Development of an innovative optical sensor to detect extremely low levels of chromium in real samples using colorimetric methods

被引:2
作者
Darwish, Eman R. [1 ]
Alshehri, Reem F. [2 ]
Amin, Alaa S. [3 ]
Aish, Mai [1 ]
机构
[1] Port Said Univ, Fac Sci, Chem Dept, Port Said, Egypt
[2] Taibah Univ, Coll Sci, Chem Dept, Yanbu, Saudi Arabia
[3] Benha Univ, Fac Sci, Chem Dept, Banha, Egypt
来源
ENVIRONMENTAL SCIENCE-ADVANCES | 2024年 / 3卷 / 02期
关键词
SOLID-PHASE EXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; HEXAVALENT CHROMIUM; SPECIATION ANALYSIS; WATER SAMPLES; MEMBRANE; CR(VI); IONS; MICROEXTRACTION; NANOPARTICLES;
D O I
10.1039/d3va00257h
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The investigation focused on a methodology for concentrating and analyzing Cr(vi) in aqueous samples. This objective was accomplished through the creation of a cellulose triacetate (CTA) matrix-based membrane optode. This optode was constructed by physically integrating a specific chromophore, 1,3-benzenediamine,N,N '-bis(2-furanylmethylene) (BDBFM), known for its selectivity towards Cr(vi), alongside the plasticizer dioctylphthalate (DOP). The effectiveness of integrating Aliquat 336, an anion exchanger, was evaluated in the process of immobilizing both BDBFM and the Cr(vi)-BDBFM complex within the optode matrix. The progressive intensification of the violet color observed on the optodes, directly correlating with the amount of loaded Cr(vi), highlights the potential of this method for colorimetric screening of Cr(vi) in aqueous samples. The developed optode was also employed for the determination of the total chromium content by converting Cr(iii) to Cr(vi) via oxidation using 0.1 M hydrogen peroxide. The concentration of Cr(iii) can be quantified by subtracting the amount of Cr(vi) from the total chromium content. This optode enabled the quantitative detection of Cr(vi), even at levels as low as 2.85 ng mL-1. The suggested sensor displayed a low detection limit, fast response time, cost effectiveness, ease of preparation and also remarkable selectivity regarding some anions and cations. Regeneration of the optode can be easily accomplished by employing 0.05 M HNO3, while demonstrating remarkable reproducibility and reversibility in its response, with a relative standard deviation (RSD) below 1.9. The suggested method was effectively utilized to measure chromium levels in a diverse range of samples, such as food, water, and environmental, and biological samples. The investigation focused on a methodology for concentrating and analyzing Cr(vi) in aqueous samples.
引用
收藏
页码:274 / 289
页数:16
相关论文
共 79 条
  • [1] Optical fibre Al(III) sensor based on solid surface fluorescence measurement
    Ahmad, M
    Narayanaswamy, R
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 81 (2-3) : 259 - 266
  • [2] A new triazene-1-oxide derivative, immobilized on the triacetyl cellulose membrane as an optical Ni2+ sensor
    Alizadeh, Kamal
    Rezaei, Behrooz
    Khazaeli, Elaheh
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 193 : 267 - 272
  • [3] Heavy metals contaminating the environment of a progressive supranuclear palsy cluster induce tau accumulation and cell death in cultured neurons
    Alquezar, Carolina
    Felix, Jessica B.
    McCandlish, Elizabeth
    Buckley, Brian T.
    Caparros-Lefebvre, Dominique
    Karch, Celeste M.
    Golbe, Lawrence I.
    Kao, Aimee W.
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [4] Amin A. S., 2021, Iran. J. Anal. Chem, V8, P65
  • [5] A novel sensor for the selective monitoring of trace ytterbium ions using an agarose-based optical membrane
    Amin, Alaa S.
    El-Feky, Hesham H.
    Hassan, Nader
    [J]. RSC ADVANCES, 2022, 12 (41) : 26620 - 26629
  • [6] Utility of 5-(2′,4′-dimethylphenylazo)-6-hydroxy-pyrimidine-2,4-dione in PVC membrane for a novel green optical chemical sensor to detect zinc ion in environmental samples
    Amin, Alaa S.
    El-Bahy, Salah
    El-Feky, Hesham H.
    [J]. ANALYTICAL BIOCHEMISTRY, 2022, 643
  • [7] Application of a triacetylcellulose membrane with immobilizated of 5-(2′,4′-dimethylphenylazo)-6-hydroxypyrimidine-2,4-dione for mercury determination in real samples
    Amin, Alaa S.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 1342 - 1347
  • [8] Amin AS., 2018, EURASIAN J ANAL CHEM, V13, P1, DOI [10.29333/ejac/94447, DOI 10.29333/EJAC/94447]
  • [9] [Anonymous], 1978, SPECTROCHEM ACTA, V33B, P241, DOI [DOI 10.1016/0584-8547(78)80044-5, 10.1016/0584-8547(78)80044-5]
  • [10] Britton H., 1952, HYDROGEN IONS