Extraction-assisted voltammetric determination of homocysteine using magnetic nanoparticles modified with molecularly imprinted polymer

被引:7
|
作者
da Conceicao, Poliana [1 ]
dos Santos Neto, Antonio Gomes [2 ]
Khan, Sabir [3 ]
Tanaka, Auro A. [2 ,4 ]
Santana, Antonio Euzebio G. [1 ]
del Pilar Taboada-Sotomayor, Maria [3 ]
Goulart, Marilia O. F. [1 ,4 ]
Santos, Ana Caroline Ferreira [1 ,4 ]
机构
[1] Univ Fed Alagoas, Programa Pos graduacao Quim & Biotecnol PPGQB, Inst Quim & Biotecnol, Campus AC Simoes,Tabuleiro Martin, BR-57072970 Maceio, AL, Brazil
[2] Univ Fed Maranhao, Dept Quim, Ave Portugueses, 1966, BR-65080805 Sao Luis, MA, Brazil
[3] Univ Estadual Paulista, Inst Quim, INCT DATREM, Rua Prof Francisco Degni 55, Araraquara, SP, Brazil
[4] Natl Inst Sci & Technol Bioanalyt INCT Bio, Campinas, Brazil
关键词
Hyperhomocysteinemia; Magnetic molecularly imprinted polymer; Fe3O4; nanoparticles; Electrochemical sensor; Electroanalysis; Differential pulse voltammetry; ELECTROCHEMICAL DETERMINATION; CYSTEINE; SENSOR;
D O I
10.1007/s00604-023-05738-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A magnetic graphite-epoxy composite (m-GEC) electrochemical sensor is presented based on magnetic imprinted polymer (mag-MIP) to determine homocysteine (Hcy). Mag-MIP was synthesized via precipitation polymerization, using functionalized magnetic nanoparticles (Fe3O4) together with the template molecule (Hcy), the functional monomer 2-hydroxyethyl methacrylate (HEMA), and the structural monomer trimethylolpropane trimethacrylate (TRIM). For mag-NIP (magnetic non-imprinted polymer), the procedure was the same in the absence of Hcy. Morphological and structural properties of the resultant mag-MIP and mag-NIP were examined using TEM, FT-IR, and Vibrating Sample Magnetometer. Under optimized conditions, the m-GEC/mag-MIP sensor showed a linear range of 0.1-2 mu mol L-1, with a limit of detection (LOD) of 0.030 mu mol L-1. In addition, the proposed sensor responded selectively to Hcy compared to several interferents present in biological samples. The recovery values determined by differential pulse voltammetry (DPV) were close to 100% for natural and synthetic samples, indicating good method accuracy. The developed electrochemical sensor proves to be a suitable device for determining Hcy, with advantages related to magnetic separation and electrochemical analysis.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Extraction-assisted voltammetric determination of homocysteine using magnetic nanoparticles modified with molecularly imprinted polymer
    Poliana da Conceição
    Antonio Gomes dos Santos Neto
    Sabir Khan
    Auro A. Tanaka
    Antônio Euzébio G. Santana
    Maria del Pilar Taboada-Sotomayor
    Marília O. F. Goulart
    Ana Caroline Ferreira Santos
    Microchimica Acta, 2023, 190
  • [2] Voltammetric Determination of Valaciclovir Using a Molecularly Imprinted Polymer Modified Carbon Paste Electrode
    El Gohary, Nesrine Abdelrehim
    Madbouly, Adel
    El Nashar, Rasha Mohamed
    Mizaikoff, Boris
    ELECTROANALYSIS, 2017, 29 (05) : 1388 - 1399
  • [3] Development of magnetic nanoparticles modified with new molecularly imprinted polymer (MIPs) for selective analysis of glutathione
    Santos, Ana Caroline Ferreira
    de Araujo, Orlando R. P.
    Moura, Fabiana A.
    Khan, Sabir
    Tanaka, Auro A.
    Santana, Antonio Euzebio G.
    Pividori, Maria Isabel
    Taboada-Sotomayor, Maria del Pilar
    Goulart, Marilia O. F.
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 344
  • [4] Voltammetric determination of lactic acid in milk samples using carbon paste electrode modified with chitosan-based magnetic molecularly imprinted polymer
    Mahmoudi, Zohre
    Tashkhourian, Javad
    Hemmateenejad, Bahram
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2022, 52 (01) : 35 - 44
  • [5] Sensitive and Selective Voltammetric Determination of Ciprofloxacin Using Screen-printed Electrodes Modified with Carbon Black and Magnetic-molecularly Imprinted Polymer
    Wong, Ademar
    Santos, Anderson M.
    Silva, Tiago A.
    Moraes, Fernando C.
    Fatibello-Filho, Orlando
    Sotomayor, Maria D. P. T.
    ELECTROANALYSIS, 2023, 35 (01) : 320 - 329
  • [6] Extraction of melamine from milk using a magnetic molecularly imprinted polymer
    Anirudhan, T. S.
    Christa, J.
    Deepa, J. R.
    FOOD CHEMISTRY, 2017, 227 : 85 - 92
  • [7] Voltammetric sensing of minoxidil using a molecularly imprinted polymer (MIP)-modified carbon paste electrode
    Dehdashtian, Sara
    Hashemi, Beshare
    CHEMICAL PAPERS, 2020, 74 (01): : 157 - 165
  • [8] Electrochemical Determination of Tetracycline Using Molecularly Imprinted Polymer Modified Carbon Nanotube-Gold Nanoparticles Electrode
    Wang, Hongtao
    Zhao, Huimin
    Quan, Xie
    Chen, Shuo
    ELECTROANALYSIS, 2011, 23 (08) : 1863 - 1869
  • [9] Selective Voltammetric Determination of Dopamine Using a Palladium Particle-Modified Electrode with Molecularly Imprinted Nicotinamide Polymer
    Shaidarova, L. G.
    Chelnokova, I. A.
    Khairullina, D. Y.
    Leksina, Y. A.
    Budnikov, H. C.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (09) : 1322 - 1328
  • [10] Synthesis and application of a molecularly imprinted polymer for the voltammetric determination of famciclovir
    El Gohary, Nesrine Abdelrehim
    Madbouly, Adel
    El Nashar, Rasha Mohamed
    Mizaikoff, Boris
    BIOSENSORS & BIOELECTRONICS, 2015, 65 : 108 - 114