motion capture system
    Yoshida, Yuki
    Matsumura, Noboru
    Miyamoto, Azusa
    Oki, Satoshi
    Yokoyama, Yoichi
    Yamada, Minoru
    Yamada, Yoshitake
    Nakamura, Masaya
    Nagura, Takeo
    Jinzaki, Masahiro
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (01) : 196 - 205
  • [22] Experimental determination of three-dimensional cervical joint mobility in the avian neck
    Kambic, Robert E.
    Biewener, Andrew A.
    Pierce, Stephanie E.
    FRONTIERS IN ZOOLOGY, 2017, 14
  • [23] Reliability of freehand three-dimensional ultrasound to measure scapular rotations
    Worobey, Lynn A.
    Udofa, Ima A.
    Lin, Yen-Sheng
    Koontz, Alicia M.
    Farrokhi, Shawn S.
    Boninger, Michael L.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2014, 51 (06) : 985 - 994
  • [24] Reliability of Kinovea® Software and Agreement with a Three-Dimensional Motion System for Gait Analysis in Healthy Subjects
    Fernandez-Gonzalez, Pilar
    Koutsou, Aikaterini
    Cuesta-Gomez, Alicia
    Carratala-Tejada, Maria
    Carlos Miangolarra-Page, Juan
    Molina-Rueda, Francisco
    SENSORS, 2020, 20 (11)
  • [25] Inter- and intra-examiner reliability of single and composites of selected motion palpation and pain provocation tests for sacroiliac joint
    Arab, Amir Massoud
    Abdollahi, Iraj
    Joghataei, Mohammad Taghi
    Golafshani, Zahra
    Kazemnejad, Anoshirvan
    MANUAL THERAPY, 2009, 14 (02) : 213 - 221
  • [26] Between-day reliability of three-dimensional motion analysis of the trunk: A comparison of marker based protocols
    Rast, Fabian Marcel
    Graf, Eveline Silvia
    Meichtry, Andre
    Kool, Jan
    Bauer, Christoph Michael
    JOURNAL OF BIOMECHANICS, 2016, 49 (05) : 807 - 811
  • [27] Development of a cost effective three-dimensional posture analysis tool: validity and reliability
    Brink, Yolandi
    Louw, Quinette
    Grimmer, Karen
    Schreve, Kristiaan
    van der Westhuizen, Gareth
    Jordaan, Esme
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [28] Reliability of a seated three-dimensional passive intervertebral motion test for mobility, end-feel, and pain provocation in patients with cervicalgia
    Manning, Dana M.
    Dedrick, Gregory S.
    Sizer, Phillip S.
    Brismee, Jean-Michel
    JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2012, 20 (03) : 135 - 141
  • [29] Reliability of a three-dimensional facial camera for dental and medical applications: A pilot study
    Liu, Shiming
    Srinivasan, Murali
    Moerzinger, Roland
    Lancelle, Marcel
    Beeler, Thabo
    Gross, Markus
    Solenthaler, Barbara
    Fehmer, Vincent
    Sailer, Irena
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (03) : 282 - 287
  • [30] Development of a cost effective three-dimensional posture analysis tool: validity and reliability
    Yolandi Brink
    Quinette Louw
    Karen Grimmer
    Kristiaan Schreve
    Gareth van der Westhuizen
    Esmè Jordaan
    BMC Musculoskeletal Disorders, 14