Behavior of partial-length stiffened and full-length stiffened CFDST columns under axial load

被引:3
作者
Hassan, Aamir [1 ]
Bhat, Javed Ahmad [1 ]
机构
[1] NIT, Dept Civil Engn, Srinagar, India
关键词
CFDST; Stiffened; FEA; ABAQUS; f(c); f(yo); STEEL TUBULAR COLUMNS; STUB COLUMNS; NONLINEAR-ANALYSIS; SHS INNER; CHS OUTER; CONCRETE; STRENGTH; TUBES; PERFORMANCE; DUCTILITY;
D O I
10.1108/WJE-09-2022-0370
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
PurposeConcrete-filled double skin tube (CFDST) columns are considered one of the most effective steel-concrete composite sections owing to the higher load carrying capacity as compared to its counterpart concrete-filled tube (CFT) columns. This paper aims to numerically investigate the performance of axially loaded, circular CFDST short columns, with the innovative strengthening technique of providing stiffeners in outer tubes. Circular steel hollow sections have been adopted for inner as well as outer tubes, while varying the length of rectangular steel stiffeners, fixed inside the outer tubes only, to check the effect of stiffeners in partially and full-length stiffened CFDST columns. Design/methodology/approachThe behaviour of these CFDST columns is investigated numerically by using a verified finite element analysis (FEA) model from the ABAQUS. The behaviour of 20-unstiffened, 80-partially stiffened and 20-full-length stiffened CFDST columns is studied, while varying the strength of steel (f(yo) = 250-750 MPa) and concrete (30-90 MPa). FindingsThe FEA results are verified by comparing them with the previous test results. FEA study has exhibited that, there is a 7%-25% and 39%-49% increase in peak-loads in partially stiffened and full-length stiffened CFDST columns, respectively, compared to unstiffened CFDST columns. Originality/valueEnhanced strength has been observed in partially stiffened and full-length stiffened CFDST columns as compared to unstiffened CFDST columns. Also, a significant effect of strength of concrete has not been observed as compared to the strength of steel.
引用
收藏
页码:455 / 474
页数:20
相关论文
共 62 条
[1]  
ABAQUS, 2014, US MAN AB SOFTW IS P
[2]  
American Concrete Institute, 2023, BUILD COD REQ STRUCT
[3]  
[Anonymous], 2011, 2062 IS, P10
[4]   Analysis and review of concrete-filled double skin steel tubes under compression [J].
Ayough, Pouria ;
Sulong, N. H. Ramli ;
Ibrahim, Zainah .
THIN-WALLED STRUCTURES, 2020, 148
[5]   Statistical prediction of fracture parameters of concrete and implications for choice of testing standard [J].
Bazant, ZP ;
Becq-Giraudon, E .
CEMENT AND CONCRETE RESEARCH, 2002, 32 (04) :529-556
[6]  
BERGMANN R, 1994, TUBULAR STRUCTURES VI, P373
[7]   Experimental and numerical analysis of circular concrete-filled double steel tubular stub columns with inner square hollow section [J].
Ci, Junchang ;
Jia, Hong ;
Ahmed, Mizan ;
Chen, Shicai ;
Zhou, Daxing ;
Hou, Liqun .
ENGINEERING STRUCTURES, 2021, 227
[8]   Finite element simulation of circular short CFDST columns under axial compression [J].
Elchalakani, M. ;
Patel, V., I ;
Karrech, A. ;
Hassanein, M. F. ;
Fawzia, S. ;
Yang, B. .
STRUCTURES, 2019, 20 :607-619
[9]   Tests on concrete filled double-skin (CHS outer and SHS inner) composite short columns under axial compression [J].
Elchalakani, M ;
Zhao, XL ;
Grzebieta, R .
THIN-WALLED STRUCTURES, 2002, 40 (05) :415-441
[10]   Experimental investigation of rubberised concrete-filled double skin square tubular columns under axial compression [J].
Elchalakani, Mohamed ;
Hassanein, M. F. ;
Karrech, Ali ;
Yang, Bo .
ENGINEERING STRUCTURES, 2018, 171 :730-746