Effects of indwelling centrally inserted central catheter on tip location of peripherally inserted central catheter with intracavitary electrocardiogram guidance: A retrospective case-control study

被引:2
作者
Sun, Wenyan [1 ]
Li, Jiaqian [1 ]
Liu, Bing [1 ]
Liu, Yue [1 ]
Ge, Ruibin [1 ]
Wang, Kai [1 ]
Zhang, Jingyan [1 ]
Wu, Xinjuan [2 ]
机构
[1] Peking Union Med Coll Hosp, Dept Clin Nutr, Beijing, Peoples R China
[2] Peking Union Med Coll Hosp, Dept Nursing, 1 Shuaifuyuan, Beijing 100730, Peoples R China
基金
中国国家自然科学基金;
关键词
Peripherally inserted central catheter; centrally inserted central catheter; intracavitary electrocardiogram; tip location; CENTRAL VENOUS CATHETERS; ECG METHOD; PICC; COMPLICATIONS; PLACEMENT; SUPERIOR; CVC;
D O I
10.1177/11297298211015088
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Intracavity electrocardiogram (IC-ECG) guidance is an effective technology for monitoring the tip locations of centrally inserted central catheters (CICCs) and peripherally inserted central catheters (PICCs). However, for patients with an indwelling CICC, there has been no study on whether the CICC affects PICC tip positioning with IC-ECG guidance. Methods: Thirty people with a CICC requiring PICC insertion, matched with age to controls without a CICC. The stability of IC-ECG waveforms, the amplitude of P-waves, and the accuracy of PICC tip location were compared. Results: There was no significant difference in the stability of the IC-ECG waveforms (chi(2) = 0.22, p = 0.64). The amplitudes of baseline P-waves and ideal P-waves also showed no significant difference (t1 = 0.06, p1 = 0.96, t2 = 0.80, p2 = 0.43). Neither the accuracy of tip location (chi(2) = 1.40, p = 0.50) nor the distance of PICC tip (t = -0.03, p = 0.98) were significantly different. Conclusion: For patients with an indwelling CICC, the position of PICC tip can be accurately determined by the dynamic changes in the P-wave amplitude.
引用
收藏
页码:379 / 384
页数:6
相关论文
共 28 条
  • [1] Effectiveness of the ECG method in the correct positioning of PICC type central venous catheters in patients with atrial fibrillation
    Albertini, Fabrizio
    Struglia, Manuela
    Faraone, Vincenzo
    Fioravanti, Roberto
    Boursier Niutta, Stefano
    [J]. MINERVA CARDIOANGIOLOGICA, 2019, 67 (03): : 207 - 213
  • [2] [Anonymous], 2017, Home Healthc Now, V35, pE1
  • [3] Anatomy of the Superior Vena Cava and Brachiocephalic Veins
    Bennett, W. Frederick
    Altaf, Fawaz
    Deslauriers, Jean
    [J]. THORACIC SURGERY CLINICS, 2011, 21 (02) : 197 - +
  • [4] Butts R., 2015, J ASS VASC ACCESS, V20, P255
  • [5] Adherence to Central-Line Insertion Practices (CLIP) with Peripherally Inserted Central Catheters (PICC) and Central Venous Catheters (CVC): A Prospective Study of 50 Hospitals in China
    Chen, Wensen
    Yang, Yiqun
    Li, Huifen
    Huang, Xiaoqiang
    Zhang, Weihong
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2018, 39 (01) : 122 - 123
  • [6] Elli S, 2016, ASSIST INFERM RIC, V35, P174, DOI 10.1702/2621.26950
  • [7] Gana C, 2016, J ASS VASC ACCESS, V21, P242
  • [8] Gapp J, 2017, CUREUS J MED SCIENCE, V9, DOI 10.7759/cureus.1308
  • [9] Peripherally inserted central catheter- related complications in cancer patients: a prospective study of over 50,000 catheter days
    Kang, Junren
    Chen, Wei
    Sun, Wenyan
    Ge, Ruibin
    Li, Hailong
    Ma, Enling
    Su, Qingxia
    Cheng, Fang
    Hong, Jinhua
    Zhang, Yuanjuan
    Lei, Cheng
    Wang, Xinchuan
    Jin, Aiyun
    Liu, Wanli
    [J]. JOURNAL OF VASCULAR ACCESS, 2017, 18 (02) : 153 - 157
  • [10] A randomized controlled study of bedside electrocardiograph-guided tip location technique & the traditional chest radiography tip location technique for peripherally inserted central venous catheter in cancer patients
    Li, AiMin
    Jiao, JianGuo
    Zhang, Ying
    Tian, Li
    Miao, JinHong
    Hao, XiaoLi
    Sun, ZhenChang
    Sun, QiaoZhi
    [J]. INDIAN JOURNAL OF MEDICAL RESEARCH, 2018, 147 : 477 - 483