Nonequilibrium Anion Detection in Solid-Contact Ion-Selective Electrodes

被引:0
作者
Gettler, Ryan C. [1 ]
Mehregan, Shima [2 ]
Koenig, Henry D. [2 ]
Kaess, Andie M. [1 ]
Young, Matthias J. [1 ,2 ,3 ]
机构
[1] Univ Missouri, Chem & Biomed Engn, Columbia, MO 65211 USA
[2] Univ Missouri, Dept Chem, Columbia, MO 65211 USA
[3] Univ Missouri, Mat Sci & Engn Inst, Columbia, MO 65211 USA
基金
美国国家科学基金会;
关键词
PULSED GALVANOSTATIC CONTROL; MOLECULARLY IMPRINTED POLYMERS; DETECTION LIMIT; MEMBRANE ELECTRODES; STATE; FERTILIZERS; VOLATILITY; MECHANISM; DIFFUSION; RESPONSES;
D O I
10.1021/acsomega.4c00131
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Low-cost and portable nitrate and phosphate sensors are needed to improve farming efficiency and reduce environmental and economic impact arising from the release of these nutrients into waterways. Ion selective electrodes (ISEs) could provide a convenient platform for detecting nitrate and phosphate, but existing ionophore-based nitrate and phosphate selective membrane layers used in ISEs are high cost, and ISEs using these membrane layers suffer from long equilibration time, reference potential drift, and poor selectivity. In this work, we demonstrate that constant current operation overcomes these shortcomings for ionophore-based anion-selective ISEs through a qualitatively different response mechanism arising from differences in ion mobility rather than differences in ion binding thermodynamics. We develop a theoretical treatment of phase boundary potential and ion diffusion that allows for quantitative prediction of electrode response under applied current. We also demonstrate that under pulsed current operation, we can create functional solid-contact ISEs using lower-cost molecularly imprinted polymers (MIPs). MIP-based nitrate sensors provide comparable selectivity against chloride to costlier ionophore-based sensors and exhibit >100,000 times higher selectivity against perchlorate. Likewise, MIP-based solid contact ion-selective electrode phosphate sensors operated under pulsed current provide competitive selectivity against chloride, nitrate, perchlorate, and carbonate anions. The theoretical treatment and conceptual demonstration of pulsed-current ISE operation we report will inform the development of new materials for membrane layers in ISEs based on differences in ion mobility and will allow for improved ISE sensor designs.
引用
收藏
页码:16443 / 16457
页数:15
相关论文
共 50 条
[31]   Pre-Polarized Hydrophobic Conducting Polymer Solid-Contact Ion Selective Electrodes with Improved Potential Reproducibility [J].
He, Ning ;
Papp, Soma ;
Lindfors, Tom ;
Hofler, Lajos ;
Latonen, Rose-Marie ;
Gyurcsanyi, Robert E. .
ANALYTICAL CHEMISTRY, 2017, 89 (04) :2598-2605
[32]   Comparison of different approaches to the description of the detection limit of ion-selective electrodes [J].
Jasielec, Jerzy J. ;
Sokalski, Tomasz ;
Filipek, Robert ;
Lewenstam, Andrzej .
ELECTROCHIMICA ACTA, 2010, 55 (22) :6836-6848
[33]   Physically Tailoring Ion Fluxes by Introducing Foamlike Structures into Polymeric Membranes of Solid Contact Ion-Selective Electrodes [J].
Cheong, Yi Heng ;
Lisak, Grzegorz .
ACS SENSORS, 2021, 6 (10) :3667-3676
[34]   Solid Contact Ion-Selective Electrodes with a Well-Controlled Co(II)/Co(III) Redox Buffer Layer [J].
Zou, Xu U. ;
Cheong, Jia H. ;
Taitt, Brandon J. ;
Buehlmann, Philippe .
ANALYTICAL CHEMISTRY, 2013, 85 (19) :9350-9355
[35]   Establishing Meaningful Limits of Detection for Ion-Selective Electrodes and Other Nonlinear Sensors [J].
Dillingham, Peter W. ;
Alsaedi, Basim S. O. ;
Granados-Focil, Sergio ;
Radu, Aleksandar ;
McGraw, Christina M. .
ACS SENSORS, 2020, 5 (01) :250-257
[36]   Hyphenated FT-IR-Attenuated Total Reflection and Electrochemical Impedance Spectroscopy Technique to Study the Water Uptake and Potential Stability of Polymeric Solid-Contact Ion-Selective Electrodes [J].
Lindfors, Tom ;
Hoefler, Lajos ;
Jagerszki, Gyula ;
Gyurcsanyi, Robert E. .
ANALYTICAL CHEMISTRY, 2011, 83 (12) :4902-4908
[37]   Improved Solid-Contact Nitrate Ion Selective Electrodes Based on Multi-Walled Carbon Nanotubes (MWCNTs) as an Ion-to-Electron Transducer [J].
Hassan, Saad S. M. ;
Eldin, Ahmed Galal ;
Amr, Abd El-Galil E. ;
Al-Omar, Mohamed A. ;
Kamel, Ayman H. ;
Khalifa, Nagy M. .
SENSORS, 2019, 19 (18)
[38]   Rational design of all-solid-state ion-selective electrodes and reference electrodes [J].
Hu, Jinbo ;
Stein, Andreas ;
Buehlmann, Philippe .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 76 :102-114
[39]   Influence of phosphate buffer and proteins on the potentiometric response of a polymeric membrane-based solid-contact Pb(II) ion-selective electrode [J].
Joon, Narender Kumar ;
He, Ning ;
Wagner, Michal ;
Cardenas, Marite ;
Bobacka, Johan ;
Lisak, Grzegorz .
ELECTROCHIMICA ACTA, 2017, 252 :490-497
[40]   Design of Solid-Contact Ion-Selective Electrode with Graphene Transducer Layer for the Determination of Flavoxate Hydrochloride in Dosage Form and in Spiked Human Plasma [J].
Mahmoud, Amr M. ;
Ragab, Mona T. ;
Ramadan, Nesrin K. ;
El-Ragehy, Nariman A. ;
El-Zeany, Badr A. .
ELECTROANALYSIS, 2020, 32 (12) :2803-2811