Aging of Oil-Impregnated Paper High Voltage Current Transformers: Long Duration Test and Lifespan Estimation

被引:0
|
作者
Spressola, Flavio Eduardo [1 ]
Roman, Zoltan [2 ]
Oliveira, Rodrigo Gomes [1 ]
Lagos, Fernando Moreira [2 ]
Neto, Estacio Tavares Wanderley [3 ]
机构
[1] GE Vernova, BR-37504358 Itajuba, MG, Brazil
[2] GE Vernova, Charleroi, PA 15022 USA
[3] Univ Fed Uberlandia, Uberlandia, MG, Brazil
关键词
Stress; Insulation; Mathematical models; Accelerated aging; Current transformers; Thermal stresses; Power cables; Accelerated aging test; current transformer (CT); life estimation; oil-paper insulation;
D O I
10.1109/TDEI.2023.3321283
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Although the current transformer (CT) is an essential component in the electrical power system and its failure may result in serious consequences, there are no accelerated aging tests for this equipment prescribed by technical standards. Life estimation for this equipment is generally made based on field experience, something that cannot be done for new models and/or new manufacturers. In this work, experimental results of life tests performed on mockups, representing high-voltage CTs with oil-impregnated paper insulation, are presented and discussed. The analysis is based on the application of a multistress model, which combines the Montsinger rule and inverse power law. The proposed approach considers the existence of threshold values for electrical and thermal stresses, below them, electrical and thermal degradation is negligible. An order of magnitude for the electrical stress threshold value ( E-0 ) and for the electrical aging exponent ( n ) is obtained from the application of the test results to the model used in this investigation.
引用
收藏
页码:358 / 365
页数:8
相关论文
共 50 条
  • [1] Aging of oil-impregnated paper in power transformers
    Lundgaard, LE
    Hansen, W
    Linhjell, D
    Painter, TJ
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (01) : 230 - 239
  • [2] ELECTRICAL AGING OF OIL-IMPREGNATED HIGH-VOLTAGE DIELECTRICS
    GANGER, B
    MAIER, G
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1974, EI 9 (03): : 92 - 97
  • [3] The transport of copper through oil-impregnated paper insulation in electrical current transformers and bushings
    Castle, JE
    Whitfield, TB
    Ali, M
    IEEE ELECTRICAL INSULATION MAGAZINE, 2003, 19 (01) : 25 - 29
  • [4] Estimation of the water content in high voltage oil-impregnated transformer insulation
    Shkolnik, A.
    2006 IEEE 24TH CONVENTION OF ELECTRICAL & ELECTRONICS ENGINEERS IN ISRAEL, 2006, : 363 - 367
  • [5] Electrical Aging Lifetime Model of Oil-impregnated Paper under Pulsating DC Voltage Influenced by Temperature
    Li, Jian
    He, Zhiman
    Grzybowski, Stanislaw
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (06) : 1992 - 1997
  • [6] Impact of thermal and electrical aging on Breakdown Strength of Oil-impregnated Paper
    Niasar, Mohamad Ghaffarian
    Taylor, Nathaneil
    Edin, Hans
    Kiiza, Respicius Clemence
    2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [7] Thermal aging behavior of the oil-impregnated paper at 160 degrees C
    Zheng, DC
    Lu, BM
    Yuan, L
    Zheng, DW
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 1997, : 256 - 258
  • [8] Return voltage measurements of oil impregnated paper insulated transformers
    Li, MH
    Dong, M
    Qu, YM
    Zhou, MG
    Yan, Z
    Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 273 - 276
  • [9] Effect of High Voltage Impulses on Partial Discharge Characteristics of Oil-Impregnated Paper for Online Diagnostics
    Nikjoo, Roya
    Taylor, Nathaniel
    Edin, Hans
    2016 IEEE INTERNATIONAL POWER MODULATOR AND HIGH VOLTAGE CONFERENCE (IPMHVC), 2016, : 151 - 156
  • [10] Influence of Thermal Aging on Dielectric Properties of Natural Ester Oil-Impregnated Paper
    Yoon, Hyungjin
    Chen, George
    Hosier, Ian L.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (03) : 1337 - 1344