Automated and semi-automated 3D echocardiographic software for aortic annulus sizing in transcatheter aortic valve implantation helps bridge the gap between expert and novice operators

被引:0
|
作者
Massie, Charles [1 ]
Parent, Martine [1 ]
Berthelot-Richer, Maxime [1 ,2 ]
Kouz, Remi [1 ]
Palisaitis, Donald [1 ]
Le, Viet [1 ]
Poulin, Frederic [1 ]
机构
[1] Hop Sacre Coeur Montreal, 5400 Boul Gouin O, Montreal, PQ H4J 1C5, Canada
[2] Hotel Dieu Quebec, Quebec City, PQ, Canada
来源
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING | 2023年 / 39卷 / 09期
关键词
Three-dimensional echocardiography; TAVI; Aortic annulus; Automated; Novice; COMPUTED-TOMOGRAPHY; REPLACEMENT; ACCURACY;
D O I
10.1007/s10554-023-02885-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
3D-transesophageal echocardiography (3D-TEE) is an alternative to multidetector row computed tomography (MDCT) for aortic annulus (AoA) sizing in preparation for Transcatheter aortic valve implantation (TAVI). We aim to evaluate how the fully automated (auto) and semi-automated (SA) TEE methods perform compared to conventional manual TEE method and the gold standard MDCT for annulus sizing both in expert and novice operators. In this prospective cohort study, eighty-nine patients with severe aortic stenosis underwent multimodality imaging with 3D-TEE and MDCT. Annular measurements were collected by expert echocardiographers using 3D auto, SA and manual methods and compared to MDCT. A novice in the field of echocardiography retrospectively measured the AoA for all patients using the same methods. TEE measurements, independently of the method used, had good to very good agreement to MDCT. They significantly underestimated aortic annular area and circumference vs. MDCT with the auto method underestimating it the most and the manual method the least (6.5% and 1.3% respectively for area and circumference). For experts, the manual TEE method offered the least systematic bias while the SA method had narrower limits of agreement (LOA). For the novice operator, SA method provided the least bias and narrower LOA vs. MDCT. There is good agreement between novice and experts for all 3 TEE methods but better agreement with auto and SA methods as opposed to manual one. Our study supports the use of 3D-TEE as a complementary method to MDCT for aortic annular sizing. The newer auto and SA software, that requires minimal operator intervention, is an easy to use, reliable and reproducible tool for aortic annulus sizing for experienced operators, and especially less experienced ones.
引用
收藏
页码:1707 / 1717
页数:11
相关论文
共 14 条
  • [1] Automated and semi-automated 3D echocardiographic software for aortic annulus sizing in transcatheter aortic valve implantation helps bridge the gap between expert and novice operators
    Charles Massie
    Martine Parent
    Maxime Berthelot-Richer
    Rémi Kouz
    Donald Palisaitis
    Viet Le
    Frédéric Poulin
    The International Journal of Cardiovascular Imaging, 2023, 39 : 1707 - 1717
  • [2] Automatic 3D aortic annulus sizing by computed tomography in the planning of transcatheter aortic valve implantation
    Queiros, Sandro
    Dubois, Christophe
    Morais, Pedro
    Adriaenssens, Tom
    Fonseca, Jaime C.
    Vilaca, Joao L.
    D'hooge, Jan
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2017, 11 (01) : 25 - 32
  • [3] Accuracy and reproducibility of aortic annular measurements obtained from echocardiographic 3D manual and semi-automated software analyses in patients referred for transcatheter aortic valve implantation: implication for prosthesis size selection
    Stella, Stefano
    Italia, Leonardo
    Geremia, Giulia
    Rosa, Isabella
    Ancona, Francesco
    Marini, Claudia
    Capogrosso, Cristina
    Giglio, Manuela
    Montorfano, Matteo
    Latib, Azeem
    Margonato, Alberto
    Colombo, Antonio
    Agricola, Eustachio
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 (01) : 45 - 55
  • [4] Semi-automated versus Manual Aortic Annulus Analysis for Planning of Transcatheter Aortic Valve Replacement (TAVR/TAVI)
    Lou, Junyang
    Obuchowski, Nancy A.
    Krishnaswamy, Amar
    Popovic, Zoran
    Flamm, Scott D.
    Bolen, Michael
    Desai, Milind
    Kapadia, Samir R.
    Svensson, Lars G.
    Tuzcu, E. M.
    Schoenhagen, Paul
    CIRCULATION, 2013, 128 (22)
  • [5] 3D echocardiographic analysis of aortic annulus for transcatheter aortic valve replacement using novel aortic valve quantification software: Comparison with computed tomography
    Mediratta, Anuj
    Addetia, Karima
    Medvedofsky, Diego
    Schneider, Robert J.
    Kruse, Eric
    Shah, Atman P.
    Nathan, Sandeep
    Paul, Jonathan D.
    Blair, John E.
    Ota, Takeyoshi
    Balkhy, Husam H.
    Patel, Amit R.
    Mor-Avi, Victor
    Lang, Roberto M.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (05): : 690 - 699
  • [6] Validation of 3D-reconstructed computed tomography images using OsiriX® software for pre-transcatheter aortic valve implantation aortic annulus sizing
    Gumsheimer, Marlena
    Stortecky, Stefan
    Gahl, Brigitta
    Langhammer, Bettina
    Carrel, Thierry
    Buellesfeld, Lutz
    Huber, Christoph
    Most, Henriette
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 25 (02) : 198 - 205
  • [7] Intraoperative 2D and 3D transoesophageal echocardiographic predictors of aortic regurgitation after transcatheter aortic valve implantation
    Gripari, Paola
    Ewe, See Hooi
    Fusini, Laura
    Muratori, Manuela
    Ng, Arnold C. T.
    Cefalu, Claudia
    Delgado, Victoria
    Schalij, Martin J.
    Bax, Jeroen J.
    Marsan, Nina Ajmone
    Tamborini, Gloria
    Pepi, Mauro
    HEART, 2012, 98 (16) : 1229 - 1236
  • [8] Pre- TAVI aortic annulus sizing: comparison between manual and semi- automated new generation software measurements in operators with different experience
    Annoni, Andrea Daniele
    Mancini, Maria Elisabetta
    Carlicchi, Eleonora
    Belmonte, Marta
    Formenti, Alberto
    Mushtaq, Saima
    Marchetti, Francesca
    Cilia, Francesco
    Baggiano, Andrea
    Fusini, Laura
    Bonomi, Alice
    Gennari, Marco
    Montorsi, Piero
    Pepi, Mauro
    Pontone, Gianluca
    BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1149):
  • [9] Influence of the Quantity of Aortic Valve Calcium on the Agreement Between Automated 3-Dimensional Transesophageal Echocardiography and Multidetector Row Computed Tomography for Aortic Annulus Sizing
    Podlesnikar, Tomaz
    Prihadi, Edgard A.
    van Rosendael, Philippe J.
    Vollema, E. Mara
    van der Kley, Frank
    de Weger, Arend
    Marsan, Nina Ajmone
    Naji, Franjo
    Fras, Zlatko
    Bax, Jeroen J.
    Delgado, Victoria
    AMERICAN JOURNAL OF CARDIOLOGY, 2018, 121 (01): : 86 - 93
  • [10] Feasibility, Accuracy, and Reproducibility of Aortic Annular and Root Sizing for Transcatheter Aortic Valve Replacement Using Novel Automated Three-Dimensional Echocardiographic Software: Comparison with Multi-Detector Row Computed Tomography
    Prihadi, Edgard A.
    van Rosendael, Philippe J.
    Vollema, E. Mara
    Bax, Jeroen J.
    Delgado, Victoria
    Marsan, Nina Ajmone
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2018, 31 (04) : 505 - +