Evaluation of the accuracy of implant placement by using implant positional guide versus freehand: a prospective clinical study

被引:5
|
作者
Huang, Lixuan [1 ,2 ,3 ]
Liu, Linfeng [1 ,2 ,3 ]
Yang, Shengtao [1 ,2 ,3 ]
Khadka, Prapti [4 ]
Zhang, Shiwen [1 ,2 ,3 ,4 ]
机构
[1] State Key Lab Oral Dis, Chengdu, Peoples R China
[2] Natl Ctr Stomatol, Chengdu, Peoples R China
[3] Natl Clin Res Ctr Oral Dis, Chengdu, Peoples R China
[4] Sichuan Univ, West China Hosp Stomatol, Dept Oral Implantol, Chengdu, Peoples R China
基金
中国国家自然科学基金;
关键词
Dental implant; Surgical guide; Implant positional guide; Implant accuracy; SURGICAL GUIDES; SURGERY; DENTISTRY;
D O I
10.1186/s40729-023-00512-z
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeThe aim of this study is to examine and compare the accuracy of implant placement using implant positional guide and freehand.Methods48 implants were placed in patients with single tooth loss with implant positional guide and freehand, respectively. The accuracy of implant placement was assessed by comparing the actual and planned position, including four parameters: coronal deviation, apical deviation, angular deviation, and vertical deviation.ResultsComparing all the variables, it has been found that the implant positional guide is more accurate than the freehand. All parameters describing in the deviation were significantly lower in the implant positional guide group than the freehand.ConclusionsThe implant positional guide can act as a practicable tool for dental implant surgery. It is a promising technology that guarantees low cost and high precision in implant surgery. However, based on the restricted evidence from clinical studies, longer follow-up periods, larger population studies, and standardized experimental studies are required.Trial registration CHICTR, ChiCTR2300071024. Registered 28 April 2023-CHICTR, ChiCTR2300071024. Registered 28 April 2023-Retrospectively registered, https://www.chictr.org.cn/showproj.html?proj=195424.ConclusionsThe implant positional guide can act as a practicable tool for dental implant surgery. It is a promising technology that guarantees low cost and high precision in implant surgery. However, based on the restricted evidence from clinical studies, longer follow-up periods, larger population studies, and standardized experimental studies are required.Trial registration CHICTR, ChiCTR2300071024. Registered 28 April 2023-CHICTR, ChiCTR2300071024. Registered 28 April 2023-Retrospectively registered, https://www.chictr.org.cn/showproj.html?proj=195424.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Evaluation of the accuracy of implant placement by using implant positional guide versus freehand: a prospective clinical study
    Lixuan Huang
    Linfeng Liu
    Shengtao Yang
    Prapti Khadka
    Shiwen Zhang
    International Journal of Implant Dentistry, 9
  • [2] Factors Influencing the Accuracy of Freehand Implant Placement: A Prospective Clinical Study
    Schnutenhaus, Sigmar
    Wagner, Marie
    Edelmann, Cornelia
    Luthardt, Ralph G.
    Rudolph, Heike
    DENTISTRY JOURNAL, 2021, 9 (05)
  • [3] Accuracy of Implant Placement with a Navigation System, a Laboratory Guide, and Freehand Drilling
    Chen, Chang-Kai
    Yuh, Da-Yo
    Huang, Ren-Yeong
    Fu, Earl
    Tsai, Cheng-Feng
    Chiang, Cheng-Yang
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (06) : 1213 - 1218
  • [4] Comparison of the accuracy of implant placement using a simple guide device and freehand surgery
    Kim, Yu-Jin
    Kim, Jungeun
    Lee, Jae-Rim
    Kim, Hee-Sun
    Sim, Hye-Young
    Lee, Ho
    Han, Yoon-Sic
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (04) : 2256 - 2261
  • [5] A retrospective study of the accuracy of template-guided versus freehand implant placement: A nonradiologic method
    Alevizakos, Vasilios
    Mitov, Gergo
    Stoetzer, Marcus
    von See, Constantin
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2019, 128 (03): : 220 - 226
  • [6] Comparison of the accuracy of implant position among freehand implant placement, static and dynamic computer-assisted implant surgery in fully edentulous patients: a non- randomized prospective study
    Jaemsuwan, S.
    Arunjaroensuk, S.
    Kaboosaya, B.
    Subbalekha, K.
    Mattheos, N.
    Pimkhaokham, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2023, 52 (02) : 264 - 271
  • [7] Accuracy of dynamic navigation compared to static surgical guides and the freehand approach in implant placement: a prospective clinical study
    Younis, Hamza
    Lv, Chengpeng
    Xu, Boya
    Zhou, Huixia
    Du, Liangzhi
    Liao, Lifan
    Zhao, Ningbo
    Long, Wen
    Elayah, Sadam Ahmed
    Chang, Xiaofeng
    He, Longlong
    HEAD & FACE MEDICINE, 2024, 20 (01)
  • [8] Comparison of the accuracy of immediate implant placement using static and dynamic computer-assisted implant system in the esthetic zone of the maxilla: a prospective study
    Feng, Yuzhang
    Su, Zhenya
    Mo, Anchun
    Yang, Xingmei
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2022, 8 (01)
  • [9] Influence of the macrodesign of an implant and the sleeve system on the accuracy of template-guided implant placement: A prospective clinical study
    Schnutenhaus, Sigmar
    Edelmann, Cornelia
    Wetzel, Martin
    Luthardt, Ralph G.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (02) : 212 - 219
  • [10] Freehand versus computer-guided implant placement: early implant failures in a case-control study
    Halabi, Dima
    Slutzkey, Gil
    Meir, Haya
    Sebaoun, Alon
    Beitlitum, Ilan
    QUINTESSENCE INTERNATIONAL, 2024, 55 (07): : 548 - 558