Extraction-assisted voltammetric determination of homocysteine using magnetic nanoparticles modified with molecularly imprinted polymer

被引:7
|
作者
da Conceicao, Poliana [1 ]
dos Santos Neto, Antonio Gomes [2 ]
Khan, Sabir [3 ]
Tanaka, Auro A. [2 ,4 ]
Santana, Antonio Euzebio G. [1 ]
del Pilar Taboada-Sotomayor, Maria [3 ]
Goulart, Marilia O. F. [1 ,4 ]
Santos, Ana Caroline Ferreira [1 ,4 ]
机构
[1] Univ Fed Alagoas, Programa Pos graduacao Quim & Biotecnol PPGQB, Inst Quim & Biotecnol, Campus AC Simoes,Tabuleiro Martin, BR-57072970 Maceio, AL, Brazil
[2] Univ Fed Maranhao, Dept Quim, Ave Portugueses, 1966, BR-65080805 Sao Luis, MA, Brazil
[3] Univ Estadual Paulista, Inst Quim, INCT DATREM, Rua Prof Francisco Degni 55, Araraquara, SP, Brazil
[4] Natl Inst Sci & Technol Bioanalyt INCT Bio, Campinas, Brazil
关键词
Hyperhomocysteinemia; Magnetic molecularly imprinted polymer; Fe3O4; nanoparticles; Electrochemical sensor; Electroanalysis; Differential pulse voltammetry; ELECTROCHEMICAL DETERMINATION; CYSTEINE; SENSOR;
D O I
10.1007/s00604-023-05738-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A magnetic graphite-epoxy composite (m-GEC) electrochemical sensor is presented based on magnetic imprinted polymer (mag-MIP) to determine homocysteine (Hcy). Mag-MIP was synthesized via precipitation polymerization, using functionalized magnetic nanoparticles (Fe3O4) together with the template molecule (Hcy), the functional monomer 2-hydroxyethyl methacrylate (HEMA), and the structural monomer trimethylolpropane trimethacrylate (TRIM). For mag-NIP (magnetic non-imprinted polymer), the procedure was the same in the absence of Hcy. Morphological and structural properties of the resultant mag-MIP and mag-NIP were examined using TEM, FT-IR, and Vibrating Sample Magnetometer. Under optimized conditions, the m-GEC/mag-MIP sensor showed a linear range of 0.1-2 mu mol L-1, with a limit of detection (LOD) of 0.030 mu mol L-1. In addition, the proposed sensor responded selectively to Hcy compared to several interferents present in biological samples. The recovery values determined by differential pulse voltammetry (DPV) were close to 100% for natural and synthetic samples, indicating good method accuracy. The developed electrochemical sensor proves to be a suitable device for determining Hcy, with advantages related to magnetic separation and electrochemical analysis.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Electrochemical sensor based on magnetic molecularly imprinted nanoparticles at surfactant modified magnetic electrode for determination of bisphenol A
    Zhu, Lili
    Cao, Yuhua
    Cao, Guangqun
    BIOSENSORS & BIOELECTRONICS, 2014, 54 : 258 - 261
  • [32] Magnetic molecularly imprinted polymer extraction of chloramphenicol from honey
    Chen, Ligang
    Li, Bin
    FOOD CHEMISTRY, 2013, 141 (01) : 23 - 28
  • [34] Voltammetric determination of urinary 1-hydroxypyrene using molecularly imprinted polymer-modified screen-printed carbon electrodes
    Kirsch, N
    Honeychurch, KC
    Hart, JP
    Whitcombe, MJ
    ELECTROANALYSIS, 2005, 17 (07) : 571 - 578
  • [35] Fast microwave-assisted synthesis of magnetic molecularly imprinted polymer for sulfamethoxazole
    Lamaoui, Abderrahman
    Maria Palacios-Santander, Jose
    Amine, Aziz
    Cubillana-Aguilera, Laura
    TALANTA, 2021, 232
  • [36] Magnetic molecularly imprinted polymers for selective extraction and determination of naphthols
    Chen, Di
    Han, Xiaoxuan
    Wang, Qi
    Xie, Liujing
    Ai, Youhong
    Dang, Xueping
    Huang, Jianlin
    Chen, Huaixia
    MICROCHIMICA ACTA, 2017, 184 (09) : 3373 - 3379
  • [37] Methyl methacrylate magnetic molecularly imprinted polymer for gluten determination
    Limthin, Dalawan
    Chattrairat, Kunanon
    Leepheng, Pitawan
    Wisutthipat, Sawita
    Gansa, Poompun
    Klamchuen, Annop
    Phromyothin, Darinee
    JOURNAL OF METALS MATERIALS AND MINERALS, 2019, 29 (01): : 42 - 48
  • [38] Magnetic Dual-template Molecularly Imprinted Polymer Nanoparticles for the Simultaneous Determination of Acetaminophen and Codeine in Urine Samples by Ion Mobility Spectrometry
    Jafari, Mohammad T.
    Rezaei, Behzad
    Bahrami, Hajar
    ANALYTICAL SCIENCES, 2018, 34 (03) : 297 - 303
  • [39] Fabrication of an Extra Sensitive Voltammetric Sensor Using Nanoparticles of Molecularly Imprinted Polymer for Determination of Ultra-Trace Promethazine in Plasma Sample
    Alizadeh, Taher
    Ganjali, Mohammad Reza
    Akhoundian, Maedeh
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 10427 - 10441
  • [40] Selective separation and determination of diclofenac via magnetic molecularly imprinted polymer and spectrophotometry
    Pebdani, Arezou Amiri
    Shabani, Ali Mohammad Haji
    Dadfarnia, Shayessteh