Patient-specific needle guidance templates drilled intraprocedurally for image guided intervention: feasibility study in swine

被引:1
作者
Glossop, Neil [1 ,2 ]
Bale, Reto [3 ]
Xu, Sheng [4 ]
Pritchard, William F. [4 ]
Karanian, John W. [4 ]
Wood, Bradford J. [4 ,5 ,6 ]
机构
[1] Queens Univ, Kingston, ON, Canada
[2] ArciTrax Inc, Toronto, ON, Canada
[3] Med Univ Innsbruck, Innsbruck, Austria
[4] NIH, Ctr Intervent Oncol Radiol & Imaging Sci, Ctr Clin, Bldg 10, Bethesda, MD 20892 USA
[5] Natl Inst Biomed Imaging & Bioengn, Bethesda, MD 20892 USA
[6] NCI, Ctr Canc Res, NIH, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
Point-of-care systems; Ablation; Tomography; X-ray computed; Liver neoplasms; Accuracy evaluation; Imaging; Three-dimensional; RADIOFREQUENCY ABLATION; LIVER; ACCURACY; BIOPSY;
D O I
10.1007/s11548-022-02747-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Thermal ablation of large tumors may benefit from simultaneous placement of multiple needles, but accurate placement becomes challenging as the number of needles increases. The aim of this work was to evaluate use of personalized needle guidance grid templates based on intraprocedural CT and fabricated at the point of care to implement ablation treatment plans with multiple needles in vivo. Methods A plastic frame was designed to hold two parallel plastic guide plates in a rigid relationship, fixed over the abdomen by a mounting arm. Steel ball targets (1.5 mm) were implanted under ultrasound in the livers of two domestic swine under general anesthesia. Following breath-hold CT of the subject and frame, the targets and frame were identified using customized 3D Slicer-based planning software. Multiple needle trajectories targeting the balls were planned, including complex off-plane trajectories. A machining program for drilling the hole pattern corresponding to the planned needle trajectories was generated. The pattern was drilled in the two plates with a numerical-controlled milling machine in the suite. The plates were attached to the frame and needles passed through the paired holes to the calculated depth. Placement accuracy was defined as needle tip-to-target distance on post-placement CT. Results The planning process and manufacturing required approximately 6 and 15 min, respectively. Needles were rapidly inserted (n = 11) to the target points without complications or traversing nontarget anatomy. The mean needle tip-to-target distance error was 3.4 +/- 2.2, range 0-7 mm. Conclusion Rapid and accurate needle placement was feasible using a subject-specific, custom-drilled, needle guidance grid template fabricated intraprocedurally. Targeting accuracy and performance were similar to more complex and expensive tracking systems which may enable accurate intraprocedural implementation of treatment plans in the liver or other organs. This may be of value in complex ablation cases or in areas where more advanced guidance systems are not available.
引用
收藏
页码:537 / 544
页数:8
相关论文
共 14 条
  • [1] Stereotactic Radiofrequency Ablation of Hepatocellular Carcinoma: a Histopathological Study in Explanted Livers
    Bale, Reto
    Schullian, Peter
    Eberle, Gernot
    Putzer, Daniel
    Zoller, Heinz
    Schneeberger, Stefan
    Manzl, Claudia
    Moser, Patrizia
    Oberhuber, Georg
    [J]. HEPATOLOGY, 2019, 70 (03) : 840 - 850
  • [2] Stereotactic Radiofrequency Ablation
    Bale, Reto
    Widmann, Gerlig
    Haidu, Marion
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 (04) : 852 - 856
  • [3] 3D Slicer as an image computing platform for the Quantitative Imaging Network
    Fedorov, Andriy
    Beichel, Reinhard
    Kalpathy-Cramer, Jayashree
    Finet, Julien
    Fillion-Robin, Jean-Christophe
    Pujol, Sonia
    Bauer, Christian
    Jennings, Dominique
    Fennessy, Fiona
    Sonka, Milan
    Buatti, John
    Aylward, Stephen
    Miller, James V.
    Pieper, Steve
    Kikinis, Ron
    [J]. MAGNETIC RESONANCE IMAGING, 2012, 30 (09) : 1323 - 1341
  • [4] SPET/CT image co-registration in the abdomen with a simple and cost-effective tool
    Forster, GJ
    Laumann, C
    Nickel, O
    Kann, P
    Rieker, O
    Bartenstein, P
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (01) : 32 - 39
  • [5] Clinical benefits of new immobilization system for hypofractionated radiotherapy of intrahepatic hepatocellular carcinoma by helical tomotherapy
    Hu, Yong
    Zhou, Yong-Kang
    Chen, Yi-Xing
    Shi, Shi-Ming
    Zeng, Zhao-Chong
    [J]. MEDICAL DOSIMETRY, 2017, 42 (01) : 37 - 41
  • [6] Electromagnetic tracking for thermal ablation and biopsy guidance:: Clinical evaluation of spatial accuracy
    Kruecker, Jochen
    Xu, Sheng
    Glossop, Neil
    Viswanathan, Anand
    Borgert, Joern
    Schulz, Heinrich
    Wood, Bradford J.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (09) : 1141 - 1150
  • [7] TREATMENT PLANNING FOR PERMANENT AND TEMPORARY PERCUTANEOUS IMPLANTS WITH CUSTOM MADE TEMPLATES
    OSIAN, AD
    ANDERSON, LL
    LINARES, LA
    NORI, D
    HILARIS, BS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 16 (01): : 219 - 223
  • [8] Comparison of Two Electromagnetic Navigation Systems For CT-Guided Punctures: A Phantom Study
    Putzer, D.
    Arco, D.
    Schamberger, B.
    Schanda, F.
    Mahlknecht, J.
    Widmann, G.
    Schullian, P.
    Jaschke, W.
    Bale, R.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (05): : 470 - 478
  • [9] Simultaneous Stereotactic Radiofrequency Ablation of Multiple (≥ 4) Liver Tumors: Feasibility, Safety, and Efficacy
    Schullian, Peter
    Putzer, Daniel
    Eberle, Gernot
    Laimer, Gregor
    Bale, Reto
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 31 (06) : 943 - 952
  • [10] Accuracy and diagnostic yield of CT-guided stereotactic liver biopsy of primary and secondary liver tumors
    Schullian, Peter
    Widmann, Gerlig
    Lang, Thomas Bob
    Knoflach, Martin
    Bale, Reto
    [J]. COMPUTER AIDED SURGERY, 2011, 16 (04) : 181 - 187