Cyclic Response of Sloped Extended End-Plate Moment Connections

被引:1
|
作者
Sun, Guohua [1 ]
Li, Zhiqin [1 ]
Fang, Youzhen [1 ]
Lin, Jun [2 ]
Gong, Futao [1 ]
机构
[1] Suzhou Univ Sci andTechnol, Sch Civil Engn, Suzhou 215011, Jiangsu, Peoples R China
[2] Jinggong Steel Bldg Grp, Shaoxing 312030, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Sloped connection; End-plate; Hysteretic behavior; Cyclic loading; Finite element;
D O I
10.1061/JSENDH.STENG-11810
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Bolted extended end-plate (BEEP) moment connections are extensively recommended in design standards to be used as a prequalified beam-to-column connection in steel portal frames and special moment frame buildings. These standards assume that in such a connection, the beam is perpendicular to the steel column or that the slope angle of the steel beam is very small. To expand the engineering applications of BEEP connections in large-slope angle buildings, in this study, three one-sided specimens at half scale with 0 degrees, 15 degrees, and 30 degrees slope angles, respectively, were designed and tested under cyclic loading. All dimensions of these specimens were identical, except the slope angles of their steel beams. The experimental results showed that the maximum rotation angles of these sloped BEEP connections exceeded 0.05 rad, and they were remarkably larger than those of other types of sloped rigid-moment connections tested by Mashayekh and Uang. However, the force concentration that occurred in the flange at the heel location was similar to that observed by them, and it led to the development of brittle fractures. Particularly, with the increase in the slope angle, the force concentration tended to become more severe. Three strengthening schemes for reducing the force concentration and enhancing the deformation capacities of the sloped BEEP connections subjected to the extremely rare earthquake, i.e., less than 2% probability of exceedance in 50 years, were evaluated using the finite element approach. These were Scheme I: stiffening the rib in the acute-angle zone, Scheme II: employing a reduced beam section (RBS) connection, and Scheme III: forming a curved web cut in a non-RBS beam. The analytical results showed that the three schemes decreased the von Mises stress level in the acute-angle zone of the connection web. Scheme I enhanced the initial rotation stiffness, flexural strength, and deformation rotation capacity. For Scheme II, a RBS configuration was employed, which effectively improved the connection rotation capacity, whereas it decreased the flexural strength of the sloped BEEP connection. Scheme III without a reasonable design led to a degradation of the hysteretic performance, moderate rotation capacity, and low flexural strength. Therefore, Schemes I and II leading to much better seismic behavior than Scheme III are recommended.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Experimental investigation of bolted stiffened end-plate and bolted flange-plate connections
    Yilmaz, Orkun
    Bekiroglu, Serkan
    Alemdar, Fatih
    Arslan, Guray
    Sevim, Barn
    Ayvaz, Yusuf
    LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2019, 16 (03):
  • [22] Numerical Investigation of Fillet Welds in HSS-to-Rigid End-Plate Connections
    Tousignant, Kyle
    Packer, Jeffrey A.
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (12)
  • [23] Cyclic behaviour of end-plate beam-to-column composite joints
    Simoes, Rui
    da Silva, Luis Simoes
    Cruz, Paulo
    STEEL AND COMPOSITE STRUCTURES, 2001, 1 (03): : 355 - 376
  • [24] Hysteretic performance of stainless steel double extended end-plate beam-to-column joints subject to cyclic loading
    Gao, J. D.
    Du, X. X.
    Yuan, H. X.
    Theofanous, M.
    THIN-WALLED STRUCTURES, 2021, 164
  • [25] Study on the prying force of high strength bolt in extended end-plate connection
    Mao, Hui
    Wang, Yan
    Zheng, Jie
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL, SPACE & COMPOSITE STRUCTURES, 2007, : 395 - +
  • [26] Cyclic behaviour characterization of web panel components in bolted end-plate steel joints
    Augusto, Hugo
    da Silva, Luis Simoes
    Rebelo, Carlos
    Castro, Jose Miguel
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 133 : 310 - 333
  • [27] DISCOGRAPHY CAUSES END-PLATE DEFLECTION
    HEGGENESS, MH
    DOHERTY, BJ
    SPINE, 1993, 18 (08) : 1050 - 1053
  • [28] Structural Behavior of Column-to-Beam Connections for End-plate Yielding Using SN Steel
    Kim, Sun Hee
    Jung, Hun Mo
    Choi, Sung Mo
    Chae, Heong Seok
    Lee, Seong Hui
    STEEL CONCRETE COMPOSITE AND HYBRID STRUCTURES, 2009, : 633 - 640
  • [29] Characterization of the cyclic behavior of the web components in end-plate beam-to-column joints
    Augusto, Hugo
    Castro, Jose Miguel
    Rebelo, Carlos
    da Silva, Luis Simoes
    XVIII INTERNATIONAL COLLOQUIUM ON MECHANICAL FATIGUE OF METALS (ICMFM XVIII), 2016, 160 : 101 - 108
  • [30] Numerical study on the behaviour of end-plate beam-to-column connections under lateral impact loading
    Al-Rifaie, Ali
    Al-Husainy, Alaa S.
    Shanbara, Hayder K.
    INTERNATIONAL JOURNAL OF STRUCTURAL ENGINEERING, 2020, 10 (02) : 150 - 173