Clinical comparison of three SARS-CoV-2 nucleic acid amplification tests for routine diagnostic testing

被引:0
|
作者
Garmatiuk, Tetiana [1 ,4 ]
Graenitz-Trisko, Christine [1 ]
Sochor-Geischlaeger, Charlotte [1 ]
Polsterer, Theresa [1 ]
Caselotto, Francesca [1 ]
Willitsch, Lukas [1 ]
Reinhardt, Birgit [2 ]
Huf, Wolfgang [3 ]
机构
[1] Hietzing Hosp, Dept Lab Med, Wolkersbergenstr 1, A-1130 Vienna, Austria
[2] Abbott GmbH, Max Planck Ring 2, D-65205 Wiesbaden, Germany
[3] Karl Landsteiner Inst Clin Risk Management, Wolkersbergenstr 1, A-1130 Vienna, Austria
[4] Inst Labormedizin, Klin Hietzing, Austria, Wolkersbergenstr 1, A-1130 Vienna, Austria
关键词
SARS-CoV-2; Real-time PCR; Alinity m; Respiratory viruses; PERFORMANCE;
D O I
10.1016/j.heliyon.2023.e22112
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Cycle threshold (Ct) values from SARS-CoV-2 nucleic acid amplification tests have been used to estimate viral load for treatment decisions. Additionally, there is a need for high throughput testing, consolidating a variety of assays on one random-access analyzer.Objectives: In this study, the clinical performance of the Alinity m SARS-CoV-2, RealTime SARSCoV-2, and GeneXpert Xpress SARS-CoV-2/Flu/RSV assays was assessed.Methods: Alinity precision and detection rates were evaluated using a dilution series of the Alinity m SARS-CoV-2 positive control. In a retrospective study, 7 remnant external quality assessment (EQA) specimens and 200 remnant nasopharyngeal swab specimens (100 positive and 100 negative) were tested in the three assays.Results: Alinity had 100 % detection rate at 50 copies/mL and high reproducibility (Ct value coefficient of variation <= 3.1 %). All three assays correctly detected positive and negative EQA samples with comparable Ct values (max difference 2.38) and high linearity. In patient samples, positive percent agreement was 95 % (95 % CI 89-98 %) and negative percent agreement was 100 % (95 % CI 96-100 %) for Alinity, compared to the other two assays. Four specimens detected on Alinity m but not RealTime or Xpert had Ct values above 40. Assay results were highly correlated (r >= 0.94). Ct values (after addition of 10 unread cycles to the reported Ct of RealTime) were comparable across the three assays.Conclusions: Alinity m had high precision and accuracy and Ct values comparable to those of the RealTime and Xpert assays. The assays could be used interchangeably, with no need for adjustment of patient management decisions based on Ct values from each assay.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Clinical Utility of SARS-CoV-2 Rapid Antigen Test in the Emergency Department
    Lee, Dong-hyun
    Kim, Jinyeong
    Ryu, Soorack
    Kim, Jieun
    Han, Eunhee
    Choi, Hyuk Joong
    CLINICAL LABORATORY, 2023, 69 (11) : 2323 - 2332
  • [22] Saliva as a diagnostic specimen for SARS-CoV-2 detection: A scoping review
    Wang, Yifei
    Upadhyay, Akshaya
    Pillai, Sangeeth
    Khayambashi, Parisa
    Tran, Simon D.
    ORAL DISEASES, 2022, 28 : 2362 - 2390
  • [23] Testing for SARS-CoV-2: lessons learned and current use cases
    Theel, Elitza S.
    Kirby, James E.
    Pollock, Nira R.
    CLINICAL MICROBIOLOGY REVIEWS, 2024, 37 (02) : e0007223
  • [24] SARS-CoV-2 Antigen Testing Intervals: Twice or Thrice a Week?
    Lau, Chin Shern
    Aw, Tar-Choon
    DIAGNOSTICS, 2022, 12 (05)
  • [25] Prevalence of a Single-Nucleotide Variant of SARS-CoV-2 in Korea and Its Impact on the Diagnostic Sensitivity of the Xpert Xpress SARS-CoV-2 Assay
    Hong, Ki Ho
    In, Ji Won
    Lee, Jaehyeon
    Kim, So Yeon
    Lee, Kyoung Ah
    Kim, Seunghyun
    An, Yeoungim
    Lee, Donggeun
    Sung, Heungsup
    Kim, Jae-Seok
    Lee, Hyukmin
    ANNALS OF LABORATORY MEDICINE, 2022, 42 (01) : 96 - +
  • [26] Meta-analysis of the diagnostic performance characteristics of three commercial and one in-house nucleic acid amplification tests for malaria screening
    Altangerel, Enkhtsetseg
    Frickmann, Hagen
    JOURNAL OF LABORATORY MEDICINE, 2020, 44 (01) : 47 - 53
  • [27] Diagnostic Accuracy of SARS-CoV-2 Antigen Tests for Community Transmission Screening: A Systematic Review and Meta-Analysis
    Chen, Cheng-Chieh
    Lu, Shou-Cheng
    Bai, Chyi-Huey
    Wang, Pei-Yu
    Lee, Kang-Yun
    Wang, Yuan-Hung
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (21)
  • [28] Providing a laboratory diagnostic service for pandemic SARS-CoV-2 in a developing country
    Sam, I-Ching
    Chong, Jennifer
    Kamarudin, Rozainah
    Jafar, Faizatul Lela
    Lee, Lu Mei
    Bador, Maria Kahar
    Chew, Yee Yean
    Tan, Maw Pin
    Chan, Yoke Fun
    TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2020, 114 (08) : 553 - 555
  • [29] Mutations in Animal SARS-CoV-2 Induce Mismatches with the Diagnostic PCR Assays
    Elaswad, Ahmed
    Fawzy, Mohamed
    PATHOGENS, 2021, 10 (03):
  • [30] Practical challenges to the clinical implementation of saliva for SARS-CoV-2 detection
    Matic, Nancy
    Stefanovic, Aleksandra
    Leung, Victor
    Lawson, Tanya
    Ritchie, Gordon
    Li, Lynne
    Champagne, Sylvie
    Romney, Marc G.
    Lowe, Christopher F.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2021, 40 (02) : 447 - 450