Three-Terminal Lines Fault Location Using Two Main Terminals Data in the Presence of Renewable Energy Sources

被引:13
作者
Panahi, Habib [1 ]
Sanaye-Pasand, Majid [1 ]
Davarpanah, Mahdi [1 ]
机构
[1] Univ Tehran, Coll Engn, Sch Elect & Comp Engn, Tehran 14395515, Iran
关键词
Fault location; Circuit faults; Harmonic analysis; Impedance; Power system harmonics; Voltage; Renewable energy sources; healthy phase; medium voltage (MV) systems; renewable energy source (RES); three-terminal lines; TRANSMISSION-LINES; VOLTAGE; SCHEME;
D O I
10.1109/TSG.2022.3216908
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Penetration of renewable energy sources (RESs) in power systems is increased considerably and fault location algorithms face considerable problems with the presence of RESs. Also, the third terminal of three-terminal lines is expanded as a cost-effective solution to energize the remote areas of medium voltage (MV) systems, while its data may not be measured and easily available. In addition, in cases where this data is obtainable, due to the excessive harmonics of the inverter-based resources (IBRs) in that terminal, the measured data includes high error. Therefore, providing a method for fault location in three-terminal lines in the presence of RESs is challenging. This paper proposes an accurate method to identify the fault location on these lines incorporating RESs without requiring the third terminal data. Due to current transformers saturation and transient response of capacitive voltage transformers, the fault location based on the faulted phase data contains significant errors. The proposed method combines both the faulty and healthy phases data to improve the accuracy of fault location. Its performance is evaluated on a MV system for different scenarios including various fault resistances, locations and types, and third terminal integration of RESs. The obtained results confirm superiority of the proposed method.
引用
收藏
页码:2085 / 2095
页数:11
相关论文
共 51 条
  • [1] Dynamic protection of power systems with high penetration of renewables: A review of the traveling wave based fault location techniques
    Aftab, Mohd Asim
    Hussain, S. M. Suhail
    Ali, Ikbal
    Ustun, Taha Selim
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 114
  • [2] Preventing maloperation of distance protection due to CCVT transients
    Ahmadi, Seyed-Alireza
    Sanaye-Pasand, Majid
    Davarpanah, Mahdi
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (13) : 2828 - 2835
  • [3] [Anonymous], 2014, 5192014 IEEE
  • [4] [Anonymous], 2015, C371142014 IEEE
  • [5] A Traveling-Wave-Based Methodology for Wide-Area Fault Location in Multiterminal DC Systems
    Azizi, Sadegh
    Sanaye-Pasand, Majid
    Abedini, Moein
    Hasani, Abbas
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (06) : 2552 - 2560
  • [6] Sensitivity Analysis of Voltage Sag Based Fault Location With Distributed Generation
    Chen, Po-Chen
    Malbasa, Vuk
    Dong, Yimai
    Kezunovic, Mladen
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (04) : 2098 - 2106
  • [7] Impedance-Based Fault Location in Transmission Networks: Theory and Application
    Das, Swagata
    Santoso, Surya
    Gaikwad, Anish
    Patel, Mahendra
    [J]. IEEE ACCESS, 2014, 2 : 537 - 557
  • [8] Dynamic Modeling and Performance Analysis of a Grid-Connected Current-Source Inverter-Based Photovoltaic System
    Dash, Prajna Paramita
    Kazerani, Mehrdad
    [J]. IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2011, 2 (04) : 443 - 450
  • [9] A Saturation Suppression Approach for the Current Transformer-Part I: Fundamental Concepts and Design
    Davarpanah, Mahdi
    Sanaye-Pasand, Majid
    Iravani, Reza
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (03) : 1928 - 1935
  • [10] De Pereira CE, 2004, IEEE T POWER DELIVER, V19, P570, DOI [10.1109/TPWRD.2004.824391, 10.1109/TWPRD.2004.824391]