Distributed fiber optic strain sensing in axially loaded glued-in steel rods in glued-laminated timber

被引:3
作者
Ernewein, Benjamin [1 ]
Woods, Joshua E. [2 ]
机构
[1] Univ British Columbia, Dept Civil Engn, Vancouver, BC V6T 1Z4, Canada
[2] Queens Univ, Dept Civil Engn, Intelligent Infrastruct Monitoring, Ellis Hall, Kingston, ON K7L 3N6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Mass timber; Connections; Glued-in-rods; Glued-laminated timber; Distributed strain sensing; Volkersen theory; Bond-slip; Structural testing; PULL-OUT BEHAVIOR; PART II; GLULAM PARALLEL; GFRP RODS; JOINTS; CONNECTIONS; CAPACITY; STRENGTH; FATIGUE; SINGLE;
D O I
10.1016/j.conbuildmat.2023.132020
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The rise in popularity of mass timber structures globally has increased the demand for high-performance timber connections. Glued-in rod connections which are advantageous compared to other dowel-type connections because of their high strength and stiffness, have been the subject of extensive research in the literature; However, the lack of an in-depth understanding of their behavior and a uniform set of guidelines for their design continues to limit the use of glued-in rods in practice. To develop an improved understanding of the behavior of glued-in rod connections this paper examines, for the first time, the use of distributed fiber optic sensors to measure the complete strain distribution along the length of a glued-in rod connection. Axial pullout tests were conducted on twenty-five glued-in rod connections in glued-laminated timber with varying embedment lengths and glue-line thicknesses. Results of the study demonstrate the ability of fiber optic sensors to capture the full strain distribution along the length of the steel rod and along the epoxy-adhesive interface, enabling the study of localized behavior that would be difficult to measure using conventional strain gauges. In addition, results demonstrate the ability of distributed fiber optic strain sensors to infer axial stress and force distributions along the length of a glued-in rod connection, which are compared with theoretical distributions from the Volkersen model, as well as measure bond-slip behavior.
引用
收藏
页数:13
相关论文
共 66 条
[1]   Experimental investigations of glued-in rod connections in CLT [J].
Ayansola, Gbenga Solomon ;
Tannert, Thomas ;
Vallee, Till .
CONSTRUCTION AND BUILDING MATERIALS, 2022, 324
[2]   Glued-in multiple steel rod connections in cross-laminated timber [J].
Ayansola, Gbenga Solomon ;
Tannert, Thomas ;
Vallee, Till .
JOURNAL OF ADHESION, 2022, 98 (06) :810-826
[3]   Glued-in rods in cross laminated timber - Numerical simulations and parametric studies [J].
Azinovic, Boris ;
Danielsson, Henrik ;
Serrano, Erik ;
Kramar, Miha .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 212 :431-441
[4]   Experimental investigation of the axial strength of glued-in rods in cross laminated timber [J].
Azinovic, Boris ;
Serrano, Erik ;
Kramar, Miha ;
Pazlar, Tomaz .
MATERIALS AND STRUCTURES, 2018, 51 (06)
[5]   Bonded-in rod connections for timber structures - development of design methods and test observations [J].
Bainbridge, R ;
Mettem, C ;
Harvey, K ;
Ansell, M .
INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2002, 22 (01) :47-59
[6]  
Baroth J., 2004, WORLD C TIMB ENG WCT
[7]  
Bengtsson C, 2002, Final report: GIROD-glued-in rods for timber structures
[8]   Experimental investigation of joints with multiple glued-in rods in glued-laminated timber under axial tensile loading [J].
Bouchard, Raphael ;
Salenikovich, Alexander ;
Frenette, Caroline ;
Bedard-Blanchet, Guillaume .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 293
[9]   Pull-out behaviour of steel rods bonded into timber [J].
Broughton, JG ;
Hutchinson, AR .
MATERIALS AND STRUCTURES, 2001, 34 (236) :100-109
[10]  
Buchanan A., 2001, P NZSEE C WAIR RES T