Effect of Scanning Acceleration on the Leakage Signal in Magnetic Flux Leakage Type of Non-destructive Testing

被引:2
|
作者
Zhang, Lintao [1 ]
Cameron, Ian M. [2 ]
Ledger, Paul D. [3 ]
Belblidia, Fawzi [2 ]
Pearson, Neil R. [4 ]
Charlton, Peter [5 ]
Sienz, Johann [2 ]
机构
[1] Swansea Univ, Coll Engn, Mat Adv Characterisat Ctr MACH1, Fabian Way, Swansea SA1 8EN, Wales
[2] Swansea Univ, Coll Engn, Adv Sustainable Mfg Technol ASTUTE 2020 Operat, Bay Campus,Fabian Way, Swansea SA1 8EN, Wales
[3] Swansea Univ, Coll Engn, Bay Campus,Fabian Way, Swansea SA1 8EN, Wales
[4] Eddyfi UK Ltd, Clos Llyn Cwm, Swansea Enterprise Pk, Swansea SA6 8QY, Wales
[5] Univ Wales Trinity St David, Mt Pleasant Campus, Swansea SA1 6ED, Wales
关键词
Non-destructive Testing (NDT); Magnetic flux leakge (MFL); Leakage signal (peak to peak); Scanning acceleration; INDUCED EDDY-CURRENT; 3D SIMULATION; INSPECTION; DEFECTS; FIELDS;
D O I
10.1007/s10921-023-00925-1
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This work investigates the influence of acceleration on the leakage signal in magnetic flux leakage type of non-destructive testing. The research is addressed through both designed experiments and simulations. The results showed that the leakage signal, represented by using peak to peak value, decreases between 15.1% and 26.6% under acceleration. The simulation results indicated that the main reason for the decrease is due to the difference in the distortion of the magnetic field for cases with and without acceleration, which is the result of the different eddy current distributions in the specimen. The findings will help to allow the optimisation of a magnetic flux leakage system to ensure that main defect features can be measured more accurately during the machine acceleration phase of scanning. It also shows the importance of conducting measurements at constant velocity, wherever possible.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Effect of Scanning Acceleration on the Leakage Signal in Magnetic Flux Leakage Type of Non-destructive Testing
    Lintao Zhang
    Ian M. Cameron
    Paul D. Ledger
    Fawzi Belblidia
    Neil R. Pearson
    Peter Charlton
    Johann Sienz
    Journal of Nondestructive Evaluation, 2023, 42
  • [2] Multi-Objective Optimization of a Magnetic Circuit for Magnetic Flux Leakage-Type Non-destructive Testing
    Parra-Raad, Jaime A.
    Roa-Prada, Sebastian
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2016, 35 (01) : 1 - 12
  • [3] Effects of excitation system on the performance of magnetic-flux-leakage-type non-destructive testing
    Chang, Yu
    Jiao, Jingpin
    Li, Guanghai
    Liu, Xiucheng
    He, Cunfu
    Wu, Bin
    SENSORS AND ACTUATORS A-PHYSICAL, 2017, 268 : 201 - 212
  • [4] Multi-Objective Optimization of a Magnetic Circuit for Magnetic Flux Leakage-Type Non-destructive Testing
    Jaime A. Parra-Raad
    Sebastián Roa-Prada
    Journal of Nondestructive Evaluation, 2016, 35
  • [5] A model for magnetic flux leakage signal predictions
    Mandache, C
    Clapham, L
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (20) : 2427 - 2431
  • [6] Determining the Effect of Velocity on Sensor Selection and Position in Non-Destructive Testing With Magnetic Flux Leakage Method: A Pipe Inspection Gauge Design Study With ANSYS Maxwell
    Coramik, Mustafa
    Citak, Hakan
    Ege, Yavuz
    Bicakci, Sabri
    Gunes, Huseyin
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [7] Non-Destructive Evaluation of Reinforced Concrete Structures with Magnetic Flux Leakage and Eddy Current Methods-Comparative Analysis
    Frankowski, Pawel Karol
    Majzner, Piotr
    Maka, Marcin
    Stawicki, Tomasz
    APPLIED SCIENCES-BASEL, 2024, 14 (24):
  • [9] A Review of Magnetic Flux Leakage Nondestructive Testing
    Feng, Bo
    Wu, Jianbo
    Tu, Hongming
    Tang, Jian
    Kang, Yihua
    MATERIALS, 2022, 15 (20)
  • [10] The Application of Magnetic Shielding Effect in Drill Pipe Magnetic Leakage Flux Testing
    Ma Yilai
    Lin Li
    Jiang Kaiwen
    Zhao Xulin
    2013 FIFTH INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION (ICMTMA 2013), 2013, : 1135 - 1138