Effect of vertical facing wall on facade flame height of under-ventilated compartment fire with triangular opening

被引:6
作者
Zhang, Zijian [1 ,2 ]
Zhang, Xiaochun [1 ]
Chen, Linjie [1 ]
Zhou, Geyao [1 ]
Tao, Haowen [1 ]
Zhou, Lei [2 ]
Yang, Hua [3 ]
机构
[1] Guangdong Univ Technol, Sch Environm Sci & Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] Harbin Inst Technol, Sch Mech Engn & Automat, Shenzhen 518055, Guangdong, Peoples R China
[3] Jinan Fire & Rescue Detachment, Jinan 250000, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Spill fire plume; Under-ventilated compartment fire; Facade flame height; Triangular opening; Vertical facing wall; TEMPERATURE PROFILE; HEAT FLUXES; SPILL PLUME;
D O I
10.1016/j.tsep.2023.101667
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present paper investigated the evolution law of the facade flame height for under-ventilated compartment fires with triangular openings constrained by a vertical facing wall. Through a series of reduced-scale experiments, the hot gas temperature inside a compartment was measured by thermocouples, and the facade flame height was obtained by processing the sequential images of the facade flame recorded by a CCD camera. The results revealed that the vertical facing wall has little effect on the hot gas temperature inside the compartment, and the facade flame height is independent of the vertical facing wall when the distance between the triangular opening and the vertical facing wall (D) is relatively large, while the facade flame height is increased at a relatively small D. The facade flame height for triangular opening with a vertical facing wall is unable to be characterized by the classical model of the rectangular opening. Based on the balance of momentum and buoyancy at the opening, a characteristic length of L3 was proposed to describe the effect of a vertical facing wall. By introducing a correction factor kappa related to L3 and D, a new global model was finally established to predict the facade flame height for triangular openings with and without a vertical facing wall. This work extends the knowledge about the hazard of compartment fires involving triangular openings to the cases with a vertical facing wall.
引用
收藏
页数:9
相关论文
共 27 条
[1]   Studies on jatropha oil pool fire [J].
Chaudhary, Avinash ;
Gupta, Akhilesh ;
Kumar, Surendra .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 6 :104-127
[2]  
Coutin M., 2000, P 6 INT S FIR SAF SC, V6, P729, DOI [10.3801/IAFSS.FSS.6-729, DOI 10.3801/IAFSS.FSS.6-729]
[3]   Flame Heights in Turbulent Wall Fires with Significant Flame Radiation [J].
Delichatsios, Michael A. .
COMBUSTION SCIENCE AND TECHNOLOGY, 1984, 39 (1-6) :195-214
[4]   A new correlation for gas temperature inside a burning enclosure [J].
Delichatsios, Michael A. ;
Lee, Yee-Ping ;
Tofilo, Piotr .
FIRE SAFETY JOURNAL, 2009, 44 (08) :1003-1009
[5]   Fire spill plume from a compartment with dual symmetric openings under cross wind [J].
Gao, Wei ;
Liu, Naian ;
Delichatsios, Michael ;
Yuan, Xieshang ;
Bai, Yueling ;
Chen, Haixiang ;
Zhang, Linhe .
COMBUSTION AND FLAME, 2016, 167 :409-421
[6]   Global behaviors of enclosure fire and facade flame heights in normal and reduced atmospheric pressures at two altitudes [J].
Hu, L. H. ;
Tang, F. ;
Delichatsios, M. A. ;
Wang, Q. ;
Lu, K. H. ;
Zhang, X. C. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 56 (1-2) :119-126
[7]   Facade flame height and horizontal extending distance from opening of compartment fire with external sideward wind [J].
Hu, Longhua ;
Sun, Xiepeng ;
Zhang, Xiaolei ;
Ren, Fei .
PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2019, 37 (03) :3859-3867
[8]   Facade flame height ejected from an opening of fire compartment under external wind [J].
Hu, Longhua ;
Hu, Kaizhi ;
Ren, Fei ;
Sun, Xiepeng .
FIRE SAFETY JOURNAL, 2017, 92 :151-158
[9]   Ambient wind effect on combustion characteristics in compartment with simultaneous door and window opened [J].
Ji, Jie ;
Li, Man ;
Li, Kaiyuan ;
Yuan, Mengyuan ;
Sun, Jinhua .
ENERGY AND BUILDINGS, 2015, 105 :217-225
[10]  
Lee Y.-P., 2006, Heat fluxes and flame heights on external facades from enclosure fires