Comparative Study of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments

被引:9
|
作者
Tartea, Daniel Adrian [1 ]
Ionescu, Mihaela [2 ]
Manolea, Horia Octavian [3 ]
Mercut, Veronica [4 ]
Obadan, Eugenia [3 ]
Amarascu, Marina Olimpia [5 ]
Marasescu, Petre Costin [6 ]
Daguci, Luminita
Popescu, Sanda Mihaela [1 ]
机构
[1] Univ Med & Pharm Craiova, Dept Oral Rehabil, Craiova 200349, Romania
[2] Univ Med & Pharm Craiova, Dept Med Informat & Biostat, Craiova 200349, Romania
[3] Univ Med & Pharm Craiova, Dept Dent Mat, Craiova 200349, Romania
[4] Univ Med & Pharm Craiova, Dept Dent Prosthet, Craiova 200349, Romania
[5] Univ Med & Pharm Craiova, Dept Dent Morphol, Craiova 200349, Romania
[6] Univ Med & Pharm Craiova, Dept Dent Technol, Craiova 200349, Romania
关键词
dental prostheses; CAD; CAM; dental technology; evaluation methods; CAD/CAM ABUTMENTS; ANTERIOR REGIONS; STABILITY;
D O I
10.3390/jcm12062128
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The implementation of CAD-CAM systems in dentistry has significantly influenced the evolution of dental implantology and implant-supported prosthetics within the past three decades. Implant-supported prostheses are comfortable and aesthetic. The prosthetic abutment has also faced a rapid design evolution, from the individualization of standard stock abutments offered by various manufacturers to a modern customization process using CAD-CAM technology. This paper presents a comparative study between 20 dental custom CAD-CAM implant abutments and 20 dental implant stock abutments, based on a set of measurements performed on the digital casts obtained from 24 cases of prosthetic rehabilitation on implants. The statistical analysis (Mann-Whitney U test) revealed significant differences between these two types of abutments: the incisal margin line diameter dimensions for custom abutments were significantly improved compared to standard abutments at the cervical level (U = 343.00, z = 3.868, p < 0.0005) and the incisal/occlusal level (U = 352.00, z = 4.112, p < 0.0005), while the inclination angle of the custom abutments relative to the 0-axis was significantly smaller than that of standard abutments (U = 115.50, z = -2.286, p = 0.022). The use of custom abutments leads to an increase in the final size of the abutment, an improvement in the retention of the prosthetic work, and reduces the angulation of the abutment in relation to the implant axis, thus decreasing the risk of unscrewing or fracturing the dental screw.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] A Microscopy Evaluation of Emergence Profile Surfaces of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments
    Tartea, Daniel Adrian
    Manolea, Horia Octavian
    Ionescu, Mihaela
    Gingu, Oana
    Amarascu, Marina Olimpia
    Popescu, Adrian Marcel
    Mercut, Veronica
    Popescu, Sanda Mihaela
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (07):
  • [2] CAD-CAM custom healing abutments: A dental technique
    El-Danasory, Muhammed B.
    Khamis, Mohamed Moataz
    Hakim, Ahmed Adel Abdel
    Fahmy, Rania A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (03): : 496 - 499
  • [3] Assessment of reliability of CAD-CAM tooth-colored implant custom abutments
    Guilherme, Nuno Marques
    Chung, Kwok-Hung
    Flinn, Brian D.
    Zheng, Cheng
    Raigrodski, Ariel J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (02): : 206 - 213
  • [4] An investment technique for custom dental implant abutments
    Takacs, G
    Cameron, SM
    JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (02): : 168 - 168
  • [5] Microleakage assessment of CAD-CAM Cobalt-Chrome and Zirconia abutments on a conical connection dental implant: A comparative in vitro study
    Molinero-Mourelle, Pedro
    Roccuzzo, Andrea
    Yilmaz, Burak
    Lam, Walter Yu Hang
    Pow, Edmond H. N.
    Highsmith, Jaime Del Rio
    Gomez-Polo, Miguel
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (09) : 945 - 952
  • [6] Implant adaptation of stock abutments versus CAD/CAM abutments: a radiographic and Scanning Electron Microscopy study
    Apicella, Davide
    Veltri, Mario
    Chieffi, Nicoletta
    Polimeni, Antonella
    Giovannetti, Agostino
    Ferrari, Marco
    ANNALI DI STOMATOLOGIA, 2010, 1 (3-4) : 9 - 13
  • [7] Influence of Gingival Contour on Marginal Fit of CAD-CAM Zirconia Copings on Implant Stock Abutments
    Markarian, Roberto A.
    Vasconcelos, Ednaria
    Kim, Jun H.
    Cortes, Arthur R. G.
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2021, 29 (01): : P2 - P5
  • [8] COMPARISON OF FRACTURE RESISTANCE OF PRESSABLE METAL CERAMIC CUSTOM IMPLANT ABUTMENTS WITH CAD/CAM COMMERCIALLY FABRICATED ZIRCONIA IMPLANT ABUTMENTS
    Kim, Sungtae
    Kim, Hyeong-Il
    Brewer, Jane D.
    Monaco, Edward A., Jr.
    JOURNAL OF PROSTHETIC DENTISTRY, 2009, 101 (04): : 226 - 230
  • [9] A comparative study of gold UCLA-type and CAD/CAM titanium implant abutments
    Park, Ji-Man
    Lee, Jai-Bong
    Heo, Seong-Joo
    Park, Eun-Jin
    JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (01): : 46 - 52
  • [10] CAD/CAM Technology for Implant Abutments, Crowns, and Superstructures
    Kapos, Theodoros
    Evans, Christopher
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 : 117 - 136