A Wireless Low-Power Single-Unit Wearable System for Continuous Early Warning Score Calculation

被引:2
|
作者
Bellier, Pierre [1 ]
Wallant, Dorothee Coppieters't [1 ,2 ]
van den Bongarth, Henri [3 ]
Bijnens, Wouter
Aarts, Jos
Vandenryt, Thijs [4 ]
Thoelen, Ronald [4 ]
Duflot, Patrick [5 ]
Dupont, Francois [1 ]
Redoute, Jean-Michel [1 ]
机构
[1] Univ Liege, Microsys Lab, B-4000 Liege, Belgium
[2] BEA Sensors Europe, B-4000 Liege, Belgium
[3] Maastricht Univ, Res Engn, NL-6211 LK Maastricht, Netherlands
[4] Hasselt Univ, Inst Mat Res, B-3590 Diepenbeek, Belgium
[5] CHU Liege, B-4000 Liege, Belgium
关键词
Electrocardiography; Sensors; Temperature measurement; Monitoring; Bioimpedance; Biomedical monitoring; Temperature sensors; Continuous vitals monitoring; medical device; near real-time; sensor signal processing; wearable electronics; wireless; GREEN; LIGHT; TIME;
D O I
10.1109/JSEN.2023.3267146
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, we present a new device to monitor the five main vital parameters of hospitalized patients: heart rate (HR), respiratory rate (RR), blood oxygen saturation, blood pressure (BP), and temperature. The device consists of one single unit placed on the chest with two electrodes connected to the patient. The device continuously acquires the electrocardiogram (ECG), three-wavelength photoplethysmogram (PPG), bioimpedance, body temperature, and three-axis acceleration. These raw data are securely sent via a Wi-Fi access point to a local server where algorithms are running to calculate the five vital parameters, combined with the level of activity and the posture. Alarms, live stream, and a real-time estimation of the early warning score (EWS) used to assess the instantaneous state of a patient are available to nurses to react quickly and adequately if needed. Due to its small form factor and weight, the device is worn unobtrusively by the patient who can move without being restrained by wires; a small battery ensures an autonomy of a few days. In this article, the firmware and hardware architectures are detailed comprising the list of the sensors, the main chips used, and the casing. The relationships between what the sensors measure and the vital parameters of interest are discussed.
引用
收藏
页码:12171 / 12180
页数:10
相关论文
共 22 条
  • [21] A 2.16-μW Low-Power Continuous-Time Delta-Sigma Modulator With Improved-Linearity Gm for Wearable ECG Application
    Kim, Jaedo
    Duan, Quanzhen
    Choi, Jihun
    Song, Chiho
    Roh, Jeongjin
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2022, 69 (11) : 4223 - 4227
  • [22] A Low-Power Single-Path Bio-Impedance Measurement System Using an Analog-to-Digital Converter for I/Q Demodulation
    Rezaee-Dehsorkh, Hamidreza
    Ravanshad, Nassim
    Shamsaki, Ali
    Fakour, Maryam Rouhbakhsh
    Aliparast, Peiman