Simultaneous determination of bromoxynil and MCPA in commercial samples and raw materials using reversed phase high performance liquid chromatography

被引:1
|
作者
Yar, Ahmed [1 ]
Ansari, Tariq Mahmood [1 ]
Rehman, Faariah [1 ]
Raza, Asad [2 ]
Riaz, Umair [3 ]
Iqbal, Rashid [4 ]
Al-Mohaimeed, Amal M. [5 ]
Al-onazi, Wedad A. [5 ]
Rizwan, Muhammad [6 ]
机构
[1] Bahauddin Zakariya Univ, Inst Chem Sci, Multan 68000, Pakistan
[2] Govt Postgrad Coll Civil Lines, Dept Chem, Multan 68000, Punjab, Pakistan
[3] MNS Univ Agr, Dept Soil & Environm Sci, Multan 66000, Pakistan
[4] Islamia Univ Bahawalpur, Dept Agron, Bahwalpur 63100, Pakistan
[5] King Saud Univ, Coll Sci, Dept Chem, POB 22452, Riyadh 11495, Saudi Arabia
[6] Univ Bonn, Inst Crop Sci & Resource Conservat INRES, D-53115 Bonn, Germany
关键词
Bromoxynil; MCPA; RP-HPLC; Commercial samples; Determination; Validation; ACIDIC PESTICIDES; EXPOSURE; RESIDUES; HEALTH; COSTS; WATER; HPLC;
D O I
10.1186/s13065-024-01154-x
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study encompasses a quick, efficient, repeatable and reproducible analytical method for simultaneous determination of Bromoxynil (3, 5-Dibromo-4-hydroxybenzonitrile) and MCPA (2-methyl-4-chlorophenoxyacetic acid) using RP-HPLC with UV-Detector. Bromoxynil + MCPA is one of the most selective post emergent herbicide formulations for the control of important broad leaf weeds infesting small grains (wheat, barley, oats, rye), conservation reserve program areas and grass grown for seed. Optimum weed control is achieved when Bromoxynil + MCPA is applied to actively growing weed seedlings. So, a simple, repeatable, reproducible and efficient simultaneous analytical method was developed for Bromoxynil + MCPA. The developed method was applied for the detection and quantitation of these pesticides in formulations and raw materials with excellent recoveries. It was validated according to ICH Guidelines with excellent linearity R2 = 0.992 for Bromoxynil and 0.998 for MCPA. For Bromoxynil, LOD = 1.57 mg/L and LOQ = 5.22 mg/L while for MCPA the LOD = 1.08 mg/L and LOQ = 3.62 mg/L was found. The proposed method has shown high precision (RSD %) 0.06% and 0.11% for Bromoxynil and MCPA respectively while the trueness has been calculated in terms of recovery percentage obtained as "mean value of Bromoxynil 99.53% and MCPA 100.10%" which is excellent under optimized conditions. For repeatability and reproducibility, five replicate readings of standard and sample were taken and had found within acceptable limits of relative standard deviation (RSD <= +/- 2%). Finally, the robustness of the developed method was determined by changing flow rate and mobile phase ratios that has found within the permissible limits (% RSD NMT 1.5). So, the proposed analytical method has found to be more precise, valid and accurate at commercial scale.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Simultaneous determination of bromoxynil and MCPA in commercial samples and raw materials using reversed phase high performance liquid chromatography
    Ahmed Yar
    Tariq Mahmood Ansari
    Faariah Rehman
    Asad Raza
    Umair Riaz
    Rashid Iqbal
    Amal M. Al-Mohaimeed
    Wedad A. Al-onazi
    Muhammad Rizwan
    BMC Chemistry, 18
  • [2] Simultaneous Determination of Polyacetylene Components in Cangzhu by Reversed-Phase High Performance Liquid Chromatography
    Chen Yanming
    Chou Guixin
    Wang Zhengtao
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2007, 25 (01) : 84 - 87
  • [3] Determination of Letrozole in Tablet Formulations by Reversed Phase High Performance Liquid Chromatography
    Ganesh, Mani
    Rajasekar, Krishanan
    Bhagiyalakshmi, Margandan
    Vinoba, Mari
    Saktimanigandan, Kavimani
    Jang, Hyun Tae
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2010, 9 (05) : 505 - 510
  • [4] Simultaneous Determination of Zidovudine and Lamivudine in Plasma Samples Using Miniaturized Homogenous Liquid-Liquid Extraction and High-Performance Liquid Chromatography
    Heydari, Rouhollah
    Lotfi, Zahra
    Ramezani, Majid
    JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 73 (11) : 1105 - 1110
  • [5] Simultaneous determination of four active pharmaceuticals in tablet dosage form by reversed-phase high performance liquid chromatography
    Bachute, Madhusudan T.
    Shanbhag, Sunil, V
    Turwale, Shankar L.
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2019, 18 (10) : 2161 - 2166
  • [6] pKa determination of oxysophocarpine by reversed - phase high performance liquid chromatography
    Huo, Huiling
    Li, Tingting
    Zhang, Lei
    SPRINGERPLUS, 2013, 2 : 1 - 5
  • [7] Determination of 8 Synthetic Food Dyes by Solid Phase Extraction and Reversed-Phase High Performance Liquid Chromatography
    Mazdeh, Fatemeh Zamani
    Khorrami, Afshin Rajabi
    Moradi-Khatoonabadi, Zhila
    EsmaeiliAftabdari, Farideh
    Ardekani, Mohammad Reza Shams
    Moghaddam, Ghazaleh
    Hajimahmoodi, Mannan
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2016, 15 (01) : 173 - 181
  • [8] Separation and Simultaneous Determination of Pb(II) and UO2(II) Using a Ligand Containing Mobile Phase in Reversed-Phase High Performance Liquid Chromatography
    Soleimani, Majid
    Morsali, Ali
    Afshar, Majid Ghahreman
    ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (06) : 2437 - 2440
  • [9] Simultaneous determination of 19 flavonoids in commercial trollflowers by using high-performance liquid chromatography and classification of samples by hierarchical clustering analysis
    Song, Zhiling
    Hashi, Yuki
    Sun, Hongyang
    Liang, Yi
    Lan, Yuexiang
    Wang, Hong
    Chen, Shizhong
    FITOTERAPIA, 2013, 91 : 272 - 279
  • [10] Simultaneous Determination of Four Fluoroquinolone Residues in Edible Chicken Tissues by Reversed-Phase High Performance Liquid Chromatography
    Dong Linlin
    Liu Yanhua
    Wang Xia
    Zhong Feng
    Peng Li
    Yue Xiuying
    Gao Lan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (03) : 285 - 288