Hemodynamic parameters at rest predicting exercise capacity in patients supported with left ventricular assist device

被引:0
作者
Kato, Hirotoshi [1 ]
Iwahana, Togo [1 ]
Ono, Ryohei [2 ]
Okada, Sho [1 ]
Matsumiya, Goro [2 ]
Kobayashi, Yoshio [1 ]
机构
[1] Chiba Univ, Dept Cardiovasc Med, Grad Sch Med, 1-8-1 Inohana,Chuo Ku, Chiba 2608677, Japan
[2] Chiba Univ, Dept Cardiovasc Surg, Grad Sch Med, Chiba, Japan
基金
日本学术振兴会;
关键词
Left ventricular assist device; Exercise capacity; Hemodynamic; HEART-FAILURE PATIENTS; PUMP SPEED; AORTIC-INSUFFICIENCY; IMPLANTATION; MANAGEMENT; PHYSIOLOGY; OUTPUT;
D O I
10.1007/s10047-023-01388-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Left ventricular assist devices improve prognosis and quality of life, but exercise capacity remains limited in most patients after device implantation. Left ventricular assist device optimization through right heart catheterization reduces device-related complications. However, hemodynamic parameters associated with exercise capacity under optimized conditions. The aim of this study was to elucidate the predictors of exercise capacity from hemodynamic parameters at rest after left ventricular assist device optimization. We retrospectively reviewed 24 patients who underwent a ramp test with right heart catheterization, echocardiography and cardiopulmonary exercise testing more than 6 months after left ventricular assist device implantation. Pump speed was optimized to a lower setting that achieved right atrial pressure < 12 mmHg, pulmonary capillary wedge pressure < 18 mmHg, and cardiac index > 2.2 L/min/m(2), then exercise capacity was assessed by cardiopulmonary exercise testing. After left ventricular assist device optimization, the mean right atrial pressure, pulmonary capillary wedge pressure, cardiac index, and peak oxygen consumption were 7 +/- 5 mmHg, 10 +/- 7 mmHg, 2.7 +/- 0.5 L/min/m(2), and 13.2 +/- 3.0 mL/min/kg, respectively. Pulse pressure, stroke volume, right atrial pressure, mean pulmonary artery pressure, and pulmonary capillary wedge pressure were significantly associated with peak oxygen consumption. Multivariate linear regression analysis of factors predicting peak oxygen consumption revealed that pulse pressure, right atrial pressure, and aortic insufficiency remained independent predictors (beta = 0.401, p = 0.007; beta = - 0.558, p < 0.001; beta = - 0.369, p = 0.010, respectively). Our findings suggests that cardiac reserve, volume status, right ventricular function, and aortic insufficiency predict exercise capacity in patients with a left ventricular assist device.
引用
收藏
页码:7 / 14
页数:8
相关论文
共 40 条
[31]   Management of ventricular arrhythmias in patients with ventricular assist devices [J].
Pedrotty, Dawn M. ;
Rame, Jesus E. ;
Margulies, Kenneth B. .
CURRENT OPINION IN CARDIOLOGY, 2013, 28 (03) :360-368
[32]   Continuous Flow Left Ventricular Assist Device Improves Functional Capacity and Quality of Life of Advanced Heart Failure Patients [J].
Rogers, Joseph G. ;
Aaronson, Keith D. ;
Boyle, Andrew J. ;
Russell, Stuart D. ;
Milano, Carmelo A. ;
Pagani, Francis D. ;
Edwards, Brooks S. ;
Park, Soon ;
John, Ranjit ;
Conte, John V. ;
Farrar, David J. ;
Slaughter, Mark S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (17) :1826-1834
[33]   Long-term use of a left ventricular assist device for end-stage heart failure [J].
Rose, EA ;
Gelijns, AC ;
Moskowitz, AJ ;
Heitjan, DF ;
Stevenson, LW ;
Dembitsky, W ;
Long, JW ;
Ascheim, DD ;
Tierney, AR ;
Levitan, RG ;
Watson, JT ;
Meier, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (20) :1435-1443
[34]   Determinants of Improvement in Cardiopulmonary Exercise Testing After Left Ventricular Assist Device Implantation [J].
Rosenbaum, Andrew N. ;
Dunlay, Shannon M. ;
Pereira, Naveen L. ;
Allison, Thomas G. ;
Maltais, Simon ;
Stulak, John M. ;
Joyce, Lyle D. ;
Kushwaha, Sudhir S. .
ASAIO JOURNAL, 2018, 64 (05) :610-615
[35]   Changes in Total Cardiac Output and Oxygen Extraction During Exercise in Patients Supported With an HVAD Left Ventricular Assist Device [J].
Schmidt, Thomas ;
Bjarnason-Wehrens, Birna ;
Mommertz, Stephanie ;
Hannig, Meike ;
Schulte-Eistrup, Sebastian ;
Willemsen, Detlev ;
Reiss, Nils .
ARTIFICIAL ORGANS, 2018, 42 (07) :686-694
[36]   Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist Device [J].
Slaughter, Mark S. ;
Rogers, Joseph G. ;
Milano, Carmelo A. ;
Russell, Stuart D. ;
Conte, John V. ;
Feldman, David ;
Sun, Benjamin ;
Tatooles, Antone J. ;
Delgado, Reynolds M., III ;
Long, James W. ;
Wozniak, Thomas C. ;
Ghumman, Waqas ;
Farrar, David J. ;
Frazier, O. Howard .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (23) :2241-2251
[37]   Noninvasive blood pressure measurement in patients with continuous-flow left ventricular assist devices [J].
Tanaka, Aiko ;
Kiriyama, Yuki ;
Kubo, Naoko ;
Sakaguchi, Ryota ;
Uchiyama, Akinori ;
Fujino, Yuji .
JOURNAL OF ARTIFICIAL ORGANS, 2023, 26 (02) :160-164
[38]   Aortic Insufficiency During Contemporary Left Ventricular Assist Device Support Analysis of the INTERMACS Registry [J].
Truby, Lauren K. ;
Garan, A. Reshad ;
Givens, Raymond C. ;
Wayda, Brian ;
Takeda, Koji ;
Yuzefpolskaya, Melana ;
Colombo, Paolo C. ;
Naka, Yoshifumi ;
Takayama, Hiroo ;
Topkara, Veli K. .
JACC-HEART FAILURE, 2018, 6 (11) :951-960
[39]   Lvad pump speed increase is associated with increased peak exercise cardiac output and vo2, postponed anaerobic threshold and improved ventilatory efficiency [J].
Vignati, Carlo ;
Apostolo, Anna ;
Cattadori, Gaia ;
Farina, Stefania ;
Del Torto, Alberico ;
Scuri, Silvia ;
Gerosa, Gino ;
Bottio, Tomaso ;
Tarzia, Vincenzo ;
Bejko, Jonida ;
Sisillo, Erminio ;
Nicoli, Flavia ;
Sciomer, Susanna ;
Alamanni, Francesco ;
Paolillo, Stefania ;
Agostoni, Piergiuseppe .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 230 :28-32
[40]   Fluid Dynamics in the HeartMate 3: Influence of the Artificial Pulse Feature and Residual Cardiac Pulsation [J].
Wiegmann, Lena ;
Thamsen, Bente ;
de Zelicourt, Diane ;
Granegger, Marcus ;
Boes, Stefan ;
Daners, Marianne Schmid ;
Meboldt, Mirko ;
Kurtcuoglu, Vartan .
ARTIFICIAL ORGANS, 2019, 43 (04) :363-376