摘要
The purpose of this study was to clarify the discoloration of fiber-reinforced composite resin (FRC) disc materials. The color differences (.Es) of three CAD/CAM disc materials, FRC with different fiber orientations, composite resin, and polyether-ether-ketones were evaluated after month-long immersion in water, coffee, and curry. The.Es of all materials after coffee and curry immersion increased with increasing immersion periods, while those after water immersion barely increased. FRC exhibited a smaller color difference and water sorption value than composite resin and a greater color difference and water sorption value than polyether-ether-ketones. The.Es after coffee immersion were significantly correlated with the water sorption value. The.E of FRC with fiber orientations perpendicular to the surface was greater than that of FRC with fiber orientations parallel to the surface, likely due to greater exposure of the matrix-fiber interface. This result suggested that the fiber orientations of FRC affected the discoloration.
引用
收藏
页码:64 / 71
页数:8
相关论文
共 50 条
  • [31] Effect of training on time efficiency and marginal adaptation of computer-aided design/computer-aided manufacturing crowns among dental students
    Tan, Ying Yin
    Ho, Ting Khee
    Goo, Chui Ling
    EUROPEAN JOURNAL OF DENTAL EDUCATION, 2022, 26 (03) : 468 - 474
  • [32] Computer-Aided Design/Computer-Aided Manufacturing Milling of Allogeneic Blocks Following Three-Dimensional Maxillofacial Graft Planning
    Gialain, Ivan Onone
    Pinhata-Baptista, Otavio Henrique
    Paraiso Cavalcanti, Marcelo Gusmao
    Gonzalez Cortes, Arthur Rodriguez
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (05) : E413 - E415
  • [33] Degradation of Computer-aided Design/Computer-aided Manufacturing Composites by Dietary Solvents: An Optical Three-dimensional Surface Analysis
    Munusamy, S. M.
    Yap, A. U.
    Ching, H. L.
    Yahya, N. A.
    OPERATIVE DENTISTRY, 2020, 45 (04) : E176 - E184
  • [34] Effect of Different Computer-aided Design/Computer-aided Manufacturing (CAD/CAM) Materials and Thicknesses on the Fracture Resistance of Occlusal Veneers
    Andrade, J. P.
    Stona, D.
    Bittencourt, H. R.
    Borges, G. A.
    Burnett Junior, L. H.
    Spohr, A. M.
    OPERATIVE DENTISTRY, 2018, 43 (05) : 539 - 548
  • [35] RADIOPACITY ANALYSIS OF SOME CHAIRSIDE COMPUTER-AIDED DESIGN-COMPUTER-AIDED MANUFACTURING MILLING MATERIALS
    Varvara, Adrian Mina
    Gasparik, Cristina
    Culic, Bogdan
    Bondor, Cosmina Ioana
    Varvara, Elena Bianca
    Furtos, Gabriel
    Moldovan, Marioara
    Dudea, Diana
    STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2019, 64 (01): : 161 - 172
  • [36] Comparison of Resin Composite and Biodentine Cervical Marginal Elevation on the Marginal Gap of Two Computer-Aided Design/Computer-Aided Manufacture Endocrown Materials: In Vitro Study
    Alqahtani, Waleed
    Yousuf, Salah A.
    Metwally, Mohamed F.
    Haggag, Khaled M.
    Barakat, Ali
    Alghamdi, Abdelrahman
    Almadani, Roua Mohammed Y.
    Alsalmi, Hajer Aiydh Hamed
    Khamis, Adnan Madani Mohammed
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2023, 13 (06) : 765 - 772
  • [37] A Novel Application of Computer-Aided Design and Manufacturing for Reduction Cranioplasty
    Dorafshar, Amir
    Fisher, Mark
    Borsuk, Daniel
    Fishman, Elliot
    Ahn, Edward
    JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (01) : 172 - 176
  • [38] The Use of Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) Technology for Zirconia Crowns After LaserAssisted Crown Lengthening and Retraction: A Case Report
    Valiathan, Mohan
    Mari, Ranjith
    Rudhra, K.
    Fiona, J. Angelin
    Hussain, Sajid
    Balaji, Anitha
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (06)
  • [39] Frequency of Technical Complications in Fixed Implant Prosthesis: The Effect of Prosthesis Screw Emergence Correction by Computer-Aided Design/Computer-Aided Manufacturing
    Anitua, Eduardo
    Flores, Carlos
    Pinas, Laura
    Hamdan Alkhraisat, Mohammad
    JOURNAL OF ORAL IMPLANTOLOGY, 2018, 44 (06) : 427 - 431
  • [40] Evaluation of marginal accuracy of polyetheretherketone and zirconia copings fabricated using computer-aided design/computer-aided manufacturing technique: An in vitro study
    Jangade, Manish
    Sharma, Ranu
    Sudharson, Nishanth A.
    Jain, Raj
    Sahu, Shailendra Kumar
    Dani, Anurag
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2025, 25 (01): : 95 - 101