Effect of Scanning Acceleration on the Leakage Signal in Magnetic Flux Leakage Type of Non-destructive Testing

被引:2
作者
Zhang, Lintao [1 ]
Cameron, Ian M. [2 ]
Ledger, Paul D. [3 ]
Belblidia, Fawzi [2 ]
Pearson, Neil R. [4 ]
Charlton, Peter [5 ]
Sienz, Johann [2 ]
机构
[1] Swansea Univ, Coll Engn, Mat Adv Characterisat Ctr MACH1, Fabian Way, Swansea SA1 8EN, Wales
[2] Swansea Univ, Coll Engn, Adv Sustainable Mfg Technol ASTUTE 2020 Operat, Bay Campus,Fabian Way, Swansea SA1 8EN, Wales
[3] Swansea Univ, Coll Engn, Bay Campus,Fabian Way, Swansea SA1 8EN, Wales
[4] Eddyfi UK Ltd, Clos Llyn Cwm, Swansea Enterprise Pk, Swansea SA6 8QY, Wales
[5] Univ Wales Trinity St David, Mt Pleasant Campus, Swansea SA1 6ED, Wales
关键词
Non-destructive Testing (NDT); Magnetic flux leakge (MFL); Leakage signal (peak to peak); Scanning acceleration; INDUCED EDDY-CURRENT; 3D SIMULATION; INSPECTION; DEFECTS; FIELDS;
D O I
10.1007/s10921-023-00925-1
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This work investigates the influence of acceleration on the leakage signal in magnetic flux leakage type of non-destructive testing. The research is addressed through both designed experiments and simulations. The results showed that the leakage signal, represented by using peak to peak value, decreases between 15.1% and 26.6% under acceleration. The simulation results indicated that the main reason for the decrease is due to the difference in the distortion of the magnetic field for cases with and without acceleration, which is the result of the different eddy current distributions in the specimen. The findings will help to allow the optimisation of a magnetic flux leakage system to ensure that main defect features can be measured more accurately during the machine acceleration phase of scanning. It also shows the importance of conducting measurements at constant velocity, wherever possible.
引用
收藏
页数:13
相关论文
共 50 条
[31]   Magnetic Flux Leakage Testing for Steel Plate Using Pot-Shaped Excitation Structure [J].
Ou, Zhengyu ;
Han, Zandong ;
Du, Dong .
IEEE TRANSACTIONS ON MAGNETICS, 2022, 58 (09)
[32]   A Lift-Off-Tolerant Magnetic Flux Leakage Testing Method for Drill Pipes at Wellhead [J].
Wu, Jianbo ;
Fang, Hui ;
Li, Long ;
Wang, Jie ;
Huang, Xiaoming ;
Kang, Yihua ;
Sun, Yanhua ;
Tang, Chaoqing .
SENSORS, 2017, 17 (01)
[33]   Linearization of the lift-off effect for magnetic flux leakage based on Fourier transform [J].
Wang, Jie ;
Li, Erlong ;
Wu, Jianbo ;
Xu, Xianyou .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (06)
[34]   A Novel Defect Quantification Method Utilizing Multi-Sensor Magnetic Flux Leakage Signal Fusion [J].
Liu, Wenlong ;
Ren, Lemei ;
Tian, Guansan .
SENSORS, 2024, 24 (20)
[35]   Three-dimensional magnetic flux leakage signal analysis and imaging method for tank floor defect [J].
Peng, Lisha ;
Huang, Songling ;
Wang, Shen ;
Zhao, Wei .
JOURNAL OF ENGINEERING-JOE, 2018, 2018 (17) :1865-1870
[36]   Magnetic flux leakage testing based on the dual testing probes resisting the negative effects of lift-off perturbations [J].
Hao, Shuai ;
Shi, Peng-Peng ;
Su, San-Qing .
ENGINEERING FRACTURE MECHANICS, 2025, 321
[37]   A novel broken wire evaluation method for bridge cable magnetic flux leakage testing under lift-off uncertainty [J].
Sun, Lingsi ;
Wu, Xinjun ;
Ouyang, Quan ;
Wang, Junjie .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2023, 570
[38]   Analysis of non-destructive testing of three-dimensional braided composites using scanning SQUID NDT [J].
Wan Zhenkai ;
Wang Zhangang ;
Guo Jianmin .
INSIGHT, 2014, 56 (05) :246-251
[39]   Non-Destructive Testing of Pipe Conveyor Belts Using Glass-Coated Magnetic Microwires [J].
Semrad, Karol ;
Draganova, Katarina .
SUSTAINABILITY, 2022, 14 (14)
[40]   Signal extraction using ensemble empirical mode decomposition and sparsity in pipeline magnetic flux leakage nondestructive evaluation [J].
Chen, Liang ;
Li, Xing ;
Li, Xun-bo ;
Huang, Zuo-ying .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (02)