Acquisition and evaluation procedure to improve the accuracy of SAED

被引:9
|
作者
Czigany, Zsolt [1 ]
Kis, Viktoria Kovacs [1 ]
机构
[1] Ctr Energy Res, Inst Tech Phys & Mat Sci, Konkoly Thege Miklos Ut 29-33, H-1121 Budapest, Hungary
关键词
aberration corrected TEM; bioapatite; evaluation procedure; precision; reproducibility; SAED; AREA ELECTRON-DIFFRACTION; LATTICE-PARAMETERS; NANOCRYSTALLINE ANATASE; PHASE; MICROSTRUCTURE; NANOMATERIALS; DISTORTION; PRECISION; ENAMEL;
D O I
10.1002/jemt.24229
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
The achievement of this work is that fine tuning of experimental and evaluation parameters can improve the absolute accuracy and reproducibility of selected area electron diffraction (SAED) to 0.1% without using internal standard. Due to the proposed procedure it was possible to reach a reproducibility better than 0.03% for camera length between sessions by careful control of specimen height and illumination conditions by monitoring lens currents. We applied a calibration specimen composed of nanocrystalline grains free of texture and providing narrow diffraction rings. Refinements of the centre of the diffraction pattern and corrections for elliptic ring distortions allowed for determining the ring diameters with an accuracy of 0.1%. We analyze the effect of different error sources and reason the achieved absolute accuracy of the measurement. Application of the proposed evaluation procedure is inevitable in case of multicomponent nanocomposites or textured materials and/or having close diffraction rings where application of automate procedures is limited. The achieved accuracy of 0.1% without internal standard is approaching that of routine laboratory XRD, and reduction of instrumental broadening due to the elaborated evaluation procedure allows for separation of close reflections, provides more reliable ring width and thus improved input parameters for further nanostructure analysis as demonstrated on dental enamel bioapatite.
引用
收藏
页码:144 / 156
页数:13
相关论文
共 50 条
  • [31] Advances in coronary computer tomography angiography post-acquisition processing improve the accuracy of detection of stenoses
    Lau, GT
    Ridley, L
    Schieb, M
    Brieger, D
    Kritharides, L
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2003, 30 (5-6) : A11 - A11
  • [32] Development of a Scanner to Improve the Accuracy of Ultrasonic Inspection Signal Acquisition for Welded Parts of Power Plant Facilities
    Jeon, Jun Hee
    Choi, In Hwan
    Park, Sang Ki
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2024, 44 (01) : 15 - 23
  • [33] Measuring procedure of experimental data acquisition and data evaluation of acoustic emission in rock disintegration
    Futo, Jozef
    Krepelka, Frantisek
    Chlebova, Zuzana
    Ivanicova, Lucia
    ACTA MONTANISTICA SLOVACA, 2009, 14 (03) : 254 - 259
  • [34] FORMATION OF PURPOSE FUNCTION AND THE EVALUATION OF EXPERT ACTION IN THE ITERATIVE PROCEDURE OF DATA ACQUISITION AND PROCESSING
    PETROV, VV
    KHATIASHVILI, VG
    DOKLADY AKADEMII NAUK SSSR, 1984, 278 (03): : 568 - 570
  • [35] Development of an ultrasound-imaging procedure and acquisition of ultrasound images of acupuncture points for safety and accuracy of needle insertion
    Kim, Sungha
    Lee, Sanghun
    Ha, Won-Bae
    Lee, Jung-Han
    Jung, Hyun-Jong
    Chu, Hong-Min
    Yang, Seung-Bum
    Choi, Sunmi
    Son, Mi Ju
    Kim, Jae Hyo
    Jeon, Youngju
    INTEGRATIVE MEDICINE RESEARCH, 2017, 6 (04) : 427 - 433
  • [36] A baseline estimation procedure to improve MDA evaluation in gamma-ray spectrometry
    Elio Tomarchio
    Mariarosa Giardina
    Pietro Buffa
    The European Physical Journal Plus, 138
  • [37] A baseline estimation procedure to improve MDA evaluation in gamma-ray spectrometry
    Tomarchio, Elio
    Giardina, Mariarosa
    Buffa, Pietro
    EUROPEAN PHYSICAL JOURNAL PLUS, 2023, 138 (08):
  • [38] GCP ACQUISITION USING SIMULATED SAR AND EVALUATION OF GCP MATCHING ACCURACY WITH TEXTURE FEATURES
    ARAI, K
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 1991, 12 (11) : 2389 - 2397
  • [39] Skeletal landmarks for TKR implantations: Evaluation of their accuracy using EOS imaging acquisition system
    Schlatterer, B.
    Suedhoff, I.
    Bonnet, X.
    Catonne, Y.
    Maestro, M.
    Skalli, W.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2009, 95 (01) : 2 - 11
  • [40] Optimisation procedure for additive manufacturing processes based on mask image projection to improve Z accuracy and resolution
    Bonada, J.
    Muguruza, A.
    Fernandez-Francos, X.
    Ramis, X.
    JOURNAL OF MANUFACTURING PROCESSES, 2018, 31 : 689 - 702