摘要
Herein, a novel fluorescent probe HZY was developed for monitoring the sulfite (SO32 � ) dynamics. For the first time, the SO32 � triggered implement was applied in the acute liver injury (ALI) model. The levulinate was selected to achieve the specific and relatively steady recognition reaction. With the addition of SO32 , the fluorescence response of HZY exhibited a large Stokes shift of 110 nm under the 380 nm excitation. The merits included high selectivity under various pH conditions. Compared with the reported fluorescent probes for sulfite, HZY indicated above-moderate performances including remarkable and rapid response (40 folds, within 15 min), and high sensitivity (limit of detection = 0.21 & mu;M). Further, HZY could visualize the exogenous and endogenous SO32 � level in living cells. Moreover, HZY could gauge the changing levels of SO32 � in three types (induced by CCl4, APAP, and alcohol) of ALI models. Both in vivo imaging and depth-of-penetration fluorescence imaging demonstrated that HZY could characterize the developmental and therapeutic status during the liver injury process by measuring the dynamic of SO32- . The successful implementation of this project would promote the accurate in-situ detection of SO32 � in liver injury, which was expected to guide the pre-clinical diagnosis and clinical practice.
引用
收藏
页数:8
相关论文
共 56 条
  • [1] Chao JB, 2021, ANAL METHODS-UK, V13, P3535, DOI [10.1039/d1ay00918d, 10.1039/D1AY00918D]
  • [2] A FRET-based probe for detection of the endogenous SO2 in cells
    Chen, Fahong
    Liu, Aikun
    Ji, Ruixue
    Xu, Zhiyang
    Dong, Jian
    Ge, Yanqing
    [J]. DYES AND PIGMENTS, 2019, 165 : 212 - 216
  • [3] Recent Progress in Fluorescent Sensors for Drug-Induced Liver Injury Assessment
    Chen, Jiao
    Huang, Dongyu
    She, Mengyao
    Wang, Zesi
    Chen, Xi
    Liu, Ping
    Zhang, Shengyong
    Li, Jianli
    [J]. ACS SENSORS, 2021, 6 (03) : 628 - 640
  • [4] Precise Synthesis of GSH-Specific Fluorescent Probe for Hepatotoxicity Assessment Guided by Theoretical Calculation
    Chen, Jiao
    Wang, Zesi
    She, Mengyao
    Liu, Mengdi
    Zhao, Zebin
    Chen, Xi
    Liu, Ping
    Zhang, Shengyong
    Li, Jianli
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (36) : 32605 - 32612
  • [5] Design Strategy of Fluorescent Probes for Live Drug-Induced Acute Liver Injury Imaging
    Cheng, Dan
    Xu, Wang
    Gong, Xiangyang
    Yuan, Lin
    Zhang, Xiao-Bing
    [J]. ACCOUNTS OF CHEMICAL RESEARCH, 2021, 54 (02) : 403 - 415
  • [6] High-Selectivity Fluorescent Reporter toward Peroxynitrite in a Coexisting Nonalcoholic Fatty Liver and Drug-Induced Liver Diseases Model
    Cheng, Dan
    Gong, Xiangyang
    Wu, Qian
    Yuan, Jie
    Lv, Yun
    Yuan, Lin
    Zhang, Xiaobing
    [J]. ANALYTICAL CHEMISTRY, 2020, 92 (16) : 11396 - 11404
  • [7] Investigation of Drug-Induced Hepatotoxicity and Its Remediation Pathway with Reaction-Based Fluorescent Probes
    Cheng, Dan
    Xu, Wang
    Yuan, Lin
    Zhang, Xiaobing
    [J]. ANALYTICAL CHEMISTRY, 2017, 89 (14) : 7693 - 7700
  • [8] Cross M, 2005, BLOOD, V106, p130B
  • [9] Visualization of ONOO- and Viscosity in Drug-Induced Hepatotoxicity with Different Fluorescence Signals by a Sensitive Fluorescent Probe
    Deng, Yingzhen
    Feng, Guoqiang
    [J]. ANALYTICAL CHEMISTRY, 2020, 92 (21) : 14667 - 14675
  • [10] A highly selective ratiometric molecular probe for imaging peroxynitrite during drug-induced acute liver injury
    Gong, Xiangyang
    Cheng, Dan
    Li, Wei
    Shen, Yang
    Peng, Rong
    Shi, Ling
    He, Longwei
    Yuan, Lin
    [J]. JOURNAL OF MATERIALS CHEMISTRY B, 2021, 9 (39) : 8246 - 8252