Evaluating false-positive detection in a computer-aided detection system for colonoscopy

被引:3
作者
Okumura, Taishi [1 ]
Imai, Kenichiro [1 ,3 ]
Misawa, Masashi [2 ]
Kudo, Shin-ei [2 ]
Hotta, Kinichi [1 ]
Ito, Sayo [1 ]
Kishida, Yoshihiro [1 ]
Takada, Kazunori [1 ]
Kawata, Noboru [1 ]
Maeda, Yuki [1 ]
Yoshida, Masao [1 ]
Yamamoto, Yoichi [1 ]
Minamide, Tatsunori [1 ]
Ishiwatari, Hirotoshi [1 ]
Sato, Junya [1 ]
Matsubayashi, Hiroyuki [1 ]
Ono, Hiroyuki [1 ]
机构
[1] Shizuoka Canc Ctr, Div Endoscopy, Shizuoka, Japan
[2] Showa Univ, Northern Yokohama Hosp, Digest Dis Ctr, Yokohama, Japan
[3] Shizuoka Canc Ctr, Div Endoscopy, 1007 Shimonagakubo, Nagaizumi, Shizuoka 4118777, Japan
关键词
Adenoma; Artificial intelligence; Colonoscopy; Colorectal cancer; Computer-aided detection; DIFFERENTIAL-DIAGNOSIS; POLYP DETECTION; NEOPLASIA; TRIAL; RISK;
D O I
10.1111/jgh.16491
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aim: Computer-aided detection (CADe) systems can efficiently detect polyps during colonoscopy. However, false-positive (FP) activation is a major limitation of CADe. We aimed to compare the rate and causes of FP using CADe before and after an update designed to reduce FP. Methods: We analyzed CADe-assisted colonoscopy videos recorded between July 2022 and October 2022. The number and causes of FPs and excessive time spent by the endoscopist on FP (ET) were compared pre- and post-update using 1:1 propensity score matching. Results: During the study period, 191 colonoscopy videos (94 and 97 in the pre- and post-update groups, respectively) were recorded. Propensity score matching resulted in 146 videos (73 in each group). The mean number of FPs and median ET per colonoscopy were significantly lower in the post-update group than those in the pre-update group (4.2 +/- 3.7 vs 18.1 +/- 11.1; P < 0.001 and 0 vs 16 s; P < 0.001, respectively). Mucosal tags, bubbles, and folds had the strongest association with decreased FP post-update (pre-update vs post-update: 4.3 +/- 3.6 vs 0.4 +/- 0.8, 0.32 +/- 0.70 vs 0.04 +/- 0.20, and 8.6 +/- 6.7 vs 1.6 +/- 1.7, respectively). There was no significant decrease in the true positive rate (post-update vs pre-update: 95.0% vs 99.2%; P = 0.09) or the adenoma detection rate (post-update vs pre-update: 52.1% vs 49.3%; P = 0.87). Conclusions: The updated CADe can reduce FP without impairing polyp detection. A reduction in FP may help relieve the burden on endoscopists.
引用
收藏
页码:927 / 934
页数:8
相关论文
共 40 条
[21]   Postcolonoscopy colorectal cancers are preventable: a population-based study [J].
le Clercq, Chantal M. C. ;
Bouwens, Marielle W. E. ;
Rondagh, Eveline J. A. ;
Bakker, C. Minke ;
Keulen, Eric T. P. ;
de Ridder, Rogier J. ;
Winkens, Bjorn ;
Masclee, Ad A. M. ;
Sanduleanu, Silvia .
GUT, 2014, 63 (06) :957-963
[22]   Expected value of artificial intelligence in gastrointestinal endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Position Statement [J].
Messmann, Helmut ;
Bisschops, Raf ;
Antonelli, Giulio ;
Libanio, Diogo ;
Sinonquel, Pieter ;
Abdelrahim, Mohamed ;
Ahmad, Omer F. ;
Areia, Miguel ;
Bergman, Jacques J. G. H. M. ;
Bhandari, Pradeep ;
Boskoski, Ivo ;
Dekker, Evelien ;
Domagk, Dirk ;
Ebigbo, Alanna ;
Eelbode, Tom ;
Eliakim, Rami ;
Haefner, Michael ;
Haidry, Rehan J. ;
Jover, Rodrigo ;
Kaminski, Michal F. ;
Kuvaev, Roman ;
Mori, Yuichi ;
Palazzo, Maxime ;
Repici, Alessandro ;
Rondonotti, Emanuele ;
Rutter, Matthew D. ;
Saito, Yutaka ;
Sharma, Prateek ;
Spada, Cristiano ;
Spadaccini, Marco ;
Veitch, Andrew ;
Gralnek, Ian M. ;
Hassan, Cesare ;
Dinis-Ribeiro, Mario .
ENDOSCOPY, 2022, 54 (12) :1211-1231
[23]   Current status and future perspective on artificial intelligence for lower endoscopy [J].
Misawa, Masashi ;
Kudo, Shin-ei ;
Mori, Yuichi ;
Maeda, Yasuharu ;
Ogawa, Yushi ;
Ichimasa, Katsuro ;
Kudo, Toyoki ;
Wakamura, Kunihiko ;
Hayashi, Takemasa ;
Miyachi, Hideyuki ;
Baba, Toshiyuki ;
Ishida, Fumio ;
Itoh, Hayato ;
Oda, Masahiro ;
Mori, Kensaku .
DIGESTIVE ENDOSCOPY, 2021, 33 (02) :273-284
[24]   Development of a computer-aided detection system for colonoscopy and a publicly accessible large colonoscopy video database (with video) [J].
Misawa, Masashi ;
Kudo, Shin-ei ;
Mori, Yuichi ;
Hotta, Kinichi ;
Ohtsuka, Kazuo ;
Matsuda, Takahisa ;
Saito, Shoichi ;
Kudo, Toyoki ;
Baba, Toshiyuki ;
Ishida, Fumio ;
Itoh, Hayato ;
Oda, Masahiro ;
Mori, Kensaku .
GASTROINTESTINAL ENDOSCOPY, 2021, 93 (04) :960-+
[25]   Artificial Intelligence-Assisted Polyp Detection for Colonoscopy: Initial Experience [J].
Misawa, Masashi ;
Kudo, Shin-ei ;
Mori, Yuichi ;
Cho, Tomonari ;
Kataoka, Shinichi ;
Yamauchi, Akihiro ;
Ogawa, Yushi ;
Maeda, Yasuharu ;
Takeda, Kenichi ;
Ichimasa, Katsuro ;
Nakamura, Hiroki ;
Yagawa, Yusuke ;
Toyoshima, Naoya ;
Ogata, Noriyuki ;
Kudo, Toyoki ;
Hisayuki, Tomokazu ;
Hayashi, Takemasa ;
Wakamura, Kunihiko ;
Baba, Toshiyuki ;
Ishida, Fumio ;
Itoh, Hayato ;
Roth, Holger ;
Oda, Masahiro ;
Mori, Kensaku .
GASTROENTEROLOGY, 2018, 154 (08) :2027-+
[26]   The 2019 WHO classification of tumours of the digestive system [J].
Nagtegaal, Iris D. ;
Odze, Robert D. ;
Klimstra, David ;
Paradis, Valerie ;
Rugge, Massimo ;
Schirmacher, Peter ;
Washington, Kay M. ;
Carneiro, Fatima ;
Cree, Ian A. .
HISTOPATHOLOGY, 2020, 76 (02) :182-188
[27]   Framework and metrics for the clinical use and implementation of artificial intelligence algorithms into endoscopy practice: recommendations from the American Society for Gastrointestinal Endoscopy Artificial Intelligence Task Force [J].
Parasa, Sravanthi ;
Repici, Alessandro ;
Berzin, Tyler ;
Leggett, Cadman ;
Gross, Seth A. ;
Sharma, Prateek .
GASTROINTESTINAL ENDOSCOPY, 2023, 97 (05) :815-+
[28]   Updates on Age to Start and Stop Colorectal Cancer Screening: Recommendations From the US Multi-Society Task Force on Colorectal Cancer [J].
Patel, Swati G. ;
May, Folasade P. ;
Anderson, Joseph C. ;
Burke, Carol A. ;
Dominitz, Jason A. ;
Gross, Seth A. ;
Jacobson, Brian C. ;
Shaukat, Aasma ;
Robertson, Douglas J. .
GASTROENTEROLOGY, 2022, 162 (01) :285-299
[29]   Artificial intelligence and colonoscopy experience: lessons from two randomised trials [J].
Repici, Alessandro ;
Spadaccini, Marco ;
Antonelli, Giulio ;
Correale, Loredana ;
Maselli, Roberta ;
Galtieri, Piera Alessia ;
Pellegatta, Gaia ;
Capogreco, Antonio ;
Milluzzo, Sebastian Manuel ;
Lollo, Gianluca ;
Di Paolo, Dhanai ;
Badalamenti, Matteo ;
Ferrara, Elisa ;
Fugazza, Alessandro ;
Carrara, Silvia ;
Anderloni, Andrea ;
Rondonotti, Emanuele ;
Amato, Arnaldo ;
De Gottardi, Andrea ;
Spada, Cristiano ;
Radaelli, Franco ;
Savevski, Victor ;
Wallace, Michael B. ;
Sharma, Prateek ;
Roesch, Thomas ;
Hassan, Cesare .
GUT, 2022, 71 (04) :757-765
[30]   Efficacy of Real-Time Computer-Aided Detection of Colorectal Neoplasia in a Randomized Trial [J].
Repici, Alessandro ;
Badalamenti, Matteo ;
Maselli, Roberta ;
Correale, Loredana ;
Radaelli, Franco ;
Rondonotti, Emanuele ;
Ferrara, Elisa ;
Spadaccini, Marco ;
Alkandari, Asma ;
Fugazza, Alessandro ;
Anderloni, Andrea ;
Galtieri, Piera Alessia ;
Pellegatta, Gaia ;
Carrara, Silvia ;
Di Leo, Milena ;
Craviotto, Vincenzo ;
Lamonaca, Laura ;
Lorenzetti, Roberto ;
Andrealli, Alida ;
Antonelli, Giulio ;
Wallace, Michael ;
Sharma, Prateek ;
Rosch, Thomas ;
Hassan, Cesare .
GASTROENTEROLOGY, 2020, 159 (02) :512-+