Optimum heparin dose in off-pump coronary artery bypass grafting: A systematic review and meta-analysis

被引:0
作者
Khalil, Mohamed A. [1 ,8 ]
Kaddoura, Rasha [2 ]
Omar, Amr S. [3 ,4 ,5 ]
Abohamar, Ahmed D. [6 ]
Izham, Mohamed [7 ]
机构
[1] Cairo Univ, Fac Med, Anesthesia Dept, Giza, Egypt
[2] Hamad Med Corp, Dept Clin Pharm, Doha, Qatar
[3] Hamad Med Corp, Heart Hosp, Dept Cardiothorac Surg, Cardiac Anesthesia & ICU, Doha, Qatar
[4] Beni Suef Univ, Dept Crit Care Med, Bani Suwayf, Egypt
[5] Weill Cornell Med Coll, Ar Rayyan, Qatar
[6] Tanta Univ, Fac Med, Anesthesia Dept, Tanta, Egypt
[7] Qatar Univ, Fac Pharm, Doha, Qatar
[8] Cairo Univ, Dept Anesthesiol, Giza 11562, Egypt
来源
PERFUSION-UK | 2024年 / 39卷 / 04期
关键词
heparin; activated clotting time; off-pump coronary artery bypass graft surgery; bleeding; hospital stay; ON-PUMP; CARDIOPULMONARY BYPASS; SURGERY; ANTICOAGULATION; MORTALITY; STATE;
D O I
10.1177/02676591231159506
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Off-pump coronary artery bypass grafting (OPCABG) was introduced many years ago aiming to reduce the known complications of conventional on-pump coronary surgeries. Heparin is required during the procedures, but the available protocols have diverse dosage regimens. The primary objective of this systematic review is to examine the effect of different heparin doses on the outcomes of OPCABG. Evidence acquisition MEDLINE and EMBASE were searched. Four reviewers identified eligible clinical trials. Two reviewers extracted data and independently assessed the risk of bias using Cochrane tool. The primary outcome was the activated clotting time (ACT) at three minutes. The secondary outcomes were proportion of patients requiring blood products and the length of hospital stay. An aggregate data approach was used. Evidence synthesis Three single-center randomized studies recruiting 256 patients were included. The studies compared low-dose (1.5-2 mg/kg) and high-dose (3 mg/kg) heparin boluses. The overall mean difference for ACT after three minutes between low- and high-dose heparin is - 126.16 (95% CI: - 142.19, - 110.14). The proportion of patients requiring blood products after surgery [odd ratio 1.27 (95% CI: 0.69, 2.32)] or the overall length of stay [mean difference -0.15 (95% CI: -0.84, 0.53)] did not differ between the heparin doses. Conclusions In OPCABG, high-dose compared with low-dose heparin did not affect the utilization of more blood products or increased the overall length of stay. Unsurprisingly, ACT values were higher in the high-dose heparin group. Larger and adequately powered randomized clinical trials are indicated to resolve the uncertainty.
引用
收藏
页码:675 / 683
页数:9
相关论文
共 34 条
  • [1] Factors associated with prolonged length of stay following cardiac surgery in a major referral hospital in Oman: a retrospective observational study
    Almashrafi, Ahmed
    Alsabti, Hilal
    Mukaddirov, Mirdavron
    Balan, Baskaran
    Aylin, Paul
    [J]. BMJ OPEN, 2016, 6 (06):
  • [2] Safety and efficacy of off-pump coronary artery bypass grafting
    Arom, KV
    Flavin, TF
    Emery, RW
    Kshettry, VR
    Janey, PA
    Petersen, RJ
    [J]. ANNALS OF THORACIC SURGERY, 2000, 69 (03) : 704 - 710
  • [3] Off-pump coronary artery bypass prevents visceral organ damage
    Bierbach, Benjamin
    Bomberg, Hagen
    Pritzer, Hartmut
    Prabhu, Sudesh
    Petzina, Rainer
    Kempski, Oliver
    Horstick, Georg
    Cremer, Jochen
    Hoffmann, Grischa
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 18 (06) : 717 - 726
  • [4] Borenstein M., 2009, Introduction to meta-analysis, P59
  • [5] Outcomes experience with off-pump coronary artery bypass surgery in women
    Brown, PP
    Mack, MJ
    Simon, AW
    Battaglia, S
    Tarkington, L
    Horner, S
    Culler, SD
    Becker, ER
    [J]. ANNALS OF THORACIC SURGERY, 2002, 74 (06) : 2113 - 2119
  • [6] Coronary artery bypass grafting with cardiopulmonary bypass versus off-pump cardiopulmonary bypass grafting: Does eliminating the pump reduce morbidity and cost?
    Bull, DA
    Neumayer, LA
    Stringham, JC
    Meldrum, P
    Affleck, DG
    Karwande, SV
    [J]. ANNALS OF THORACIC SURGERY, 2001, 71 (01) : 170 - 173
  • [7] Chakravarthy M, 2017, ANN CARD ANAESTH, V20, P8, DOI 10.4103/0971-9784.197818
  • [8] Heparin responsiveness during off-pump coronary artery bypass graft surgery: predictors and clinical implications
    Chun, Duk-hee
    Baik, Seong-wan
    Kim, So Yeon
    Shim, Jae Kwang
    Kim, Jong Chan
    Kwak, Young Lan
    [J]. ACTA PHARMACOLOGICA SINICA, 2011, 32 (01) : 133 - 138
  • [9] Is intraoperative measurement of coronary blood flow a good predictor of graft patency?
    D'Ancona, G
    Karamanoukian, HL
    Bergsland, J
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 20 (05) : 1075 - 1076
  • [10] Donias HW, 2003, HEART SURG FORUM, V6, P176