Acquisition and evaluation procedure to improve the accuracy of SAED

被引:9
|
作者
Czigany, Zsolt [1 ]
Kis, Viktoria Kovacs [1 ]
机构
[1] Ctr Energy Res, Inst Tech Phys & Mat Sci, Konkoly Thege Miklos Ut 29-33, H-1121 Budapest, Hungary
关键词
aberration corrected TEM; bioapatite; evaluation procedure; precision; reproducibility; SAED; AREA ELECTRON-DIFFRACTION; LATTICE-PARAMETERS; NANOCRYSTALLINE ANATASE; PHASE; MICROSTRUCTURE; NANOMATERIALS; DISTORTION; PRECISION; ENAMEL;
D O I
10.1002/jemt.24229
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
The achievement of this work is that fine tuning of experimental and evaluation parameters can improve the absolute accuracy and reproducibility of selected area electron diffraction (SAED) to 0.1% without using internal standard. Due to the proposed procedure it was possible to reach a reproducibility better than 0.03% for camera length between sessions by careful control of specimen height and illumination conditions by monitoring lens currents. We applied a calibration specimen composed of nanocrystalline grains free of texture and providing narrow diffraction rings. Refinements of the centre of the diffraction pattern and corrections for elliptic ring distortions allowed for determining the ring diameters with an accuracy of 0.1%. We analyze the effect of different error sources and reason the achieved absolute accuracy of the measurement. Application of the proposed evaluation procedure is inevitable in case of multicomponent nanocomposites or textured materials and/or having close diffraction rings where application of automate procedures is limited. The achieved accuracy of 0.1% without internal standard is approaching that of routine laboratory XRD, and reduction of instrumental broadening due to the elaborated evaluation procedure allows for separation of close reflections, provides more reliable ring width and thus improved input parameters for further nanostructure analysis as demonstrated on dental enamel bioapatite.
引用
收藏
页码:144 / 156
页数:13
相关论文
共 50 条
  • [1] Bagging to improve the accuracy of a clustering procedure
    Dudoit, S
    Fridlyand, J
    BIOINFORMATICS, 2003, 19 (09) : 1090 - 1099
  • [2] Procedure to improve alignment accuracy of collimator reticle
    Wu, Guodong, 1600, Chinese Optical Society (34):
  • [3] PROCEDURE FOR EVALUATION OF PRECISION AND ACCURACY OF ANALYTICAL METHODS
    VIKELSOE, J
    BECHGAARD, E
    MAGID, E
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1974, 34 (02): : 149 - 152
  • [4] ACCURACY TEST PROCEDURE FOR IMAGE EVALUATION TECHNIQUES
    JONES, RA
    APPLIED OPTICS, 1968, 7 (01): : 133 - &
  • [5] SIMPLIFIED BANDSAW TENSIONING PROCEDURE TO IMPROVE BLADE STIFFNESS AND CUTTING ACCURACY
    TAYLOR, J
    HUTTON, SG
    FOREST PRODUCTS JOURNAL, 1995, 45 (04) : 38 - 44
  • [6] Procedure to Improve the Accuracy of Dental Implant Failures by Data Science Techniques
    Ganz, Nancy B.
    Ares, Alicia E.
    Kuna, Horacio D.
    JOURNAL OF COMPUTER SCIENCE & TECHNOLOGY, 2021, 21 (02): : 146 - 156
  • [7] Integrity of Earthing Systems: An Innovative Approach to Improve the Test Procedure Accuracy
    Grange, F.
    Journet, S.
    Dziwniel, P.
    Dawalibi, F. P.
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 2, 2020, 599 : 1173 - 1182
  • [8] Evaluation of methods to improve EUV OPC model accuracy
    Coskun, Tamer H.
    Clifford, Chris
    Fenger, Germain
    Chua, Gek Soon
    Standiford, Keith
    Schlief, Ralph
    Higgins, Craig
    Zou, Yi
    EXTREME ULTRAVIOLET (EUV) LITHOGRAPHY IV, 2013, 8679
  • [9] Using forecast evaluation to improve the accuracy of the Greenbook forecast
    Arai, Natsuki
    INTERNATIONAL JOURNAL OF FORECASTING, 2014, 30 (01) : 12 - 19
  • [10] A procedure of experimental data acquisition for an evaluation of the acoustic emission in the rock disintegration
    Futo, Jozef
    Krepelka, Frantisek
    ACTA MONTANISTICA SLOVACA, 2007, 12 (01) : 20 - 24