The Test-Retest Reproducibility, Standard Error Measurement, and Smallest Real Difference of Dynamic Balance Tests in Chronic Stroke Survivors

被引:0
作者
Lee, Kyeongbong [1 ]
Lee, GyuChang [2 ]
机构
[1] Kangwon Natl Univ, Dept Phys Therapy, Samcheok 25949, South Korea
[2] Kyungnam Univ, Dept Phys Therapy, Chang Won 51767, South Korea
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 11期
关键词
test-retest reproducibility; dynamic balance; stroke; STEP TEST-SCORES; STATISTICAL-METHODS; RELIABILITY; SENSITIVITY; AGREEMENT; VALIDITY; GRIP;
D O I
10.3390/app13116358
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Background: A dynamic balance assessment of stroke patients is a very important factor in their rehabilitation process. The aim of this study was to investigate the test-retest reproducibility and smallest real differences in the dynamic balance tests of chronic stroke survivors. Methods: This was a methodological study that fifty-three chronic stroke survivors participated in. Dynamic balance tests were performed using the figure of eight walk test, four square step test, and step test. These tests and measurements were performed twice with 1-week intervals and intra-class correlation coefficients (ICC) were used to investigate their test-retest reliability. To determine the size of the measurement error, the standard error of measurement (SEM) and smallest real difference (SRD) were used. The SEM was used to compare the test-retest reproducibility. Results: The test-retest reliability of the figure of eight walk test, four square step test, and step test was confirmed to be high, with an ICC = 0.93 similar to 0.99. The SEMs were 2.21 and 2.25 for the figure of eight walk test and four-square step test, respectively. As for the step test (paretic and non-paretic side), the SEMs were 0.68 and 0.70, respectively, which were <10% of the average score. The SRDs of the figure of eight walk test, four square step test, and step test (paretic and non-paretic side) were 6.10, 6.21, and 1.87 and 1.93, respectively. This showed a reliability of <20% of the highest score. The SRDs (%) of the figure of eight walk test, four square step test, and step test (paretic and non-paretic sides) were 28.9%, 21.9%, and 27.32% and 24.43%, respectively. The SEM for all the tests was <30% and the level of measurement error was acceptable. The ICCs of the test-retest reliability of the figure of eight walk test, four square step test, and step test were identified as high, and the test-retest reproducibility was verified by the low values of the SEM and SRD. Conclusions: The figure of eight walk test, four square step test, and step test might be useful tools for clinicians to examine the changes in dynamic balance over time in the rehabilitation of chronic stroke survivors.
引用
收藏
页数:8
相关论文
共 25 条
  • [1] [Anonymous], Stroke rehabilitation information
  • [2] Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine
    Atkinson, G
    Nevill, AM
    [J]. SPORTS MEDICINE, 1998, 26 (04) : 217 - 238
  • [3] Smallest real difference, a link between reproducibility and responsiveness
    Beckerman, H
    Roebroeck, ME
    Lankhorst, GJ
    Becher, JG
    Bezemer, PD
    Verbeek, ALM
    [J]. QUALITY OF LIFE RESEARCH, 2001, 10 (07) : 571 - 578
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] STATISTICAL-METHODS FOR ASSESSING OBSERVER VARIABILITY IN CLINICAL MEASURES
    BRENNAN, P
    SILMAN, A
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 1992, 304 (6840): : 1491 - 1494
  • [6] The test-retest reliability of 2 mobility performance tests in patients with chronic stroke
    Chen, Hui-Mei
    Hsieh, Ching-Lin
    Lo, Sing Kai
    Liaw, Lih-Jiun
    Chen, Shih-Ming
    Lin, Jau-Hong
    [J]. NEUROREHABILITATION AND NEURAL REPAIR, 2007, 21 (04) : 347 - 352
  • [7] When to use agreement versus reliability measures
    de Vet, Henrica C. W.
    Terwee, Caroline B.
    Knol, Dirk L.
    Bouter, Lex M.
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 2006, 59 (10) : 1033 - 1039
  • [8] A clinical test of stepping and change of direction to identify multiple falling older adults
    Dite, W
    Temple, VA
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (11): : 1566 - 1571
  • [9] Reliability and Concurrent Validity of Four Square Step Test Scores in Subjects With Chronic Stroke: A Pilot Study
    Goh, Esther Y.
    Chua, Salan Y.
    Hong, Sze-Jia
    Ng, Shamay S.
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2013, 94 (07): : 1306 - 1311
  • [10] Reliability of a measurement of neck flexor muscle endurance
    Harris, KD
    Heer, DM
    Roy, TC
    Santos, DM
    Whitman, JM
    Wainner, RS
    [J]. PHYSICAL THERAPY, 2005, 85 (12): : 1349 - 1355