Managing sample introduction problems in hydrophilic interaction liquid chromatography
被引:13
作者:
Taylor, Mark R.
论文数: 0引用数: 0
h-index: 0
机构:
Pfizer Global Res & Dev, Discovery Pk,Ramsgate Rd, Sandwich CT13 9NJ, EnglandPfizer Global Res & Dev, Discovery Pk,Ramsgate Rd, Sandwich CT13 9NJ, England
Taylor, Mark R.
[1
]
Kawakami, Jane
论文数: 0引用数: 0
h-index: 0
机构:
Pfizer Global Res & Dev, 280 Shennecossett Rd, Groton, CT 06340 USAPfizer Global Res & Dev, Discovery Pk,Ramsgate Rd, Sandwich CT13 9NJ, England
Kawakami, Jane
[2
]
McCalley, David V.
论文数: 0引用数: 0
h-index: 0
机构:
Univ West England, Ctr Res Biosci, Frenchay, Bristol BS16 1QY, EnglandPfizer Global Res & Dev, Discovery Pk,Ramsgate Rd, Sandwich CT13 9NJ, England
McCalley, David V.
[3
]
机构:
[1] Pfizer Global Res & Dev, Discovery Pk,Ramsgate Rd, Sandwich CT13 9NJ, England
[2] Pfizer Global Res & Dev, 280 Shennecossett Rd, Groton, CT 06340 USA
[3] Univ West England, Ctr Res Biosci, Frenchay, Bristol BS16 1QY, England
Sample injection can cause serious problems in hydrophilic interaction liquid chromatography (HILIC) when the injection solvent has higher elution strength than the mobile phase (mp). It can lead to asym-metric peak shapes and poor efficiency. The problem can occur when the mp contains a high proportion of organic e.g. 95% acetonitrile (a weak solvent) whereas the injection solvent contains a higher propor-tion of water (a strong solvent) that is necessary to dissolve polar samples. We investigated different strategies to overcome this problem. A simple method is pre-column dilution where the injector is pro-grammed to deliver a plug of weak solvent (e.g. pure acetonitrile) along with the sample dissolved in a solvent with higher water content than the mp. Another option is to use alternative organic solvents to acetonitrile in the injection solvent, e.g. isopropanol, acetone or tetrahydrofuran, that may give enhanced sample solubility. The role of the volume of injection solvents was investigated as well as the possible ef-fects of mass overload on the results. The use of small sample volumes is always recommended to reduce mismatch effects.(c) 2023 Elsevier B.V. All rights reserved.
机构:
Waters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USAWaters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USA
Gritti, Fabrice
;
Alden, Bonnie A.
论文数: 0引用数: 0
h-index: 0
机构:
Waters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USAWaters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USA
Alden, Bonnie A.
;
McLaughlin, Justin
论文数: 0引用数: 0
h-index: 0
机构:
Waters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USAWaters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USA
McLaughlin, Justin
;
Walter, Thomas H.
论文数: 0引用数: 0
h-index: 0
机构:
Waters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USAWaters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USA
机构:
Waters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USAWaters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USA
Gritti, Fabrice
;
Alden, Bonnie A.
论文数: 0引用数: 0
h-index: 0
机构:
Waters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USAWaters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USA
Alden, Bonnie A.
;
McLaughlin, Justin
论文数: 0引用数: 0
h-index: 0
机构:
Waters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USAWaters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USA
McLaughlin, Justin
;
Walter, Thomas H.
论文数: 0引用数: 0
h-index: 0
机构:
Waters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USAWaters Corp, Instrument Core Res Fundamentals & Chem R&D, 34 Maple St, Milford, MA 01757 USA