A phoswich alpha/beta detector for monitoring in the site of Fukushima Daiichi Nuclear Power Station

被引:8
作者
Morishita, Yuki [1 ]
Takasaki, Koji [1 ]
Kitayama, Yoshiharu [1 ]
Tagawa, Akihiro [1 ]
Shibata, Takuya [1 ]
Hoshi, Katsuya [2 ]
Kaneko, Junichi H. [3 ]
Higuchi, Mikio [3 ]
Oura, Masatoshi [4 ]
机构
[1] Japan Atom Energy Agcy, Collaborat Labs Adv Decommissioning Sci, 790-1 Motooka Ohtsuka, Fukushima 9791151, Japan
[2] Japan Atom Energy Agcy, Nucl Fuel Cycle Engn Labs, 4-33 Muramatsu, Tokai, Ibaraki 3191194, Japan
[3] Hokkaido Univ, Grad Sch Engn, Kita 8,Nishi 5,Kita Ku, Sapporo, Hokkaido 0600808, Japan
[4] Tokyo Elect Power Co Holdings Inc, 1-1-3 Uchisaiwai Cho,Chiyoda Ku, Tokyo 1008560, Japan
关键词
Fukushima Daiichi Nuclear Power Station; Phoswich detector; Alpha and beta emitting radionuclides; Radon-222; SCINTILLATORS;
D O I
10.1016/j.radmeas.2022.106896
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Alpha contamination and high concentrations of beta contamination can be found inside the reactor buildings at the Fukushima Daiichi Nuclear Power Station (FDNPS). This study proposes a newly developed phoswich alpha/ beta detector that can discriminate alpha and beta particles emitted from the alpha and beta contaminations in the FDNPS site. The phoswich alpha/beta detector is made up of two layers of scintillators that detect alpha and beta particles. The first layer is an octagonal, 50 mm diameter, 40-mu m-thick plastic scintillator that measures alpha particles, while the second layer is an octagonal, 50 mm diameter, 50-mu m-thick Gd2Si2O7 (GPS) scintillator that measures beta particles. The combination of the two scintillators improves the ability to distinguish between alpha and beta particles. The two layers of scintillators were optically coupled to an 8 x 8 multianode photo -multiplier tube (MA-PMT) with 50 mm x 50 mm through a 3-mm-thick light guide (glass plate). An eight -channel 14-bit 500 MS/s digitizer was fed with four output signals. Python programming was used to analyze the collected voltage waveforms. The pulse shape discrimination (PSD) method was used to detect alpha particles in high beta particle and high gamma-ray (comparable to gamma-ray dose rate near the FDNPS reactor building) environments. Due to a 23.3% full width at half maximum (FWHM) energy resolution for alpha particles, the detector can be used to distinguish between nuclear fuel materials such as plutonium and its radon progeny (Po -214). Moreover, the detector could distinguish alpha particles from 137Cs gamma rays with a dose rate back-ground up to 9.0 mSv/h. It is the first to demonstrate that the developed phoswich detector can be used to discriminate and measure alpha and beta particles of the actual contaminated FDNPS samples. As a result, this detector will be effective as an air monitoring device for alpha and beta radionuclide contamination measure-ment in real time.
引用
收藏
页数:10
相关论文
共 24 条
[1]   Radiation-resistant composite scintillators based on GSO and GPS grains [J].
Boyarintsev, A. Yu. ;
Galunov, N. Z. ;
Gerasymov, Ia. V. ;
Karavaeva, N. L. ;
Krech, A. V. ;
Levchuk, L. G. ;
Popov, V. F. ;
Sidletskiy, O. Ts. ;
Sorokin, P. V. ;
Tarasenko, O. A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 841 :124-129
[2]   Optical filtering based neutron/γ-ray discrimination in a phoswich detector [J].
Cirillo, A. ;
Zorloni, G. ;
Caresana, M. .
RADIATION MEASUREMENTS, 2021, 146 (146)
[3]  
Engelbrecht R, 2020, HANDBOOK OF RADIOACTIVITY ANALYSIS, VOL 2: RADIOANALYTICAL APPLICATIONS, 4TH EDITION, P1, DOI 10.1016/B978-0-12-814395-7.00001-5
[4]   Performance testing of continuous air monitors for alpha-emitting radionuclides [J].
Hoover, MD ;
Newton, GJ .
RADIATION PROTECTION DOSIMETRY, 1998, 79 (1-4) :499-504
[5]  
kaihara Akihisa, 2002, HIRACHIHYORON, V82
[6]   Thermal Neutron Discrimination Using a Novel Phoswich Detector of Gd3Ga3Al2O12:Ce,B and CsI:Tl Single Crystals [J].
Kalyani ;
Tyagi, Mohit ;
Rawat, Sheetal ;
Singh, Awadh K. ;
Patel, Tarun ;
Sarkar, P. S. ;
Desai, Shraddha S. ;
Kumar, G. Anil .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (11) :2415-2420
[7]  
Knoll G.F., 2010, Radiation detection and measurement
[8]   Scintillation Properties and α-ray Detection Capabilities of Thin-film Plastic Scintillators [J].
Koshimizu, Masanori ;
Yanagida, Takayuki ;
Kamishima, Ryoji ;
Fujimoto, Yutaka ;
Asai, Keisuke .
SENSORS AND MATERIALS, 2019, 31 (04) :1233-1239
[9]   Organic scintillator-based alpha/beta detector for radiological decontamination [J].
Morishita, Y. ;
Di Fulvio, A. ;
Clarke, S. D. ;
Kearfot, K. J. ;
Pozz, S. A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 935 :207-213
[10]   Development of a portable alpha-beta-gamma radioactive material continuous air-monitoring system [J].
Morishita, Yuki .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1027