Real-world outcomes of continuous glucose monitoring in adults with diabetes mellitus attending an Irish tertiary hospital

被引:2
作者
Courtney, Aoife [1 ]
Smith, Diarmuid [1 ]
Forde, Hannah [1 ]
机构
[1] Beaumont Hosp, RCSI Med Sch, Dept Endocrinol & Diabet Mellitus, Dublin, Ireland
关键词
Continuous glucose monitoring; Diabetes technology; Type; 1; diabetes; 2; DAILY INSULIN INJECTIONS; GLYCEMIC CONTROL; TYPE-1; HYPOGLYCEMIA; ASSOCIATION; MANAGEMENT;
D O I
10.1007/s11845-023-03322-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Backgrounds and aimsThe American Diabetes Association/European Association for the Study of Diabetes recently recommend the preferential use of continuous glucose monitoring(CGM) over self-monitoring of blood glucose for the management of type 1 diabetes (T1DM). For most adults with T1DM, the recommended target time in range is > 70% with < 4% time below range. In Ireland, CGM use has become increasingly popular since 2021. We aimed to audit adult CGM use and analyse CGM metrics in our cohort of adults with diabetes attending a tertiary diabetes centre.MethodsPeople with diabetes who were using DEXCOM G6 CGM devices, and sharing their data with the healthcare team on the DEXCOM CLARITY for healthcare professionals platform were included in the audit. Clinical information, glycated haemoglobin (HbA1c) and CGM metrics were gathered retrospectively from medical records and the DEXCOM CLARITY platform.ResultsData were available for 119 CGM users, 96.9% with T1DM, median age 36 years (IQR = 20) and median diabetes duration 17 years (IQR = 20). Fifty-three per cent of the cohort was male. Mean time in range was 56.2% (SD = 19.2) and mean time below range was 2.3% (SD = 2.6). Mean HbA1c in CGM users was 56.7 mmol/mol (SD = 13.1). This represented a decrease of 6.7 mmol/mol compared to the last HbA1c measurements available pre-commencement of CGM (p <= 0.0001, CI 4.4-8.9). The percentage of people in this cohort with a HbA1c < 53 mmol/mol was 40.6% (n = 39/96), compared to 17.5% (n = 18/103) pre-commencement of CGM.ConclusionsOur study highlights the challenges in optimising the use of CGM. Our team aims to focus on providing additional education to CGM users, more frequent touch-base virtual reviews and increasing access to hybrid closed-loop insulin pump therapy.
引用
收藏
页码:2763 / 2768
页数:6
相关论文
共 50 条
[21]   Impact of continuous glucose monitoring on hospitalizations and glucose control in people with type 2 diabetes: real-world analysis [J].
Garg, Satish K. ;
Hirsch, Irl B. ;
Repetto, Enrico ;
Snell-Bergeon, Janet ;
Ulmer, Brian ;
Perkins, Christopher ;
Bergenstal, Richard M. .
DIABETES OBESITY & METABOLISM, 2024, 26 (11) :5202-5210
[22]   The effects of continuous glucose monitoring system on patient outcomes and associated costs in a real-world setting [J].
Triki, Noa ;
Yekutiel, Naama ;
Levi, Lilly ;
Azuri, Joseph .
DIABETIC MEDICINE, 2021, 38 (05)
[23]   Diabetes Therapy Podcast: Real-World Data for Glucose Sensing Technologies in Type 1 Diabetes [J].
Oliver, Nick .
DIABETES THERAPY, 2023, 14 (01) :1-10
[24]   Real-World Outcomes of Glucose Sensor Use in Type 1 Diabetes-Findings from a Large UK Centre [J].
Lee, Kyuhan ;
Gunasinghe, Shakthi ;
Chapman, Alyson ;
Findlow, Lynne A. ;
Hyland, Jody ;
Ohol, Sheetal ;
Urwin, Andrea ;
Rutter, Martin K. ;
Schofield, Jonathan ;
Thabit, Hood ;
Leelarathna, Lalantha .
BIOSENSORS-BASEL, 2021, 11 (11)
[25]   Evaluating the effect of Semaglutide as add-on therapy on glycemic control and continuous glucose monitoring outcomes in adults with type 1 diabetes: A two-year real-world data study [J].
Al Hayek, Ayman ;
Klonoff, David C. ;
Al Zahrani, Wael M. ;
Ibrahim, Suzan Eid ;
Al Dawish, Mohammed A. .
JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2025, 39 (07)
[26]   Clinical interpretation of the flash continuous glucose monitoring data out of range in type 2 diabetes: A real-world study [J].
Wen, Xiaofang ;
Ou, Tingting ;
Zeng, Nan ;
Li, Xiaowei ;
Luo, Ai ;
Xu, Xiaojia ;
Li, Wangen ;
Du, Tao .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2021, 178
[27]   Importance of continuous glucose monitoring in the treatment of diabetes mellitus [J].
Moon, Sun Joon ;
Lee, Won-Young .
JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2023, 66 (07) :432-438
[28]   Comparison of accuracy between flash glucose monitoring and continuous glucose monitoring in patients with type 2 diabetes mellitus undergoing hemodialysis [J].
Matoba, Kenta ;
Hayashi, Akinori ;
Shimizu, Naoya ;
Moriguchi, Ibuki ;
Kobayashi, Naoyuki ;
Shichiri, Masayoshi .
JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2020, 34 (11)
[29]   Real-World Analysis of Therapeutic Outcome in Type 1 Diabetes Mellitus at a Tertiary Care Center [J].
Kietaibl, Antonia ;
Riedl, Michaela ;
Bozkurt, Latife .
DIABETES & METABOLISM JOURNAL, 2022, 46 (01) :149-153
[30]   Real-time continuous glucose monitoring improves postoperative glucose control in people with type 2 diabetes mellitus undergoing coronary artery bypass grafting: A randomized clinical trial [J].
Son, Heejun ;
Sohn, Suk Ho ;
Kim, Hyun Ah ;
Choe, Hun Jee ;
Lee, Hyunsuk ;
Jung, Hye Seung ;
Cho, Young Min ;
Park, Kyong Soo ;
Hwang, Ho Young ;
Kwak, Soo Heon .
DIABETES OBESITY & METABOLISM, 2025, 27 (04) :1836-1844