A comparative study of quantitative metrics in chemical exchange saturation transfer imaging for grading gliomas in adults

被引:3
作者
Liu, Ruibin [1 ]
Wang, Xianlong [2 ]
Zhao, Zhiyong [1 ]
Wen, Qingqing [1 ]
Liu, Tingting [1 ]
Wu, Dan [1 ]
Wen, Zhibo [2 ]
Zhang, Yi [1 ]
机构
[1] Zhejiang Univ, Coll Biomed Engn & Instrument Sci, Dept Biomed Engn, Key Lab Biomed Engn,Minist Educ, Hangzhou, Zhejiang, Peoples R China
[2] Southern Med Univ, Zhujiang Hosp, Dept Radiol, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Chemical exchange saturation transfer (CEST); Tumor grading; Z -spectrum fitting; Fit -free metrics; Fit -based metrics; CENTRAL-NERVOUS-SYSTEM; PROTON-TRANSFER APT; MAGNETIZATION-TRANSFER; CEST-MRI; BRAIN; CLASSIFICATION; CONTRAST; TUMORS; WATER; PH;
D O I
10.1016/j.mri.2022.11.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the performance of different chemical exchange saturation transfer (CEST) metrics for grading gliomas with semiautomatically defined regions of interest (ROIs). Methods: Thirty-eight adult subjects were included, including 23 high-grade gliomas and 15 low-grade gliomas confirmed by histopathology. The B0-corrected CEST z-spectra were first calculated with magnetization transfer ratio asymmetry (MTRasym) analysis at frequency offsets of 3.5, 3, 2.5, 2, 1.5, and 1 ppm to obtain the fit-free metrics and subsequently fitted with three Lorentzian functions denoting direct water saturation (DS), amide proton transfer (APT), and combined semisolid magnetization transfer and nuclear Overhauser enhancement (MT & NOE) effects to derive the fit-based metrics. Wilcoxon rank-sum test was performed to determine if a statistically significant difference was present in the CEST metrics between low- and high-grade gliomas. Receiver operating characteristic (ROC) curves were used to evaluate the differentiation of CEST metrics between low- and high-grade gliomas. Pearson correlation coefficients were employed to evaluate the correlations of CEST metrics. Results: For the fit-free metrics, the highest areas under the curve (AUCs) of 0.85, 0.88, and 0.88, corresponding to MTRasym, MTRnormref (normalization by the reference scan), and MTRRex (subtraction of inverse z-spectra), respectively, were obtained at 3 ppm across various frequency offsets. In addition, the AUCs generated from the fit-based metrics (0.88-0.90) were higher than those generated from the fit-free metrics at 3 ppm. Conclusion: The results of this preliminary study indicate that fit-free CEST metrics at 3 ppm are superior to the other frequency offsets for grading human brain gliomas. The fit-based metrics manifested improved differentiation between low- and high-grade gliomas compared to the fit-free CEST metrics.
引用
收藏
页码:50 / 59
页数:10
相关论文
共 50 条
  • [31] Amide Proton Transfer-Chemical Exchange Saturation Transfer Imaging of Intracranial Brain Tumors and Tumor-like Lesions: Our Experience and a Review
    Koike, Hirofumi
    Morikawa, Minoru
    Ishimaru, Hideki
    Ideguchi, Reiko
    Uetani, Masataka
    Miyoshi, Mitsuharu
    DIAGNOSTICS, 2023, 13 (05)
  • [32] Whole-brain chemical exchange saturation transfer imaging with optimized turbo spin echo readout
    Zhang, Yi
    Yong, Xingwang
    Liu, Ruibin
    Tang, Jibin
    Jiang, Hongjie
    Fu, Caixia
    Wei, Ruili
    Hsu, Yi-Cheng
    Sun, Yi
    Luo, Benyan
    Wu, Dan
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (03) : 1161 - 1172
  • [33] Nuclear Overhauser Enhancement Mediated Chemical Exchange Saturation Transfer Imaging at 7 Tesla in Glioblastoma Patients
    Paech, Daniel
    Zaiss, Moritz
    Meissner, Jan-Eric
    Windschuh, Johannes
    Wiestler, Benedikt
    Bachert, Peter
    Neumann, Jan Oliver
    Kickingereder, Philipp
    Schlemmer, Heinz-Peter
    Wick, Wolfgang
    Nagel, Armin Michael
    Heiland, Sabine
    Ladd, Mark Edward
    Bendszus, Martin
    Radbruch, Alexander
    PLOS ONE, 2014, 9 (08):
  • [34] Determination of an optimally sensitive and specific chemical exchange saturation transfer MRI quantification metric in relevant biological phantoms
    Ray, Kevin J.
    Larkin, James R.
    Tee, Yee K.
    Khrapitchev, Alexandre A.
    Karunanithy, Gogulan
    Barber, Michael
    Baldwin, Andrew J.
    Chappell, Michael A.
    Sibson, Nicola R.
    NMR IN BIOMEDICINE, 2016, 29 (11) : 1624 - 1633
  • [35] Molecular imaging of cancer by glucosamine chemical exchange saturation transfer MRI: A preclinical study
    Rivlin, Michal
    Navon, Gil
    NMR IN BIOMEDICINE, 2021, 34 (02)
  • [36] pH Mapping of Gliomas Using Quantitative Chemical Exchange Saturation Transfer MRI: Quasi-Steady-State, Spillover-, and MT-Corrected Omega Plot Analysis
    Liu, Ying
    Wu, Yin
    Ji, Yang
    Zhao, Botao
    Jin, Ziyi
    Ju, Shenghong
    Chu, Ying-Hua
    Liebig, Patrick Alexander
    Wang, He
    Li, Cong
    Zhang, Xiao-Yong
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (04) : 1444 - 1455
  • [37] Advances in diffuse glioma assessment: preoperative and postoperative applications of chemical exchange saturation transfer
    Deng, Hua-Zhen
    Zhang, Han-Wen
    Huang, Biao
    Deng, Jin-Huan
    Luo, Si-Ping
    Li, Wei-Hua
    Lei, Yi
    Liu, Xiao-Lei
    Lin, Fan
    FRONTIERS IN NEUROSCIENCE, 2024, 18
  • [38] The diagnostic efficacy of amide proton transfer imaging in grading gliomas and predicting tumor proliferation
    Chen, Yingqian
    Li, Xinbei
    Song, Yukun
    Zhu, Xiaolei
    Zhao, Jing
    Yan, Xu
    Wang, Jingyan
    Fan, Miao
    Chu, Jianping
    NEUROREPORT, 2019, 30 (02) : 139 - 144
  • [39] Uniform magnetization transfer in chemical exchange saturation transfer magnetic resonance imaging
    Lee, Jae-Seung
    Parasoglou, Prodromos
    Xia, Ding
    Jerschow, Alexej
    Regatte, Ravinder R.
    SCIENTIFIC REPORTS, 2013, 3
  • [40] Quantifying amide proton exchange rate and concentration in chemical exchange saturation transfer imaging of the human brain
    Heo, Hye-Young
    Han, Zheng
    Jiang, Shanshan
    Schar, Michael
    van Zijl, Peter C. M.
    Zhou, Jinyuan
    NEUROIMAGE, 2019, 189 : 202 - 213