Simultaneous determination of bromoxynil and MCPA in commercial samples and raw materials using reversed phase high performance liquid chromatography

被引:1
|
作者
Yar, Ahmed [1 ]
Ansari, Tariq Mahmood [1 ]
Rehman, Faariah [1 ]
Raza, Asad [2 ]
Riaz, Umair [3 ]
Iqbal, Rashid [4 ]
Al-Mohaimeed, Amal M. [5 ]
Al-onazi, Wedad A. [5 ]
Rizwan, Muhammad [6 ]
机构
[1] Bahauddin Zakariya Univ, Inst Chem Sci, Multan 68000, Pakistan
[2] Govt Postgrad Coll Civil Lines, Dept Chem, Multan 68000, Punjab, Pakistan
[3] MNS Univ Agr, Dept Soil & Environm Sci, Multan 66000, Pakistan
[4] Islamia Univ Bahawalpur, Dept Agron, Bahwalpur 63100, Pakistan
[5] King Saud Univ, Coll Sci, Dept Chem, POB 22452, Riyadh 11495, Saudi Arabia
[6] Univ Bonn, Inst Crop Sci & Resource Conservat INRES, D-53115 Bonn, Germany
关键词
Bromoxynil; MCPA; RP-HPLC; Commercial samples; Determination; Validation; ACIDIC PESTICIDES; EXPOSURE; RESIDUES; HEALTH; COSTS; WATER; HPLC;
D O I
10.1186/s13065-024-01154-x
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study encompasses a quick, efficient, repeatable and reproducible analytical method for simultaneous determination of Bromoxynil (3, 5-Dibromo-4-hydroxybenzonitrile) and MCPA (2-methyl-4-chlorophenoxyacetic acid) using RP-HPLC with UV-Detector. Bromoxynil + MCPA is one of the most selective post emergent herbicide formulations for the control of important broad leaf weeds infesting small grains (wheat, barley, oats, rye), conservation reserve program areas and grass grown for seed. Optimum weed control is achieved when Bromoxynil + MCPA is applied to actively growing weed seedlings. So, a simple, repeatable, reproducible and efficient simultaneous analytical method was developed for Bromoxynil + MCPA. The developed method was applied for the detection and quantitation of these pesticides in formulations and raw materials with excellent recoveries. It was validated according to ICH Guidelines with excellent linearity R2 = 0.992 for Bromoxynil and 0.998 for MCPA. For Bromoxynil, LOD = 1.57 mg/L and LOQ = 5.22 mg/L while for MCPA the LOD = 1.08 mg/L and LOQ = 3.62 mg/L was found. The proposed method has shown high precision (RSD %) 0.06% and 0.11% for Bromoxynil and MCPA respectively while the trueness has been calculated in terms of recovery percentage obtained as "mean value of Bromoxynil 99.53% and MCPA 100.10%" which is excellent under optimized conditions. For repeatability and reproducibility, five replicate readings of standard and sample were taken and had found within acceptable limits of relative standard deviation (RSD <= +/- 2%). Finally, the robustness of the developed method was determined by changing flow rate and mobile phase ratios that has found within the permissible limits (% RSD NMT 1.5). So, the proposed analytical method has found to be more precise, valid and accurate at commercial scale.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Simultaneous Determination of Cysteamine and Cystamine in Cosmetics by Ion-Pairing Reversed-Phase High-Performance Liquid Chromatography
    Kim, Yejin
    Na, Dong Hee
    TOXICOLOGICAL RESEARCH, 2019, 35 (02) : 161 - 165
  • [32] Simultaneous determination of three alkaloids in Huangbo using an ionic liquid as a mobile phase additive in reversed-phase liquid chromatography
    Ding, Xiaoyuan
    Tang, Yan
    Sun, Ailing
    Liu, Renmin
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (03) : 374 - 380
  • [33] Determination of Enrofloxacin Residues in Commercial Broilers Using High Performance Liquid Chromatography
    Aslam, Bilal
    Kousar, Naheed
    Javed, Ijaz
    Raza, Ahmad
    Ali, Asghar
    Khaliq, Tanweer
    Muhammad, Faqir
    Khan, Junaid Ali
    INTERNATIONAL JOURNAL OF FOOD PROPERTIES, 2016, 19 (11) : 2463 - 2470
  • [34] Simultaneous Determination of Iodide and Iodothyronines by Reversed-Phase High-Performance Liquid Chromatography with an Alkylammonium Phosphate-Containing Mobile Phase
    Miyashita, Masahiro
    Seyama, Yoshiyuki
    Obata, Toshio
    BUNSEKI KAGAKU, 2011, 60 (02) : 149 - 156
  • [35] Simultaneous Determination of Zidovudine and Lamivudine in Plasma Samples Using Miniaturized Homogenous Liquid–Liquid Extraction and High-Performance Liquid Chromatography
    Zahra Rouhollah Heydari
    Majid Lotfi
    Journal of Analytical Chemistry, 2018, 73 : 1105 - 1110
  • [36] Determination of Glufosinate-P-Ammonium in Soil Using Precolumn Derivation and Reversed-Phase High-Performance Liquid Chromatography
    Chen, Lin
    Kong, Shun
    Wang, Guodong
    Yan, Xiaoju
    Zhang, Xuemei
    Kong, Xiangji
    Bu, Yuanqing
    WATER, 2022, 14 (11)
  • [37] Determination of Fluoxetine in Blood Samples by High-Performance Liquid Chromatography Using Derivatization Reagent
    Wozniakiewicz, M.
    Kuczara, J.
    Koscielniak, P.
    CHEMIA ANALITYCZNA, 2009, 54 (04): : 667 - 677
  • [38] Simultaneous determination of related substances of telmisartan and hydrochlorothiazide in tablet dosage form by using reversed phase high performance liquid chromatographic method
    Mukhopadhyay, Sutirtho
    Kadam, Kiran
    Sawant, Laxman
    Nachane, Dhanashree
    Pandita, Nancy
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2011, 3 (03): : 375 - 383
  • [39] Simultaneous evaluation of neonicotinoids in cotton seed cake using reverse phase high-performance liquid chromatography
    Mohan, Chander
    Kumar, Yogesh
    Madan, Jyotsana
    Saxena, Navneet
    Lai, D.
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2009, 89 (07) : 1250 - 1252
  • [40] Direct determination of trace aluminum with quercetin by reversed-phase high performance liquid chromatography
    Lian, HZ
    Kang, WF
    Bi, SP
    Arkin, Y
    Shao, DL
    Li, D
    Chen, YJ
    Dai, LM
    Gan, N
    Tian, LC
    TALANTA, 2004, 62 (01) : 43 - 50