Simultaneous determination of bromoxynil and MCPA in commercial samples and raw materials using reversed phase high performance liquid chromatography

被引:1
|
作者
Yar, Ahmed [1 ]
Ansari, Tariq Mahmood [1 ]
Rehman, Faariah [1 ]
Raza, Asad [2 ]
Riaz, Umair [3 ]
Iqbal, Rashid [4 ]
Al-Mohaimeed, Amal M. [5 ]
Al-onazi, Wedad A. [5 ]
Rizwan, Muhammad [6 ]
机构
[1] Bahauddin Zakariya Univ, Inst Chem Sci, Multan 68000, Pakistan
[2] Govt Postgrad Coll Civil Lines, Dept Chem, Multan 68000, Punjab, Pakistan
[3] MNS Univ Agr, Dept Soil & Environm Sci, Multan 66000, Pakistan
[4] Islamia Univ Bahawalpur, Dept Agron, Bahwalpur 63100, Pakistan
[5] King Saud Univ, Coll Sci, Dept Chem, POB 22452, Riyadh 11495, Saudi Arabia
[6] Univ Bonn, Inst Crop Sci & Resource Conservat INRES, D-53115 Bonn, Germany
关键词
Bromoxynil; MCPA; RP-HPLC; Commercial samples; Determination; Validation; ACIDIC PESTICIDES; EXPOSURE; RESIDUES; HEALTH; COSTS; WATER; HPLC;
D O I
10.1186/s13065-024-01154-x
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study encompasses a quick, efficient, repeatable and reproducible analytical method for simultaneous determination of Bromoxynil (3, 5-Dibromo-4-hydroxybenzonitrile) and MCPA (2-methyl-4-chlorophenoxyacetic acid) using RP-HPLC with UV-Detector. Bromoxynil + MCPA is one of the most selective post emergent herbicide formulations for the control of important broad leaf weeds infesting small grains (wheat, barley, oats, rye), conservation reserve program areas and grass grown for seed. Optimum weed control is achieved when Bromoxynil + MCPA is applied to actively growing weed seedlings. So, a simple, repeatable, reproducible and efficient simultaneous analytical method was developed for Bromoxynil + MCPA. The developed method was applied for the detection and quantitation of these pesticides in formulations and raw materials with excellent recoveries. It was validated according to ICH Guidelines with excellent linearity R2 = 0.992 for Bromoxynil and 0.998 for MCPA. For Bromoxynil, LOD = 1.57 mg/L and LOQ = 5.22 mg/L while for MCPA the LOD = 1.08 mg/L and LOQ = 3.62 mg/L was found. The proposed method has shown high precision (RSD %) 0.06% and 0.11% for Bromoxynil and MCPA respectively while the trueness has been calculated in terms of recovery percentage obtained as "mean value of Bromoxynil 99.53% and MCPA 100.10%" which is excellent under optimized conditions. For repeatability and reproducibility, five replicate readings of standard and sample were taken and had found within acceptable limits of relative standard deviation (RSD <= +/- 2%). Finally, the robustness of the developed method was determined by changing flow rate and mobile phase ratios that has found within the permissible limits (% RSD NMT 1.5). So, the proposed analytical method has found to be more precise, valid and accurate at commercial scale.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Specific features of the determination of betacyanins by reversed-phase high-performance liquid chromatography
    Saenko, I. I.
    Deineka, V. I.
    Deineka, L. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (07) : 892 - 896
  • [42] Specific features of the determination of betacyanins by reversed-phase high-performance liquid chromatography
    I. I. Saenko
    V. I. Deineka
    L. A. Deineka
    Journal of Analytical Chemistry, 2015, 70 : 892 - 896
  • [43] Determination of clonixin in plasma and urine by reversed-phase high-performance liquid chromatography
    Bica, A
    Farinha, A
    Blume, H
    Barbosa, CM
    JOURNAL OF CHROMATOGRAPHY A, 2000, 889 (1-2) : 135 - 141
  • [44] Determination of Constituents in Hair Dyes by Reversed-phase High-Performance Liquid Chromatography
    Bao Hai SHAO
    Jian Wei YAN
    Xiu Zhu XU
    Xiao Yun FU(Department of Chemistry
    ChineseChemicalLetters, 2000, (06) : 471 - 472
  • [45] Determination of constituents in hair dyes by reversed-phase high-performance liquid chromatography
    Shao, BH
    Yan, JW
    Xu, XZ
    Fu, XY
    CHINESE CHEMICAL LETTERS, 2000, 11 (06) : 471 - 472
  • [46] Simultaneous determination of tetracyclines, fluoroquinolones, and sulfonamides in chicken manure using solid-phase extraction and high performance liquid chromatography
    Yu Peiyao
    Chen Chuansheng
    Liu Hanbing
    Deng Yanling
    Xue Nandong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2019, 37 (05) : 518 - 524
  • [47] Quantification of methoprene aerosol deposition using reversed-phase high-performance liquid chromatography
    Norton, Amie E.
    Brabec, Daniel L.
    Tilley, Michael
    Yeater, Kathleen M.
    Scheff, Deanna S.
    JOURNAL OF STORED PRODUCTS RESEARCH, 2022, 99
  • [48] Simultaneous Determination of Three Naphthoquinones in the Leaves of Impatiens Balsamina L. by Reversed-phase High-performance Liquid Chromatography
    Sakunphueak, Athip
    Panichayupakaranant, Pharkphoom
    PHYTOCHEMICAL ANALYSIS, 2010, 21 (05) : 444 - 450
  • [49] Factorial design-assisted reversed phase-high performance liquid chromatography method for simultaneous determination of fluconazole, itraconazole and terbinafine
    Roshdy, Aya
    Elmansi, Heba
    Shalan, Shereen
    El-Brashy, Amina
    ROYAL SOCIETY OPEN SCIENCE, 2021, 8 (02):
  • [50] Determination of deracoxib in feline plasma samples using high performance liquid chromatography
    Cox, SK
    Roark, J
    Gassel, A
    Tobias, K
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 819 (01): : 181 - 184