Intra- and interobserver reliability of two classification systems for posterolateral tibial plateau fractures in the setting of an ACL rupture

被引:0
|
作者
Moreels, Robin [1 ,2 ,5 ]
Vervaecke, Alexander J. [1 ,3 ,4 ]
Van Haver, Annemieke [3 ]
Heylen, Steven [1 ,4 ]
机构
[1] Heilig Hart Ziekenhuis Lier, Dept Trauma & Orthopaed, B-2500 Lier, Belgium
[2] Univ Ghent, Dept Orthopaed Surg & Traumatol, 10 Corneel Heymanslaan, B-9000 Ghent, Belgium
[3] AZ Monica, Orthopaed Ctr Antwerp, B-2018 Antwerp, Belgium
[4] Univ Antwerp, Dept Orthopaed Surg, B-2650 Edegem, Belgium
[5] Corneel Heymanslaan 10, B-9000 Ghent, Belgium
关键词
Posterolateral impaction fracture; ACL tear; Anterior cruciate ligament; Classification; INJURY;
D O I
10.1016/j.jor.2024.01.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Posterolateral tibial plateau impaction fractures occur frequently associated with anterior cruciate ligament (ACL) tears. Some authors advocate operative treatment of high-grade impaction fractures, which has led to the development of classification systems. Our study aims (1) to describe and compare the intra- and interobserver reliability of the two most used classifications and (2) to assess correlations between the grade of bony posterolateral tibial injury, patient characteristics and short -to mid-term revision rate after ACL reconstruction. Materials and methods: In a retrospective series of 163 patients who underwent ACL reconstruction, two reviewers independently evaluated the preoperative MRI scans. Conform the Menzdorf and Bernholt classification the presence and grade of an associated posterolateral impaction fracture were assessed. Statistical analyses were performed to test for both study hypotheses. Results: 171 primary ACL cases were evaluated. Mean follow-up time was 41 months (range 12-154, SD = 17.1). Mean age was 32 years (range 13-59, SD = 12). Posterolateral impaction fractures were present in 111 (64.9 %) and 120 (70.0 %) cases, according to the Menzdorf and Bernholt classification. A Segond fracture was present in 19 (11.1 %) cases. Kappa value was 0.47 for intra- and 0.52 for the interobserver reliability for the Menzdorf classification (moderate reliability). For the Bernholt classification kappa values were 0.66 and 0.61, respectively (good reliability). A Segond fracture correlated significantly with the presence of a posterolateral impaction fracture (p < 0.05). A significant association was present between patients necessitating ACL revision surgery and patients for whom operative intervention for the posterolateral impression was advised following the Menzdorf classification (p < 0.001). Conclusion: Inter- and intraobserver reliability testing for classifying posterolateral tibial fractures resulted in moderate to good reliability. High-grade posterolateral tibial fractures should be identified, selective treatment should be considered as they are associated with higher revision rates after ACL reconstruction if left untreated.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 26 条
  • [21] Inter- and intra-observer variation of the Schatzker and AO/OTA classifications of tibial plateau fractures and a proposal of a new classification system
    Charalambous, C. P.
    Tryfonidis, M.
    Alvi, F.
    Moran, M.
    Fang, C.
    Samaraji, R.
    Hirst, P.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2007, 89 (04) : 400 - 404
  • [22] Evaluation of inter- and intra-observer reliability of current classification systems for subtrochanteric femoral fractures
    İmerci A.
    Aydogan N.H.
    Tosun K.
    European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (3) : 499 - 502
  • [23] Interobserver Reliability of Schatzker, AO Foundation-Orthopaedic Trauma Association, and Luo Classifications for Tibial Plateau Fractures: Does Three-Dimensional CT Improve Outcomes?
    Masouros, Panagiotis T.
    Mitrogiannis, George
    Antoniou, Georgia
    Chatzidaki, Christina
    Kourtzis, Dimitrios
    Garnavos, Christos
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (02)
  • [24] Inter-Observer and Intra-Observer Reliability Assessment of the Established Classification Systems for Periprosthetic Shoulder Fractures
    Wiethoelter, Mats
    Akguen, Doruk
    Plachel, Fabian
    Minkus, Marvin
    Karczewski, Daniel
    Braun, Karl
    Thiele, Kathi
    Becker, Luis
    Stoeckle, Ulrich
    Moroder, Philipp
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (09)
  • [25] Total talar fracture - Inter- and intra-observer reproducibility of two classification systems (Hawkins and AO) for central talar fractures
    Williams, T.
    Barba, N.
    Noailles, T.
    Steiger, V.
    Pineau, V.
    Carvalhana, G.
    Le Jacques, B.
    Clave, A.
    Huten, D.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (04) : S56 - S65
  • [26] Effect of clinician's experience and expertise on the inter- and intra-observer reliability of the computed tomography-based classification systems in posterior malleolus fractures
    Cirdi, Yigit Umur
    Demirel, Mehmet
    Kayaalp, Mahmut Enes
    Ozturk, Ramazan Ilter
    Bozoglan, Muhammet
    Salvi, Andrea Giordano
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2024, 58 (03)