Effect of typical low-impact development measures on control of thermal loads from urban stormwater runoff

被引:3
作者
Li, Jing [1 ]
Li, Junqi [1 ,2 ]
Li, Zimu [1 ]
Li, Xiaojing [1 ]
Si, Shuai [1 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Key Lab Urban Stormwater Syst & Water Environm, Minist Educ, Beijing 100044, Peoples R China
[2] Beijing Energy Conservat & Sustainable Urban & Rur, Beijing 100044, Peoples R China
基金
中国国家自然科学基金;
关键词
Stormwater runoff; Thermal load; Bioretention; Peak control; LID renovation; IMPERVIOUS SURFACES; CLIMATE-CHANGE; TEMPERATURE; POLLUTION; MITIGATION; HEAT;
D O I
10.1016/j.scitotenv.2023.166915
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ground hardening in urban areas increases the risk of thermal enrichment in surface rainwater runoff. Moreover, the thermal pollution from rainwater runoff has become an important problem that damages the urban aquatic environment. Current studies have focused mainly on the potential hazard caused by runoff thermal pollution to aquatic microorganisms. However, there are few studies on the efficacy of controlling runoff thermal load through low-impact development (LID) and renovation in urban areas. The effects of LID modification were evaluated by monitoring the characteristics of the runoff thermal load on each underlying surface in the study area and conducting laboratory-scale bioretention experiments. The results showed that the initial thermal effect of each underlying surface was significant after the start of rainfall, based on the thermal load. Ceramic granules are remarkable bioretention fillers. Their average heat load and volume reduction rates are 55.6 % and 32.7 %, respectively. After LID modification, the thermal load of surface runoff in the study area decreased to 73.42 % under similar rainfall conditions. After the secondary treatment of the bioretention facility, the total thermal load of the outflow facility was 31.40 % of that before renovation. The peak thermal load reduced by 69.15 % and was delayed for 10 min. The control effect differed statistically.
引用
收藏
页数:11
相关论文
共 40 条
[1]  
Barbis J., 2010, Proceedings of the World Environmental and Water Resources Congress 2010, Providence, Rhode Island, USA, 16-20 May, 2010, P3971
[2]   Subsurface Temperature Properties for Three Types of Permeable Pavements in Cold Weather Climates and Implications for Deicer Reduction [J].
Danz, Mari E. ;
Buer, Nicolas H. ;
Selbig, William R. .
WATER, 2021, 13 (24)
[3]   Habitat pollution and thermal regime modify molecular stress responses to elevated temperature in freshwater mussels (Anodonta anatina: Unionidae) [J].
Falfushynska, H. ;
Gnatyshyna, L. ;
Yurchak, I. ;
Ivanina, A. ;
Stoliar, O. ;
Sokolova, I. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 500 :339-350
[4]  
Flower W., 2010, Low Impact Development 2010: Redefining Water in the City, P1417
[5]  
Galli John., 1990, THERMAL IMPACTS ASS
[6]   Temperature dynamics of stormwater runoff in Australia and the USA [J].
Hathaway, J. M. ;
Winston, R. J. ;
Brown, R. A. ;
Hunt, W. F. ;
McCarthy, D. T. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 559 :141-150
[7]   Thermal pollution of streams by runoff from paved surfaces [J].
Herb, William R. ;
Janke, Ben ;
Mohseni, Omid ;
Stefan, Heinz G. .
HYDROLOGICAL PROCESSES, 2008, 22 (07) :987-999
[8]   Modeling the reduction of urban excess heat by green roofs with respect to different irrigation scenarios [J].
Heusinger, Jannik ;
Sailor, David J. ;
Weber, Stephan .
BUILDING AND ENVIRONMENT, 2018, 131 :174-183
[9]  
Hu Y.L., 2012, Analytical of Study on the Overall Benefits of LID Storm Water System.
[10]   Meeting Hydrologic and Water Quality Goals through Targeted Bioretention Design [J].
Hunt, William F. ;
Davis, Allen P. ;
Traver, Robert G. .
JOURNAL OF ENVIRONMENTAL ENGINEERING, 2012, 138 (06) :698-707