Reliability of tomographic 3D ultrasound in measuring internal carotid artery plaque volume

被引:0
作者
Alzahrani, Adel [1 ,2 ]
Sultan, Salahaden R. [3 ,4 ]
Aslam, Mohammed [2 ]
机构
[1] King Abdullah Med City, Dept Diagnost Radiol, Mecca, Saudi Arabia
[2] Imperial Coll NHS Healthcare Trust, Hammersmith Hosp, Vasc Lab, London, England
[3] King Abdulaziz Univ, Fac Appl Med Sci, Dept Radiol Sci, Jeddah, Saudi Arabia
[4] King Abdulaziz Univ, Fac Appl Med Sci, Dept Radiol Sci, Jeddah 21589, Saudi Arabia
关键词
Tomographic 3D ultrasound; t3DUS; ultrasound; carotid plaque; internal carotid artery; CORRELATION-COEFFICIENTS; STENOSIS; ENDARTERECTOMY; PROGRESSION;
D O I
10.1177/02841851231199222
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Tomographic 3D ultrasound (t3DUS) is a promise imaging technique for quantifying carotid plaque through measuring the degree of stenosis and plaque volume. Carotid plaque volume (CPV) could add benefit in predicting the potential risk of stroke. Purpose: To assess the reproducibility and accuracy of t3DUS for measuring CPV within the internal carotid artery in patients undergoing carotid endarterectomy. Material and Methods: t3DUS was used to obtain CPV in vivo from 25 symptomatic patients prior to surgery. Ex vivo CPV from the carotid endarterectomy specimen was then measured using a validated saline displacement method as a reference standard. CPV for each patient was measured twice using both methods (total n= 50 per technique). Intraclass correlation coefficient (ICC) and Bland-Altman plot were used to establish bias and limit of agreement between CPV measurements. Results: There was an excellent agreement between t3DUS and reference test with respect to measuring CPV with an ICC value of 0.98 (95% confidence interval = 0.97-0.99, P < 0.001). Bias in measurements was 0.02 +/- 0.11 cm(3) (95% limit of agreement = -0.19 to 0.25). Intra-observer agreement of t3DUS CPV measurements was excellent with an ICC value of 0.95 (95% confidence interval = 0.92-0.97, P < 0.001). Bias in measurements was 0.004 +/- 0.07 cm(3) (95% limit of agreement = -0.14 to 0.15). Conclusion: t3DUS is a reproducible imaging method and showed excellent agreement with the reference standard with respect to measuring CPV. These findings suggest that t3DUS has the potential to be a valuable non-invasive tool for assessing carotid plaque burden and predicting the risk of stroke.
引用
收藏
页码:2931 / 2937
页数:7
相关论文
共 32 条
[1]   3D ultrasound measurement of change in carotid plaque volume - A tool for rapid evaluation of new therapies [J].
Ainsworth, CD ;
Blake, CC ;
Tamayo, A ;
Beletsky, V ;
Fenster, A ;
Spence, JD .
STROKE, 2005, 36 (09) :1904-1909
[2]   Correlation of peak systolic velocity and angiographic measurement of carotid stenosis revisited [J].
Alexandrov, AV ;
Brodie, DS ;
McLean, A ;
Hamilton, P ;
Murphy, J ;
Burns, PN .
STROKE, 1997, 28 (02) :339-342
[3]   RELIABILITY AND ACCURACY OF TOMOGRAPHIC 3-D ULTRASOUND FOR GRADING VESSEL STENOSIS: A PHANTOM STUDY [J].
Alzahrani, A. D. E. L. ;
Alotaibi, Sultan a. ;
Aslam, M. O. H. A. M. M. E. D. ;
Sultan, Salahaden r. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (09) :1899-1906
[4]   Tomographic 3D ultrasound for grading stenosis of superficial femoral artery [J].
Alzahrani, Adel ;
Sultan, Salahaden R. ;
Aslam, Mohammed .
PERFUSION-UK, 2024, 39 (05) :943-947
[5]   Carotid plaque volume in patients undergoing carotid endarterectomy [J].
Ball, S. ;
Rogers, S. ;
Kanesalingam, K. ;
Taylor, R. ;
Katsogridakis, E. ;
McCollum, C. .
BRITISH JOURNAL OF SURGERY, 2018, 105 (03) :262-269
[6]   Management of atherosclerotic extracranial carotid artery stenosis [J].
Bonati, Leo H. ;
Jansen, Olav ;
de Borst, Gert J. ;
Brown, Martin M. .
LANCET NEUROLOGY, 2022, 21 (03) :273-283
[7]   Three-Dimensional Echographic Evaluation of Carotid Artery Disease [J].
Calogero, Enrico ;
Fabiani, Iacopo ;
Pugliese, Nicola Riccardo ;
Santini, Veronica ;
Ghiadoni, Lorenzo ;
Di Stefano, Rossella ;
Galetta, Fabio ;
Sartucci, Ferdinando ;
Penno, Giuseppe ;
Berchiolli, Raffaella ;
Ferrari, Mauro ;
Cioni, Dania ;
Napoli, Vinicio ;
De Caterina, Raffaele ;
Di Bello, Vitantonio ;
Caramella, Davide .
JOURNAL OF CARDIOVASCULAR ECHOGRAPHY, 2018, 28 (04) :218-227
[8]   Carotid Endarterectomy Outcomes in the Elderly: A Canadian Institutional Experience [J].
Doonan, Robert James ;
Abdullah, Abdullah ;
Steinmetz-Wood, Samantha ;
Mekhaiel, Sandra ;
Steinmetz, Oren K. ;
Obrand, Daniel I. ;
Corriveau, Marc M. ;
Mackenzie, Kent S. ;
Gill, Heather L. .
ANNALS OF VASCULAR SURGERY, 2019, 59 :16-20
[9]   Randomised trial of endarterectomy for recently symptomatic carotid stenosis: final results of the MRC European carotid surgery trial (ECST) [J].
Farrell, B ;
Fraser, A ;
Sandercock, P ;
Slattery, J ;
Warlow, CP .
LANCET, 1998, 351 (9113) :1379-1387
[10]   Understanding Bland Altman analysis [J].
Giavarina, Davide .
BIOCHEMIA MEDICA, 2015, 25 (02) :141-151