Cyclic Response of Sloped Extended End-Plate Moment Connections

被引:1
|
作者
Sun, Guohua [1 ]
Li, Zhiqin [1 ]
Fang, Youzhen [1 ]
Lin, Jun [2 ]
Gong, Futao [1 ]
机构
[1] Suzhou Univ Sci andTechnol, Sch Civil Engn, Suzhou 215011, Jiangsu, Peoples R China
[2] Jinggong Steel Bldg Grp, Shaoxing 312030, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Sloped connection; End-plate; Hysteretic behavior; Cyclic loading; Finite element;
D O I
10.1061/JSENDH.STENG-11810
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Bolted extended end-plate (BEEP) moment connections are extensively recommended in design standards to be used as a prequalified beam-to-column connection in steel portal frames and special moment frame buildings. These standards assume that in such a connection, the beam is perpendicular to the steel column or that the slope angle of the steel beam is very small. To expand the engineering applications of BEEP connections in large-slope angle buildings, in this study, three one-sided specimens at half scale with 0 degrees, 15 degrees, and 30 degrees slope angles, respectively, were designed and tested under cyclic loading. All dimensions of these specimens were identical, except the slope angles of their steel beams. The experimental results showed that the maximum rotation angles of these sloped BEEP connections exceeded 0.05 rad, and they were remarkably larger than those of other types of sloped rigid-moment connections tested by Mashayekh and Uang. However, the force concentration that occurred in the flange at the heel location was similar to that observed by them, and it led to the development of brittle fractures. Particularly, with the increase in the slope angle, the force concentration tended to become more severe. Three strengthening schemes for reducing the force concentration and enhancing the deformation capacities of the sloped BEEP connections subjected to the extremely rare earthquake, i.e., less than 2% probability of exceedance in 50 years, were evaluated using the finite element approach. These were Scheme I: stiffening the rib in the acute-angle zone, Scheme II: employing a reduced beam section (RBS) connection, and Scheme III: forming a curved web cut in a non-RBS beam. The analytical results showed that the three schemes decreased the von Mises stress level in the acute-angle zone of the connection web. Scheme I enhanced the initial rotation stiffness, flexural strength, and deformation rotation capacity. For Scheme II, a RBS configuration was employed, which effectively improved the connection rotation capacity, whereas it decreased the flexural strength of the sloped BEEP connection. Scheme III without a reasonable design led to a degradation of the hysteretic performance, moderate rotation capacity, and low flexural strength. Therefore, Schemes I and II leading to much better seismic behavior than Scheme III are recommended.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Influences of Semi-rigidity of End-plate Joints on Structures
    Wang, Qiongfen
    Liu, Yuancai
    Cao, Liang
    Yao, Ji
    Huang, Jianfeng
    MATERIALS PROCESSING TECHNOLOGY, PTS 1-4, 2011, 291-294 : 1625 - +
  • [32] Characterization of web panel components in double-extended bolted end-plate steel joints
    Augusto, Hugo
    da Silva, Luis Simoes
    Rebelo, Carlos
    Castro, Jose Miguel
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 116 : 271 - 293
  • [33] Test on seismic behaviors of stainless steel bolted extended end-plate beam-column joints
    Zheng, Baofeng
    Wu, Dianhan
    Wang, Jiachang
    Shu, Ganping
    THIN-WALLED STRUCTURES, 2024, 196
  • [34] Seismic performance of prefabricated composite frame beam-column joints with grouted end-plate bolted connections
    Zhang X.
    Ma X.
    Zhang S.
    Li Q.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 : 101 - 111
  • [35] NONLINEAR FINITE ELEMENT ANALYSIS OF BEAM-TO-COLUMN END-PLATE CONNECTIONS WITH WEB OPENING IN STEEL STRUCTURES
    Fan, Bao-Feng
    Yang, Qing-Shan
    Yang, Na
    PROCEEDINGS OF THE TENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS I AND II, 2008, : 218 - 223
  • [36] Numerical Study on High Strength Q690 Steel Flush End-Plate Connections at Elevated Temperatures
    Wang, Weiyong
    Li, Siqi
    Ran, Tian
    FIRE TECHNOLOGY, 2024, 60 (05) : 3269 - 3294
  • [37] Experimental behaviour of extended end-plate composite beam-to-column joints subjected to reversal of loading
    Hu, Xiamin
    Zheng, Desheng
    Yang, Li
    STRUCTURAL ENGINEERING AND MECHANICS, 2006, 24 (03) : 307 - 321
  • [38] Shear behavior of the panel zones in end-plate connection
    Wang, Kehan
    Li, Zhenyu
    Rong, Bin
    Zhang, Ruoyu
    Sun, Yiliang
    Zhang, Wuchen
    Wu, Hailiang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 229
  • [39] A new idea to improve the cyclic performance of end plate beam-column connections
    Shaheen, Mohamed A.
    ENGINEERING STRUCTURES, 2022, 253
  • [40] The vertebral end-plate: what do we know?
    Moore, RJ
    EUROPEAN SPINE JOURNAL, 2000, 9 (02) : 92 - 96