Comparison of Robot-Assisted Percutaneous Cannulated Screws Versus Open Reduction and Internal Fixation in Calcaneal Fractures

被引:13
作者
Wang, Jing [1 ]
Han, Wei [1 ]
Su, Yonggang [1 ]
Wang, Junqiang [1 ]
Jiang, Xieyuan [1 ]
机构
[1] Beijing Jishuitan Hosp, Dept Orthopaed Trauma, Beijing, Peoples R China
关键词
Calcaneal Fracture; Open Reduction and Internal Fixation; Percutaneous; TiRobot;
D O I
10.1111/os.13650
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ObjectiveAccurate placement of the screws is challenging in percutaneous cannulated screw fixation of calcaneal fractures, and robot-assisted (RA) surgery enhances the accuracy. We investigated the outcome of percutaneous cannulated screw fixation of Sander's type II and III calcaneal fractures. MethodsThis retrospective study analyzed clinical data of 26 patients with fresh closed calcaneal fractures (28 fractures) who were admitted to our center from January 2022 to July 2022. All fractures were divided into the RA group and the open reduction and internal fixation (ORIF) group according to the surgeries performed. RA surgery was performed by closed reduction or open reduction combined with a tarsal sinus approach. Age, sex, operation time, preoperative waiting time, length of postoperative hospital stay, wound complications, and American Orthopaedic Foot and Ankle Society Ankle Hindfoot Scale (AOFAS) at 3 months postoperatively were compared. Preoperative and postoperative radiographic parameters (calcaneal length, width, height, Bohler angle, and fixation rate of the sustentaculum tali) were documented. The chi-square test, one-way analysis of variance, and Wilcoxon test were used for the comparison of categorical, normally distributed, and nonnormally distributed continuous variables, respectively. ResultsThe calcaneal width, height, and Bohler angle were significantly corrected postoperatively in both groups. The postoperative calcaneal lengths in both groups were also corrected. However, no significant difference was found. No significant differences in calcaneal length, width, height, and Bohler angle were observed between the two groups. The operation time (p < 0.001), preoperative waiting time (p < 0.001), and length of postoperative hospital stay (p = 0.003) in the RA surgery group were significantly shorter than those in the ORIF group. The fixation rate of the sustentaculum tali (p < 0.001) in the RA surgery group was significantly superior to that in the ORIF group. All wound complications occurred in the ORIF group. All fractures healed within 3 months. The AOFAS scores at 3 months postoperatively were not significantly different. ConclusionRA percutaneous screw fixation of the calcaneal fracture is a safe, effective, rapid, and minimally invasive surgical option for surgeons.
引用
收藏
页码:724 / 730
页数:7
相关论文
共 21 条
[1]  
Abdelgaid Sherif Mohamed, 2012, Foot Ankle Surg, V18, P164, DOI 10.1016/j.fas.2011.07.005
[2]  
Allegra Paul R, 2020, Foot Ankle Orthop, V5, p2473011420927334, DOI 10.1177/2473011420927334
[3]   Early Minimally Invasive Percutaneous Fixation of Displaced Intra-Articular Calcaneal Fractures With a Percutaneous Angle Stable Device [J].
Battaglia, Alberto ;
Catania, Pompeo ;
Gumina, Stefano ;
Carbone, Stefano .
JOURNAL OF FOOT & ANKLE SURGERY, 2015, 54 (01) :51-56
[4]   Percutaneous Reduction and Fixation of Displaced Intra-Articular Calcaneus Fractures [J].
DeWall, Matthew ;
Henderson, Christopher E. ;
McKinley, Todd O. ;
Phelps, Thomas ;
Dolan, Lori ;
Marsh, J. L. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (08) :466-472
[5]   Fixation Methods for Calcaneus Fractures: A Systematic Review of Biomechanical Studies Using Cadaver Specimens [J].
Dingemans, Siem A. ;
Sintenie, Floris W. ;
de Jong, Vincent M. ;
Luitse, Jan S. K. ;
Schepers, Tim .
JOURNAL OF FOOT & ANKLE SURGERY, 2018, 57 (01) :116-122
[6]   Cannulated screw fixation and plate fixation for displaced intraarticular calcaneus fracture: A meta-analysis of randomized controlled trials [J].
Fan, Baoyou ;
Zhou, Xianhu ;
Wei, Zhijian ;
Ren, Yiming ;
Lin, Wei ;
Hao, Yan ;
Shi, Guidong ;
Feng, Shiqing .
INTERNATIONAL JOURNAL OF SURGERY, 2016, 34 :64-72
[7]   Percutaneous Robot-Assisted versus Freehand S2 Iliosacral Screw Fixation in Unstable Posterior Pelvic Ring Fracture [J].
Han, Wei ;
Zhang, Teng ;
Su, Yong-Gang ;
Zhao, Chun-Peng ;
Zhou, Li ;
Wu, Xin-Bao ;
Wang, Jun-Qiang .
ORTHOPAEDIC SURGERY, 2022, 14 (02) :221-228
[8]   Characteristics of anterior inferior calcaneal cortex [J].
Harnroongroj, T. ;
Jiamamornrat, S. ;
Tharmviboonsri, T. .
FOOT AND ANKLE SURGERY, 2019, 25 (03) :323-326
[9]   Displaced intra-articular calcaneal fractures: 15-Year follow-up of a randomised controlled trial of conservative versus operative treatment [J].
Ibrahim, T. ;
Rowsell, M. ;
Rennie, W. ;
Brown, A. R. ;
Taylor, G. J. S. ;
Gregg, P. J. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (07) :848-855
[10]   Mini-plate fixation via sinus tarsi approach is superior to cannulated screw in intra-articular calcaneal fractures: A prospective randomized study [J].
Kir, Mustafa C. ;
Ayanoglu, Semih ;
Cabuk, Haluk ;
Dedeoglu, Suleyman S. ;
Imren, Yunus ;
Karslioglu, Bulent ;
Yuce, Ali ;
Gurbuz, Hakan .
JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (03)