Evaluating Fire Performance: An Experimental Comparison of Dovetail Massive Wooden Board Elements and Cross-Laminated Timber

被引:5
|
作者
Ilgin, Hueseyin Emre [1 ]
Karjalainen, Markku [1 ]
Alanen, Mika [1 ]
Malaska, Mikko [1 ]
机构
[1] Tampere Univ, Fac Built Environm, POB 600, FI-33014 Tampere, Finland
来源
FIRE-SWITZERLAND | 2023年 / 6卷 / 09期
基金
欧盟地平线“2020”;
关键词
dovetail massive wooden board elements; CLT; fire performance; char depth; charring rate; PANELS;
D O I
10.3390/fire6090352
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
The use of adhesives and metal connectors is vital in engineered wood product (EWP) composition. However, the utilization of adhesives poses sustainability and recyclability challenges due to the emission of toxic gases. Similarly, metal fasteners negatively impact the disposal, reusability, and recyclability of EWPs. An alternative solution that exclusively employs pure wood, known as dovetail massive wooden board elements (DMWBEs), eliminates the need for adhesives and metal fasteners. This paper presents an experimental comparative assessment of the fire/charring performance of DMWBEs and cross-laminated timber (CLT). Model-scale test specimens measuring 200 mm in thickness, 950 mm in width, and 950 mm in length were vertically tested according to EN 1363-1. The charring behavior of DMWBEs closely resembled that of solid timber, with only a slight increase in the charring rate. Charring primarily occurred in the third lamella layer out of five, with no observable flames or hot gases on the unexposed side. The dovetail detail effectively prevented char fall-off with the tested lamella thickness. CLT specimens exhibited a notable rise in the charring rate due to the fall-off of the first lamellae layer.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Experimental analysis of cross-laminated timber panels in fire
    Frangi, Andrea
    Fontana, Mario
    Hugi, Erich
    Joebstl, Robert
    FIRE SAFETY JOURNAL, 2009, 44 (08) : 1078 - 1087
  • [2] Fire behaviour of cross-laminated timber
    Klippel, Michael
    Frangi, Andrea
    BAUTECHNIK, 2016, 93 (08) : 567 - 572
  • [3] Monitoring Moisture Performance of Cross-Laminated Timber Building Elements during Construction
    Schmidt, Evan
    Riggio, Mariapaola
    BUILDINGS, 2019, 9 (06)
  • [4] Experimental determination of the charring rate of cross-laminated timber panels
    Alanen, Mika
    Malaska, Mikko
    Salminen, Mikko
    Paavola, Pyry
    Pajunen, Sami
    FIRE SAFETY JOURNAL, 2024, 146
  • [5] Experimental and numerical analysis on fire behaviour of loaded cross-laminated timber panels
    Wang, Yuexiang
    Zhang, Jin
    Mei, Fang
    Liao, Jianan
    Li, Weibin
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (01) : 22 - 36
  • [6] Ballistic performance of Cross-laminated Timber (CLT)
    Sanborn, K.
    Gentry, T. R.
    Koch, Z.
    Valkenburg, A.
    Conley, C.
    Stewart, L. K.
    INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2019, 128 : 11 - 23
  • [7] Thermo-energetic performance of wooden dwellings: Benefits of cross-laminated timber in Brazilian climates
    Nunes, Gustavo
    de Melo Moura, Jorge Daniel
    Guths, Saulo
    Atem, Camila
    Giglio, Thalita
    JOURNAL OF BUILDING ENGINEERING, 2020, 32
  • [8] Experimental modal analysis of a cross-laminated timber slab
    Kawrza, M.
    Furtmueller, T.
    Adam, C.
    Maderebner, R.
    MATERIALS TODAY-PROCEEDINGS, 2022, 62 : 2611 - 2616
  • [9] Influence of Wooden Board Strength Class on the Performance of Cross-laminated Timber Plates Investigated by Means of Full-field Deformation Measurements
    Hochreiner, G.
    Fuessl, J.
    Serrano, E.
    Eberhardsteiner, J.
    STRAIN, 2014, 50 (02) : 161 - 173
  • [10] Numerical Analysis of Cross-Laminated Timber (CLT) Wall Panels Under Fire
    Yasir, Muhammad
    Ruane, Kieran
    Jaksic, Vesna
    WOOD & FIRE SAFETY 2024, WFS 2024, 2024, : 27 - 35