One center experience with a personalized frozen-thawed embryo transfer in patients with recurrent implantation failure

被引:4
作者
Edimiris, Philippos [1 ]
Doehmen, Cornelius [1 ,2 ]
Baston-Buest, Dunja Maria [1 ]
Kruessel, Jan-Steffen [1 ]
Bielfeld, Alexandra Petra [1 ]
机构
[1] Univ Duesseldorf, Med Ctr, Dept OB GYN & REI UniKiD, Moorenstr 5, D-40225 Dusseldorf, Germany
[2] Kinderwunschzentrum Niederrhein, Madrider Str 6, D-41069 Monchengladbach, Germany
关键词
Recurrent implantation failure; Endometrial receptivity analysis; Window of implantation; Programmed frozen-thawed embryo transfer; LUTEAL-PHASE SUPPORT; ENDOMETRIAL RECEPTIVITY; LIVE BIRTH; PROGESTERONE LEVELS; WINDOW; DURATION; WOMEN; TRIAL; CYCLE; TIME;
D O I
10.1007/s10815-023-02835-7
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
PurposeDisplaced endometrial receptivity has been discussed as a possible cause of recurrent implantation failure in patients undergoing assisted reproductive technology. The aim of this study was to document our experience with the endometrial receptivity analysis in patients with recurrent implantation failure.MethodsThis retrospective cohort study, conducted at the Fertility Centre of the University Hospital, Duesseldorf Germany, presents the results of the endometrial receptivity analysis in 67 patients with recurrent implantation failure and compares the clinical outcome between these 67 patients who underwent a personalized frozen-thawed embryo transfer guided by the results of the endometrial receptivity analysis and 32 patients with recurrent implantation failure who performed a standardized frozen-thawed embryo transfer.ResultsThe data analysis revealed a displaced endometrial receptivity in 73% (49/67) of all tested patients. Out of these patients, 24% (12/49) were early receptive, 74% (36/49) were pre-receptive, and 2% (1/49) were post-receptive. Comparison of pregnancy rate, clinical pregnancy rate, and live-birth rate between personalized (49%, 39%, 27%, respectively) and standardized embryo transfer (44%, 31%, 19%, respectively) reveals no statistically significant difference. In both groups, patients had an average of four unsuccessful embryo transfers.ConclusionIn this cohort of patients with recurrent implantation failure, the endometrial receptivity analysis showed a high incidence of displaced endometrial receptivity. However, a personalized embryo transfer did not increase reproductive outcome. Displaced endometrial receptivity might not be the main cause for recurrent implantation failure in this cohort.
引用
收藏
页码:1639 / 1647
页数:9
相关论文
共 40 条
  • [1] Endometrial receptivity markers, the journey to successful embryo implantation
    Achache, Hanna
    Revel, Ariel
    [J]. HUMAN REPRODUCTION UPDATE, 2006, 12 (06) : 731 - 746
  • [2] Increasing vaginal progesterone gel supplementation after frozen-thawed embryo transfer significantly increases the delivery rate
    Alsbjerg, Birgit
    Polyzos, Nikolaos P.
    Elbaek, Helle Olesen
    Povlsen, Betina Boel
    Andersen, Claus Yding
    Humaidan, Peter
    [J]. REPRODUCTIVE BIOMEDICINE ONLINE, 2013, 26 (02) : 133 - 137
  • [3] Individualised luteal phase support in artificially prepared frozen embryo transfer cycles based on serum progesterone levels: a prospective cohort study
    Alvarez, Manuel
    Gaggiotti-Marre, Sofia
    Martinez, Francisca
    Coll, Lluc
    Garcia, Sandra
    Gonzalez-Foruria, Inaki
    Rodriguez, Ignacio
    Parriego, Monica
    Polyzos, Nikolaos P.
    Coroleu, Buenaventura
    [J]. HUMAN REPRODUCTION, 2021, 36 (06) : 1552 - 1560
  • [4] Does the endometrial receptivity array really provide personalized embryo transfer?
    Bassil, Rawad
    Casper, Robert
    Samara, Nivin
    Hsieh, Tzu-Bou
    Barzilay, Eran
    Orvieto, Raoul
    Haas, Jigal
    [J]. JOURNAL OF ASSISTED REPRODUCTION AND GENETICS, 2018, 35 (07) : 1301 - 1305
  • [5] Endometrial Receptivity Analysis (ERA) test: an unproven technology
    Ben Rafael, Zion
    [J]. HUMAN REPRODUCTION OPEN, 2021, 2021 (02)
  • [6] Recurrent implantation failure: definition and management
    Coughlan, C.
    Ledger, W.
    Wang, Q.
    Liu, Fenghua
    Demirol, Aygul
    Gurgan, Timur
    Cutting, R.
    Ong, K.
    Sallam, H.
    Li, T. C.
    [J]. REPRODUCTIVE BIOMEDICINE ONLINE, 2014, 28 (01) : 14 - 38
  • [7] Evaluation of the endometrial receptivity assay and the preimplantation genetic test for aneuploidy in overcoming recurrent implantation failure
    Cozzolino, Mauro
    Diaz-Gimeno, Patricia
    Pellicer, Antonio
    Garrido, Nicolas
    [J]. JOURNAL OF ASSISTED REPRODUCTION AND GENETICS, 2020, 37 (12) : 2989 - 2997
  • [8] Implantation Failures and Miscarriages in Frozen Embryo Transfers Timed in Hormone Replacement Cycles (HRT): A Narrative Review
    de Ziegler, Dominique
    Pirtea, Paul
    Ayoubi, Jean Marc
    [J]. LIFE-BASEL, 2021, 11 (12):
  • [9] The accuracy and reproducibility of the endometrial receptivity array is superior to histology as a diagnostic method for endometrial receptivity
    Diaz-Gimeno, Patricia
    Ruiz-Alonso, Maria
    Blesa, David
    Bosch, Nuria
    Martinez-Conejero, Jose A.
    Alama, Pilar
    Garrido, Nicolas
    Pellicer, Antonio
    Simon, Carlos
    [J]. FERTILITY AND STERILITY, 2013, 99 (02) : 508 - 517
  • [10] A genomic diagnostic tool for human endometrial receptivity based on the transcriptomic signature
    Diaz-Gimeno, Patricia
    Horcajadas, Jose A.
    Martinez-Conejero, Jose A.
    Esteban, Francisco J.
    Alama, Pilar
    Pellicer, Antonio
    Simon, Carlos
    [J]. FERTILITY AND STERILITY, 2011, 95 (01) : 50 - U611