Active osseointegration in an ex vivo porcine bone model

被引:1
|
作者
Hall, Thomas A. G. [1 ]
Theodoridis, Konstantinos [1 ]
Kohli, Nupur [1 ]
Cegla, Frederic [2 ]
van Arkel, Richard J. [1 ]
机构
[1] Imperial Coll London, Dept Mech Engn, Biomech Grp, London, England
[2] Imperial Coll London, Dept Mech Engn, Nondestruct Evaluat Grp, London, England
基金
英国工程与自然科学研究理事会;
关键词
osseointegration; osteogenesis; bioelectronics; mechanobiology; bioreactor; INTENSITY PULSED ULTRASOUND; IMPLANT OSSEOINTEGRATION; CELL-ADHESION; STEM-CELLS; IN-VITRO; TITANIUM; DIFFERENTIATION; STIMULATION;
D O I
10.3389/fbioe.2024.1360669
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Achieving osseointegration is a fundamental requirement for many orthopaedic, oral, and craniofacial implants. Osseointegration typically takes three to 6 months, during which time implants are at risk of loosening. The aim of this study was to investigate whether osseointegration could be actively enhanced by delivering controllable electromechanical stimuli to the periprosthetic bone. First, the osteoconductivity of the implant surface was confirmed using an in vitro culture with murine preosteoblasts. The effects of active treatment on osseointegration were then investigated in a 21-day ex vivo model with freshly harvested cancellous bone cylinders (n = 24; & Oslash;10 mm x 5 mm) from distal porcine femora, with comparisons to specimens treated by a distant ultrasound source and static controls. Cell viability, proliferation and distribution was evident throughout culture. Superior ongrowth of tissue onto the titanium discs during culture was observed in the actively stimulated specimens, with evidence of ten-times increased mineralisation after 7 and 14 days of culture (p < 0.05) and 2.5 times increased expression of osteopontin (p < 0.005), an adhesive protein, at 21 days. Moreover, histological analyses revealed increased bone remodelling at the implant-bone interface in the actively stimulated specimens compared to the passive controls. Active osseointegration is an exciting new approach for accelerating bone growth into and around implants.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Osseointegration improves bone-implant interface of pedicle screws in the growing spine: a biomechanical and histological study using an in vivo immature porcine model
    Shiba, Kanako
    Taneichi, Hiroshi
    Namikawa, Takashi
    Inami, Satoshi
    Takeuchi, Daisaku
    Nohara, Yutaka
    EUROPEAN SPINE JOURNAL, 2017, 26 (11) : 2754 - 2762
  • [42] Bone-in-culture Array to Model Bone Metastasis in ex vivo Condition
    Wang, Hai
    Zhang, Xiang H-F
    BIO-PROTOCOL, 2020, 10 (02):
  • [43] A Novel Ex vivo Culture Model for Inflammatory Bone Destruction
    Sloan, A. J.
    Taylor, S. Y.
    Smith, E. L.
    Roberts, J. L.
    Chen, L.
    Wei, X. Q.
    Waddington, R. J.
    JOURNAL OF DENTAL RESEARCH, 2013, 92 (08) : 728 - 734
  • [44] An Ex Vivo Rodent Mandible Culture Model for Bone Repair
    Smith, Emma L.
    Locke, Matthew
    Waddington, Rachel J.
    Sloan, Alastair J.
    TISSUE ENGINEERING PART C-METHODS, 2010, 16 (06) : 1287 - 1296
  • [45] Ex Vivo Analysis of a Porcine Bicuspid Aortic Valve and Aneurysm Disease Model
    Zhu, Yuanjia
    Imbrie-Moore, Annabel M.
    Park, Matthew H.
    Paulsen, Michael J.
    Wang, Hanjay
    MacArthur, John W.
    Woo, Y. Joseph
    ANNALS OF THORACIC SURGERY, 2021, 111 (02): : E113 - E115
  • [46] Evaluation of an ex vivo porcine model to investigate the effect of low abrasive airpolishing
    Gregor Petersilka
    Ralph Heckel
    Raphael Koch
    Benjamin Ehmke
    Nicole Arweiler
    Clinical Oral Investigations, 2018, 22 : 2669 - 2673
  • [47] An Ex-Vivo Model for Hypothermic Pulsatile Perfusion of Porcine Pancreata.
    Karcz, Marcin
    Dorling, Anthony
    Cook, H. Terence
    Papalois, Vassilios
    AMERICAN JOURNAL OF TRANSPLANTATION, 2009, 9 : 267 - 268
  • [48] Fluid-structure-acoustic interactions in an ex vivo porcine phonation model
    Semmler, Marion
    Berry, David A.
    Schuetzenberger, Anne
    Doellinger, Michael
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2021, 149 (03): : 1657 - 1673
  • [49] ALBUTEROL DELIVERY DURING MECHANICAL VENTILATION IN AN EX-VIVO PORCINE MODEL
    Berlinski, A.
    Holt, S.
    Thurman, T.
    Heulitt, M.
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2013, 26 (02) : A57 - A57
  • [50] Elastic properties of the young aorta: ex vivo perfusion experiments in a porcine model
    Krueger, Tobias
    Grigoraviciute, Akvile
    Veseli, Kujtim
    Schibilsky, David
    Wendel, Hans P.
    Schneider, Wilke
    Schlensak, Christian
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 48 (02) : 221 - 227