Deep inspiratory breath hold assisted by continuous positive airway pressure ventilation for lung stereotactic body radiotherapy

被引:3
|
作者
Appel, S. [1 ,2 ]
Lawrence, Y. R. [1 ,2 ]
Bar, J. [2 ,3 ]
Jacobson, G. [1 ,2 ]
Marom, E. M. [2 ,4 ]
Katzman, T. [1 ,2 ]
Ben-Ayun, M. [1 ,2 ]
Dubinski, S. [1 ,2 ]
Haisraely, O. [1 ,2 ]
Weizman, N. [5 ]
Davidson, T. [6 ]
Weiss, I. [1 ,2 ]
Mansano, A. [1 ,2 ]
Goldstein, J. D. [7 ]
Symon, Z. [1 ,2 ]
机构
[1] Sheba Med Ctr, Dept Radiat Oncol, Tel Hashomer, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[3] Sheba Med Ctr, Inst Oncol, Tel Hashomer, Israel
[4] Sheba Med Ctr, Dept Radiol, Tel Hashomer, Israel
[5] Hadassah Med Ctr, Dept Radiat Oncol, Jerusalem, Israel
[6] Sheba Med Ctr, Nucl Med, Tel Hashomer, Israel
[7] Ichilov Hosp, Dept Radiat Oncol, Tel Aviv, Israel
来源
CANCER RADIOTHERAPIE | 2023年 / 27卷 / 01期
关键词
CONE-BEAM CT; RADIATION-THERAPY SBRT; MOTION MANAGEMENT; EARLY-STAGE; ABLATIVE RADIOTHERAPY; RESPIRATORY MOTION; TUMORS; CANCER; IMMOBILIZATION; IMPACT;
D O I
10.1016/j.canrad.2022.05.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. - Continuous positive airway pressure (CPAP) ventilation hyperinflates the lungs and reduces diaphragmatic motion. We hypothesized that CPAP could be safely combined with deep inspiratory breath hold (CPAP-DIBH) during lung stereotactic radiotherapy (SBRT). Material and methods. - Patients with stage-1 lung cancer or lung metastasis treated with CPAP-DIBH SBRT between 3/20175/2021 were analyzed retrospectively. Patient characteristics, treatment parameters, duration of breath holds in all sessions and tolerance to CPAP-DIBH were recorded. Local control (LC) was assessed from CT or PET-CT imaging. The distances between the tumor and mediastinal organs at risk (OAR) in centrally located tumors using either free breathing (FB) or CPAP-DIBH were compared. Toxicity was graded retrospectively. Results. - Forty-five patients with 71 lesions were treated with CPAP-DIBH SBRT. Indications for CPAP-DIBH were prior radiation (35/71, 65%), lower lobe location (34/71, 48%), multiple lesions (26/71, 36.6%) and proximity to mediastinal OAR (7/71, 10%). Patient characteristics were: F:M 43%: 57%; mean gross tumor volume 4.5 cm3 (SD 7.9), mean planning target volume 20 cm3 (SD 27), primary: metastatic lesions (7%:93%). Mean radiation dose was 52.5 Gray (SD3.5). Mean lung volume was 5292 cm3 (SD 1106). Mean duration of CPAP-DIBH was 41.3 s (IQR 3146.8). LC at 2 years was 89.5% (95% CI 7695.5). In patients with central lesions, the distance between the tumor and mediastinal OAR increased from 0.84 cm (SD 0.65) with FB to 1.23 cm (SD 0.8) with CPAP-DIBH (p = 0.002). Most patients tolerated CPAP well and completed all treatments after starting therapy. Three patients did not receive treatment: 2 were unable to tolerate CPAP and 1 had syncope (pre-existing). Toxicity was grade 2 in 4/65 (6%) and grade 3 in 1/65 (1.5%). There was no grade 2 or higher esophageal or tracheal toxicities. Conclusion. - CPAP-DIBH assisted lung SBRT was tolerated well and was associated with minimal toxicity and favorable LC. This technique may be considered when treating multiple lung lesions, lesions located in the lower lobes or adjacent to mediastinal OAR. (c) 2022 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 50 条
  • [1] Continuous positive airway pressure with deep inspiration breath hold in left-sided breast radiation therapy
    Reckhow, Jensen
    Kaidar-Person, Orit
    Ben-David, Merav A.
    Ostrovski, Anna
    Ilinsky, Dina
    Goldstein, Jeffrey
    Symon, Zvi
    Galper, Shira
    MEDICAL DOSIMETRY, 2021, 46 (02) : 127 - 131
  • [2] Effect of continuous positive airway pressure administration during lung stereotactic ablative radiotherapy: a comparative planning study
    Di Perri, Dario
    Colot, Andrea
    Delor, Antoine
    Ghoul, Randa
    Janssens, Guillaume
    Lacroix, Valerie
    Matte, Pascal
    Robert, Annie
    Souris, Kevin
    Geets, Xavier
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 (06) : 591 - 599
  • [3] Application and dosimetric comparison of surface-guided deep inspiration breath-hold for lung stereotactic body radiotherapy
    Wang, Jiaxin
    Dong, Tingting
    Meng, Xiangyin
    Li, Wenbo
    Li, Nan
    Wang, Yijun
    Yang, Bo
    Qiu, Jie
    MEDICAL DOSIMETRY, 2024, 49 (04) : 372 - 379
  • [4] Feasibility and tolerability of breath-hold in liver stereotactic body radiotherapy with surface guided radiotherapy
    Turna, Menekse
    Kucukmorkoc, Esra
    Rzazade, Rashad
    Canoglu, Mehmet Dogu
    Kucuk, Nadir
    Caglar, Hale Basak
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2023, 28
  • [5] Evaluating intra-fractional tumor motion in lung stereotactic radiotherapy with deep inspiration breath-hold
    Fu, Weihua
    Zhang, Yongqian
    Mehta, Kiran
    Chen, Alex
    Musunuru, Hima Bindu
    Pucci, Pietro
    Kubis, Jason
    Huq, M. Saiful
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (08):
  • [6] Efficacy and Optimal Pressure of Continuous Positive Airway Pressure in Intensity-Modulated Radiotherapy for Locally Advanced Lung Cancer
    Park, Jaehyeon
    Yea, Ji Woon
    Oh, Se An
    Park, Jongmoo
    Park, Jae Won
    Lee, Jeong Eun
    CANCERS, 2022, 14 (17)
  • [7] Dosimetric benefits of dynamic conformal arc therapy-combined with active breath-hold in lung stereotactic body radiotherapy
    Lee, Soyoung
    Lee, Danny
    Verma, Vivek
    Waters, Danielle
    Oh, Seungjong
    Colonias, Athanasios
    Wegner, Rodney
    Pavord, Daniel
    Coopey, Bryan
    Fuhrer, Russell
    Sohn, Jason W.
    MEDICAL DOSIMETRY, 2022, 47 (01) : 54 - 60
  • [8] Radiofrequency Ablation in the Lung Complicated by Positive Airway Pressure Ventilation
    Nachiappan, Arun C.
    Sharma, Amita
    Shepard, Jo-Anne O.
    Lanuti, Michael
    ANNALS OF THORACIC SURGERY, 2010, 89 (05) : 1665 - 1667
  • [9] Optimizing target and diaphragmatic configuration, and dosimetric benefits using continuous positive airway pressure in stereotactic ablative radiotherapy for lung tumors
    Park, Jung Bin
    Lee, Joo Ho
    Chang, Ji Hyun
    Son, Jaeman
    Kwon, Seho
    Choi, Su Yun
    Shin, Hyun-Woo
    Yu, Tosol
    Kim, Hak Jae
    RADIATION ONCOLOGY JOURNAL, 2024, 42 (03): : 200 - 209
  • [10] Reproducibility of surface-based deep inspiration breath-hold technique for lung stereotactic body radiotherapy on a closed-bore gantry linac
    Nguyen, Daniel
    Reinoso, Rebeca
    Farah, Jad
    Yossi, Sena
    Lorchel, Fabrice
    Passerat, Victor
    Louet, Estelle
    Pouchard, Isabelle
    Khodri, Mustapha
    Barbet, Nicolas
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 26