LSTM-Based IoT-Enabled CO2 Steady-State Forecasting for Indoor Air Quality Monitoring

被引:20
作者
Zhu, Yingbo [1 ]
Al-Ahmed, Shahriar Abdullah [1 ]
Shakir, Muhammad Zeeshan [1 ]
Olszewska, Joanna Isabelle [1 ]
机构
[1] Univ West Scotland, Sch Comp Engn & Phys Sci, Paisley PA1 2BE, Scotland
关键词
IoT; LSTM; AI; deep learning; CO2; IAQ monitoring; smart living; CARBON-DIOXIDE; VENTILATION; EXPOSURE; OFFICE; RISK;
D O I
10.3390/electronics12010107
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Whether by habit or necessity, people tend to spend most of their time indoors. Built-up Carbon dioxide (CO2) can lead to a series of negative health effects such as nausea, headache, fatigue, and so on. Thus, indoor air quality must be monitored for a variety of health reasons. Various air quality monitoring systems are available on the market. However, since they are expensive and difficult to obtain, they are not commonly employed by the general population. With the advent of the Internet of Things (IoT), the Indoor Air Quality (IAQ) monitoring system has been simplified, and a number of studies have been conducted in order to monitor the IAQ using IoT. In this paper, we propose an improved IoT-based, low-cost IAQ monitoring system using Artificial Intelligence (AI) to provide recommendations. In our proposed system, the IoT sensors transmit data via Message Queuing Telemetry Transport (MQTT) protocol which can be visualised in real time on a user-friendly dashboard. Furthermore, the AI technique referred to as Long Short-Term Memory (LSTM) is applied to the collected CO2 data for the purpose of predicting future CO2 concentrations. Based on the predicted CO2 concentration, our system can compute CO(2 )steady state in advance with an error margin of 5.5%.
引用
收藏
页数:12
相关论文
共 36 条
[1]   Indoor Air Quality Analysis Using Deep Learning with Sensor Data [J].
Ahn, Jaehyun ;
Shin, Dongil ;
Kim, Kyuho ;
Yang, Jihoon .
SENSORS, 2017, 17 (11)
[2]   Associations of Cognitive Function Scores with Carbon Dioxide, Ventilation, and Volatile Organic Compound Exposures in Office Workers: A Controlled Exposure Study of Green and Conventional Office Environments [J].
Allen, Joseph G. ;
MacNaughton, Piers ;
Satish, Usha ;
Santanam, Suresh ;
Vallarino, Jose ;
Spengler, John D. .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2016, 124 (06) :805-812
[3]  
[Anonymous], 2007, 13779 EN CEN
[4]   CO2 based occupancy detection algorithm: Experimental analysis and validation for office and residential buildings [J].
Cali, Davide ;
Matthes, Peter ;
Huchtemann, Kristian ;
Streblow, Rita ;
Mueller, Dirk .
BUILDING AND ENVIRONMENT, 2015, 86 :39-49
[5]   HVAC system optimization with CO2 concentration control using genetic algorithms [J].
Congradac, Velimir ;
Kulic, Filip .
ENERGY AND BUILDINGS, 2009, 41 (05) :571-577
[6]   Indoor air quality levels in a University Hospital in the Eastern Province of Saudi Arabia [J].
El-Sharkawy, Mahmoud F. ;
Noweir, Mohamed E. H. .
JOURNAL OF FAMILY AND COMMUNITY MEDICINE, 2014, 21 (01) :39-47
[7]  
Erickson V. L., 2011, Proceedings 2011 10th International Conference on Information Processing in Sensor Networks (IPSN 2010), P258
[8]   Measurement of CO2 concentration for occupancy estimation in educational buildings with energy efficiency purposes [J].
Franco, Alessandro ;
Leccese, Francesco .
JOURNAL OF BUILDING ENGINEERING, 2020, 32
[9]   Novel second-degree solution to single zone mass-balance equation improves the use of build-up data in estimating ventilation rates in classrooms [J].
Hanninen, Otto .
JOURNAL OF CHEMICAL HEALTH & SAFETY, 2013, 20 (02) :14-19
[10]  
Hazlegreaves S., 2018, BRITAIN BECOMES INDO